168 related articles for article (PubMed ID: 37335819)
1. Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats.
Ahmed Z; Ferrero A; Ren L; Vrieze TJ; Rajendran K; Favazza CP; Yu L; Bruesewitz MR; McCollough CH; Leng S
J Appl Clin Med Phys; 2023 Jul; 24(7):e14074. PubMed ID: 37335819
[TBL] [Abstract][Full Text] [Related]
2. Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience.
Rajendran K; Petersilka M; Henning A; Shanblatt E; Marsh J; Thorne J; Schmidt B; Flohr T; Fletcher J; McCollough C; Leng S
Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34271558
[TBL] [Abstract][Full Text] [Related]
3. Characterization of single- and multi-energy CT performance of an oral dark borosilicate contrast media using a clinical photon-counting-detector CT platform.
Ren L; Sun Y; Yeh B; Marsh JF; Winfree TN; Burke KA; Rajendran K; McCollough CH; Mileto A; Fletcher JG; Leng S
Med Phys; 2023 Nov; 50(11):6779-6788. PubMed ID: 37669507
[TBL] [Abstract][Full Text] [Related]
4. First Clinical Photon-counting Detector CT System: Technical Evaluation.
Rajendran K; Petersilka M; Henning A; Shanblatt ER; Schmidt B; Flohr TG; Ferrero A; Baffour F; Diehn FE; Yu L; Rajiah P; Fletcher JG; Leng S; McCollough CH
Radiology; 2022 Apr; 303(1):130-138. PubMed ID: 34904876
[TBL] [Abstract][Full Text] [Related]
5. Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT
Rajendran K; Bruesewitz M; Swicklik J; Ferrero A; Thorne J; Yu L; McCollough C; Leng S
Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38648795
[No Abstract] [Full Text] [Related]
6. Consistency of Monoenergetic Attenuation Measurements for a Clinical Dual-Source Photon-Counting Detector CT System Across Scanning Paradigms: A Phantom Study.
Yang Y; Qin L; Lin H; Xu Z; Schmidt B; Leidecker C; Yang W; Wen N; Yan F
AJR Am J Roentgenol; 2024 May; 222(5):e2330631. PubMed ID: 38323783
[No Abstract] [Full Text] [Related]
7. Metal Artifact Reduction in Photon-Counting Detector CT: Quantitative Evaluation of Artifact Reduction Techniques.
Skornitzke S; Mergen V; Biederer J; Alkadhi H; Do TD; Stiller W; Frauenfelder T; Kauczor HU; Euler A
Invest Radiol; 2024 Jun; 59(6):442-449. PubMed ID: 37812482
[TBL] [Abstract][Full Text] [Related]
8. Impact of Photon Counting Detector Technology on kV Selection and Diagnostic Workflow in CT.
Zhou W; Abdurakhimova D; Bruesewitz M; Halaweish A; McCollough CH; Leng S
Proc SPIE Int Soc Opt Eng; 2018 Mar; 10573():. PubMed ID: 30034081
[TBL] [Abstract][Full Text] [Related]
9. The first mobile photon-counting detector CT: the human images and technical performance study.
Park SJ; Park J; Kim D; Lee D; Lee CL; Bechwati I; Wu D; Gupta R; Jung J
Phys Med Biol; 2023 Apr; 68(9):. PubMed ID: 36990097
[No Abstract] [Full Text] [Related]
10. A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study.
Zhou W; Michalak GJ; Weaver JM; Gong H; Yu L; McCollough CH; Leng S
Invest Radiol; 2020 Apr; 55(4):226-232. PubMed ID: 32049691
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of Low-contrast Detectability of Photon-Counting-Detector CT Using Channelized Hotelling Observer and an ACR Accreditation Phantom.
Fan M; Zhou Z; Bruesewitz M; McCollough C; Yu L
Proc SPIE Int Soc Opt Eng; 2023 Feb; 12463():. PubMed ID: 37528865
[TBL] [Abstract][Full Text] [Related]
12. Epicardial Adipose Tissue Attenuation and Fat Attenuation Index: Phantom Study and In Vivo Measurements With Photon-Counting Detector CT.
Mergen V; Ried E; Allmendinger T; Sartoretti T; Higashigaito K; Manka R; Euler A; Alkadhi H; Eberhard M
AJR Am J Roentgenol; 2022 May; 218(5):822-829. PubMed ID: 34877869
[No Abstract] [Full Text] [Related]
13. Technical performance of a dual-energy CT system with a novel deep-learning based reconstruction process: Evaluation using an abdomen protocol.
Oostveen LJ; Boedeker KL; Balta C; Shin D; de Lange F; Prokop M; Sechopoulos I
Med Phys; 2023 Mar; 50(3):1378-1389. PubMed ID: 36502496
[TBL] [Abstract][Full Text] [Related]
14. Multi-energy CT imaging for large patients using dual-source photon-counting detector CT.
Tao S; Marsh JF; Tao A; Michalak GJ; Rajendran K; McCollough CH; Leng S
Phys Med Biol; 2020 Aug; 65(17):17NT01. PubMed ID: 32503022
[TBL] [Abstract][Full Text] [Related]
15. Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study.
Tao S; Rajendran K; McCollough CH; Leng S
Med Phys; 2019 Sep; 46(9):4105-4115. PubMed ID: 31215659
[TBL] [Abstract][Full Text] [Related]
16. CT Number Accuracy and Association With Object Size: A Phantom Study Comparing Energy-Integrating Detector CT and Deep Silicon Photon-Counting Detector CT.
Salyapongse AM; Rose SD; Pickhardt PJ; Lubner MG; Toia GV; Bujila R; Yin Z; Slavic S; Szczykutowicz TP
AJR Am J Roentgenol; 2023 Oct; 221(4):539-547. PubMed ID: 37255042
[No Abstract] [Full Text] [Related]
17. Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.
Leng S; Zhou W; Yu Z; Halaweish A; Krauss B; Schmidt B; Yu L; Kappler S; McCollough C
Phys Med Biol; 2017 Aug; 62(17):7216-7232. PubMed ID: 28726669
[TBL] [Abstract][Full Text] [Related]
18. Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter.
Rajendran K; Voss BA; Zhou W; Tao S; DeLone DR; Lane JI; Weaver JM; Carlson ML; Fletcher JG; McCollough CH; Leng S
Invest Radiol; 2020 Feb; 55(2):91-100. PubMed ID: 31770297
[TBL] [Abstract][Full Text] [Related]
19. Metal artifact reduction and tumor detection using photon-counting multi-energy computed tomography.
Lee CL; Park J; Nam S; Choi J; Choi Y; Lee S; Lee KY; Cho M
PLoS One; 2021; 16(3):e0247355. PubMed ID: 33667250
[TBL] [Abstract][Full Text] [Related]
20. Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom.
Holmes TW; Yin Z; Stevens GM; Slavic S; Okerlund DR; Maltz JS; Pourmorteza A
J Cardiovasc Comput Tomogr; 2023; 17(5):341-344. PubMed ID: 37567802
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]