These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 37339046)

  • 21. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
    Ramaekers P; Ries M; Moonen CT; de Greef M
    Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quantitative measurement and real-time tracking of high intensity focused ultrasound using phase-sensitive optical coherence tomography: Feasibility study.
    Le N; Song S; Nabi G; Wang R; Huang Z
    Int J Hyperthermia; 2016 Sep; 32(6):713-22. PubMed ID: 27380284
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Frequency-Domain Robust PCA for Real-Time Monitoring of HIFU Treatment.
    Yang K; Li Q; Xu J; Tang MX; Wang Z; Tsui PH; Zhou X
    IEEE Trans Med Imaging; 2024 Aug; 43(8):3001-3012. PubMed ID: 38578852
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Pulse compression technique for simultaneous HIFU surgery and ultrasonic imaging: a preliminary study.
    Jeong JS; Chang JH; Shung KK
    Ultrasonics; 2012 Aug; 52(6):730-9. PubMed ID: 22356771
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A beamforming study for implementation of vibro-acoustography with a 1.75-D array transducer.
    Urban MW; Chalek C; Haider B; Thomenius KE; Fatemi M; Alizad A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Mar; 60(3):535-51. PubMed ID: 23475919
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Localized elasticity measurement for detection of coagulation during HIFU therapy.
    Aoyagia R; Nakamura H; Azuma T; Yoshinaka K; Takeuchi H; Fujiwara K; Itani K; Sasaki A; Takagi S; Matsumoto Y
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6273-6. PubMed ID: 24111174
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Passive Elastography for Clinical HIFU Lesion Detection.
    Payen T; Crouzet S; Guillen N; Chen Y; Chapelon JY; Lafon C; Catheline S
    IEEE Trans Med Imaging; 2024 Apr; 43(4):1594-1604. PubMed ID: 38109239
    [TBL] [Abstract][Full Text] [Related]  

  • 28. 3D synthetic aperture imaging with a therapeutic spherical random phased array for transcostal applications.
    Zubair M; Dickinson RJ
    Phys Med Biol; 2021 Feb; 66(3):035024. PubMed ID: 33276351
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Fast and Selective Ablation of Liver Tumors by High-Intensity Focused Ultrasound Using a Toroidal Transducer Guided by Ultrasound Imaging: The Results of Animal Experiments.
    Battais A; Barrère V; N'Djin WA; Dupré A; Rivoire M; Melodelima D
    Ultrasound Med Biol; 2020 Dec; 46(12):3286-3295. PubMed ID: 32891425
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System.
    Li K; Bai J; Chen Y; Ji X
    J Vis Exp; 2019 Mar; (145):. PubMed ID: 30907874
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Strongly Focused HIFU Transducers With Simultaneous Optical Observation for Treatment of Skin at 20 MHz.
    Zawada T; Bove T
    Ultrasound Med Biol; 2022 Jul; 48(7):1309-1327. PubMed ID: 35410743
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of an MRI-Compatible High-Intensity Focused Ultrasound Phased Array Transducer Dedicated for Breast Tumor Treatment.
    Kuo LW; Chiu LC; Lin WL; Chen JJ; Dong GC; Chen SF; Chen GS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Aug; 65(8):1423-1432. PubMed ID: 29993540
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU): Technical Background and Overview of Current Clinical Applications (Part 1).
    Siedek F; Yeo SY; Heijman E; Grinstein O; Bratke G; Heneweer C; Puesken M; Persigehl T; Maintz D; Grüll H
    Rofo; 2019 Jun; 191(6):522-530. PubMed ID: 30630200
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An acoustic backscatter-based method for localization of lesions induced by high-intensity focused ultrasound.
    Zheng X; Vaezy S
    Ultrasound Med Biol; 2010 Apr; 36(4):610-22. PubMed ID: 20211516
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Feasibility study on photoacoustic guidance for high-intensity focused ultrasound-induced hemostasis.
    Nguyen VP; Kim J; Ha KL; Oh J; Kang HW
    J Biomed Opt; 2014; 19(10):105010. PubMed ID: 25354118
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An image-guided high intensity focused ultrasound device for uterine fibroids treatment.
    Chan AH; Fujimoto VY; Moore DE; Martin RW; Vaezy S
    Med Phys; 2002 Nov; 29(11):2611-20. PubMed ID: 12462728
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluating HIFU-mediated local drug release using thermal strain imaging: Phantom and preliminary in-vivo studies.
    Lee FF; He Q; Gao J; Pan A; Sun S; Liang X; Luo J
    Med Phys; 2019 Sep; 46(9):3864-3876. PubMed ID: 31314917
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ultrasound image based visual servoing for moving target ablation by high intensity focused ultrasound.
    Seo J; Koizumi N; Mitsuishi M; Sugita N
    Int J Med Robot; 2017 Dec; 13(4):. PubMed ID: 27995752
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Real-time monitoring of HIFU treatment using pulse inversion.
    Song JH; Yoo Y; Song TK; Chang JH
    Phys Med Biol; 2013 Aug; 58(15):5333-50. PubMed ID: 23863761
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dual concentric-sectored HIFU transducer with phase-shifted ultrasound excitation for expanded necrotic region: a simulation study.
    Jeong J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 May; 60(5):924-31. PubMed ID: 23661126
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.