These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 3733941)

  • 1. Rapid cation-exchange chromatography of hemoglobins and other proteins.
    Burke DJ; Duncan JK; Siebert C; Ott GS
    J Chromatogr; 1986 May; 359():533-40. PubMed ID: 3733941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-performance liquid chromatography of human hemoglobins on a new cation exchanger.
    Ou CN; Buffone GJ; Reimer GL; Alpert AJ
    J Chromatogr; 1983 Aug; 266():197-205. PubMed ID: 6630348
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Separation of hemoglobins F, Fac, S, C, A1c and determination of hemoglobin F using high performance liquid chromatography].
    Pic P; Ducrocq R; Girot R
    Ann Biol Clin (Paris); 1994; 52(2):129-32. PubMed ID: 7528482
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cation-exchange high-performance liquid chromatography of proteins on poly(aspartic acid)-silica.
    Alpert AJ
    J Chromatogr; 1983 Aug; 266():23-37. PubMed ID: 6630351
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An automated "high-pressure" liquid-chromatographic assay for hemoglobin A1c.
    Ellis G; Diamandis EP; Giesbrecht EE; Daneman D; Allen LC
    Clin Chem; 1984 Nov; 30(11):1746-52. PubMed ID: 6488517
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-performance liquid chromatographic separation of biological macromolecules on new silica-based ion exchangers.
    Ueda T; Ishida Y
    J Chromatogr; 1987 Jan; 386():273-82. PubMed ID: 3031097
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Packing materials suitable for rapid, analytical, low-pressure chromatography of haemoglobins on midget columns.
    Ersser RS; Barlow GB; Drew RG; Hjelm M
    Biomed Chromatogr; 1986 Aug; 1(4):183-8. PubMed ID: 2465798
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effects of abnormal hemoglobins on a new microcolumn method to determine hemoglobin A1c.
    Davis JL; Bryan B; Simpkins H
    Ann Clin Lab Sci; 1985; 15(1):71-5. PubMed ID: 2578764
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Protein separations with induced pH gradients using cation-exchange chromatographic columns containing weak acid groups.
    Pabst TM; Antos D; Carta G; Ramasubramanyan N; Hunter AK
    J Chromatogr A; 2008 Feb; 1181(1-2):83-94. PubMed ID: 18194806
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid protein profiling with a novel anion-exchange material.
    Burke DJ; Duncan JK; Dunn LC; Cummings L; Siebert CJ; Ott GS
    J Chromatogr; 1986 Feb; 353():425-37. PubMed ID: 3700524
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Separation of asymmetrical hybrid hemoglobins by anaerobic cation-exchange high-performance liquid chromatography.
    Ip CY; Asakura T
    Anal Biochem; 1984 Jun; 139(2):427-31. PubMed ID: 6476379
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High-performance cation-exchange chromatography of proteins.
    Gupta S; Pfannkoch E; Regnier FE
    Anal Biochem; 1983 Jan; 128(1):196-201. PubMed ID: 6303152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation of hemoglobin types by cation-exchange high-performance liquid chromatography.
    Gupta SP; Hanash SM
    Anal Biochem; 1983 Oct; 134(1):117-21. PubMed ID: 6660481
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cation-exchange, high-performance liquid chromatographic determination of hemoglobin A1c.
    Toren EC; Vacik DN; Mockridge PB
    J Chromatogr; 1983 Aug; 266():207-12. PubMed ID: 6630349
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High performance liquid chromatography of hemoglobins: factors affecting resolution.
    Hanash SM; Kavadella M; Amanullah A; Scheller K; Bunnell K
    Prog Clin Biol Res; 1981; 60():53-67. PubMed ID: 6169093
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemoglobin A1c by HPLC with the Pharmacia Mono S HR 5/N cation-exchange column: influence of sample protein load on optimal chromatographic conditions.
    Philcox JC; Haywood MR; Rofe AM
    Clin Chem; 1992 Aug; 38(8 Pt 1):1488-90. PubMed ID: 1379526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Synthesis of a non-porous, polystyrene-based strong anion-exchange packing material and its application to fast high-performance liquid chromatography of proteins.
    Rounds MA; Regnier FE
    J Chromatogr; 1988 Jun; 443():73-83. PubMed ID: 3170696
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preparation of a candidate primary reference material for the international standardisation of HbA1c determinations.
    Finke A; Kobold U; Hoelzel W; Weykamp C; Miedema K; Jeppsson JO
    Clin Chem Lab Med; 1998 May; 36(5):299-308. PubMed ID: 9676387
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Isolation of glycosylated hemoglobins by a combination of ion-exchange and gel-filtration chromatographies: a pilot study.
    Lowrey CH; Soeldner JS
    Anal Biochem; 1986 May; 154(2):424-30. PubMed ID: 3728961
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved rapid procedure for simultaneous determinations of hemoglobins A1a, A1b, A1c, F, C, and S, with indication for acetylation or carbamylation by cation-exchange liquid chromatography.
    Brunnekreeft JW; Eidhof HH
    Clin Chem; 1993 Dec; 39(12):2514-8. PubMed ID: 7504594
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.