These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 37342601)

  • 21. Chirp phantom for MTF calculations. A study of its precision in noisy environments.
    González-López A
    Phys Med; 2018 Apr; 48():65-71. PubMed ID: 29728231
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Error of the slanted edge method for measuring the modulation transfer function of imaging systems.
    Xie X; Fan H; Wang H; Wang Z; Zou N
    Appl Opt; 2018 Mar; 57(7):B83-B91. PubMed ID: 29521991
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of edge analysis techniques for the determination of the MTF of digital radiographic systems.
    Samei E; Buhr E; Granfors P; Vandenbroucke D; Wang X
    Phys Med Biol; 2005 Aug; 50(15):3613-25. PubMed ID: 16030386
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [A method of measuring presampled modulation transfer function using a rationalized approximation of geometrical edge slope].
    Honda M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Apr; 70(4):346-58. PubMed ID: 24759215
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of the modulation transfer function using the edge method: influence of scattered radiation.
    Neitzel U; Buhr E; Hilgers G; Granfors PR
    Med Phys; 2004 Dec; 31(12):3485-91. PubMed ID: 15651631
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image.
    Buhr E; Günther-Kohfahl S; Neitzel U
    Med Phys; 2003 Sep; 30(9):2323-31. PubMed ID: 14528954
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Modulation transfer function (MTF) evaluation for x-ray phase imaging system employing attenuation masks.
    Havariyoun G; Massimi L; Hagen C; Endrizzi M; Olivo A
    Phys Med Biol; 2023 Apr; 68(9):. PubMed ID: 36996845
    [No Abstract]   [Full Text] [Related]  

  • 28. Measurements of system sharpness for two digital breast tomosynthesis systems.
    Marshall NW; Bosmans H
    Phys Med Biol; 2012 Nov; 57(22):7629-50. PubMed ID: 23123601
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Method for estimating modulation transfer function from sample images.
    Saiga R; Takeuchi A; Uesugi K; Terada Y; Suzuki Y; Mizutani R
    Micron; 2018 Feb; 105():64-69. PubMed ID: 29179010
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of an algorithm for the assessment of the MTF using an edge method.
    Greer PB; van Doorn T
    Med Phys; 2000 Sep; 27(9):2048-59. PubMed ID: 11011732
    [TBL] [Abstract][Full Text] [Related]  

  • 31. MTF Measurement by Slanted-Edge Method Based on Improved Zernike Moments.
    Zhang S; Wang F; Wu X; Gao K
    Sensors (Basel); 2023 Jan; 23(1):. PubMed ID: 36617108
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quantification of scattered radiation in projection mammography: four practical methods compared.
    Salvagnini E; Bosmans H; Struelens L; Marshall NW
    Med Phys; 2012 Jun; 39(6):3167-80. PubMed ID: 22755701
    [TBL] [Abstract][Full Text] [Related]  

  • 33. On-Orbit Modulation Transfer Function Estimation Based on the Refined Image Kernel.
    Wang Y; Zhong X; Qu Z; Li L; Wu S; Zeng C
    Sensors (Basel); 2023 Apr; 23(9):. PubMed ID: 37177565
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors.
    Gislason-Lee AJ; Tunstall CM; Kengyelics SK; Cowen AR; Davies AG
    Med Phys; 2015 Aug; 42(8):4423-7. PubMed ID: 26233172
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Proposal and verification of presampled MTF measurement by simple analysis using the edge method].
    Higashide R; Ichikawa K; Kunitomo H; Sawada M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2008 Apr; 64(4):417-25. PubMed ID: 18451598
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A method for measuring the presampled MTF of digital radiographic systems using an edge test device.
    Samei E; Flynn MJ; Reimann DA
    Med Phys; 1998 Jan; 25(1):102-13. PubMed ID: 9472832
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology.
    Samei E; Richard S
    Med Phys; 2015 Jan; 42(1):314-23. PubMed ID: 25563271
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance of a new star-bar phantom designed for MTF calculations in x-ray imaging systems.
    González-López A; Campos-Morcillo PA; Vera-Sánchez JA; Ruiz-Morales C
    Med Phys; 2020 Oct; 47(10):4949-4955. PubMed ID: 32750161
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Theory, method, and test tools for determination of 3D MTF characteristics in cone-beam CT.
    Wu P; Boone JM; Hernandez AM; Mahesh M; Siewerdsen JH
    Med Phys; 2021 Jun; 48(6):2772-2789. PubMed ID: 33660261
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Edge-based modulation transfer function measurement method using a variable oversampling ratio.
    Masaoka K
    Opt Express; 2021 Nov; 29(23):37628-37638. PubMed ID: 34808831
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.