These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 37343400)

  • 1. Ultrafast RNA extraction-free SARS-CoV-2 detection by direct RT-PCR using a rapid thermal cycling approach.
    Struijk R; van den Ouden A; Louwerse J; Čurová K; Burggrave R; McNally B; de Groot T; Mulder B; de Vos G
    Diagn Microbiol Infect Dis; 2023 Sep; 107(1):115975. PubMed ID: 37343400
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements.
    Visseaux B; Collin G; Houhou-Fidouh N; Le Hingrat Q; Ferré VM; Damond F; Ichou H; Descamps D; Charpentier C
    J Virol Methods; 2021 May; 291():114086. PubMed ID: 33577957
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of a novel antigen detection test with reverse transcription polymerase chain reaction assay for laboratory diagnosis of SARS-CoV-2 infection.
    Cirit OS; Mutlu E; Sancak B; Kocagöz T; Can Ö; Çicek C; Arzu Sayiner A; Appak Ö; Uyar NY; Külah C; Çiçek AÇ; Özgümüs OB; Ay Altintop Y; Saatçi E; Karsligil T; Zer Y; Özen NS; Çekin Y; Karahan ZC; Evren E; Karakoç AE; Orhan SG; Mutlu D; Bozdemir T; Çayci YT; Çinar C; Tasbakan M; Mert M; Çinar E; Kutsoylu OÖE; Kocagöz S; Ertürk A; Çelik I; Mete AÖ; Günalp Eneyli M; Akdemir I; Karakök T; Inan D; Atilla A; Taflan ŞO; Yörük KE
    Infection; 2023 Feb; 51(1):91-96. PubMed ID: 35513690
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detection of SARS-CoV-2 RNA by direct RT-qPCR on nasopharyngeal specimens without extraction of viral RNA.
    Hasan MR; Mirza F; Al-Hail H; Sundararaju S; Xaba T; Iqbal M; Alhussain H; Yassine HM; Perez-Lopez A; Tang P
    PLoS One; 2020; 15(7):e0236564. PubMed ID: 32706827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Emergency SARS-CoV-2 variants of concern: rapidly direct RT-qPCR detection without RNA extraction, clinical comparison, cost-effective, and high-throughput.
    Yang BH; Chung HY; Kao LT; Jian MJ; Chang CK; Lin JC; Yeh KM; Chen CW; Yang YS; Hsieh SS; Tang SH; Perng CL; Chang FY; Shang HS
    Aging (Albany NY); 2022 Jun; 14(11):4624-4633. PubMed ID: 35657641
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated sample-to-answer centrifugal microfluidic system for rapid molecular diagnostics of SARS-CoV-2.
    Malic L; Brassard D; Da Fonte D; Nassif C; Mounier M; Ponton A; Geissler M; Shiu M; Morton KJ; Veres T
    Lab Chip; 2022 Aug; 22(17):3157-3171. PubMed ID: 35670202
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extraction-free SARS-CoV-2 detection by rapid RT-qPCR universal for all primary respiratory materials.
    Lübke N; Senff T; Scherger S; Hauka S; Andrée M; Adams O; Timm J; Walker A
    J Clin Virol; 2020 Sep; 130():104579. PubMed ID: 32795959
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Value of swab types and collection time on SARS-COV-2 detection using RT-PCR assay.
    Liu M; Li Q; Zhou J; Ai W; Zheng X; Zeng J; Liu Y; Xiang X; Guo R; Li X; Wu X; Xu H; Jiang L; Zhang H; Chen J; Tian L; Luo J; Luo C
    J Virol Methods; 2020 Dec; 286():113974. PubMed ID: 32949663
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of High-Sensitivity Severe Acute Respiratory Syndrome Coronavirus 2 Testing for Stool-Toward the New Normal for Fecal Microbiota Transplantation.
    Babiker A; Ingersoll JM; Adelman MW; Webster AS; Broder KJ; Stittleburg V; Waggoner JJ; Kraft CS; Woodworth MH
    Clin Transl Gastroenterol; 2021 Jun; 12(6):e00363. PubMed ID: 34106090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of COVID-19 laboratory diagnosis by commercial kits: Effectivity of RT-PCR to the RT-LAMP.
    Artik Y; Coşğun AB; Cesur NP; Hızel N; Uyar Y; Sur H; Ayan A
    J Med Virol; 2022 May; 94(5):1998-2007. PubMed ID: 34997587
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel dual multiplex real-time RT-PCR assays for the rapid detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus using the BD MAX open system.
    Chung HY; Jian MJ; Chang CK; Lin JC; Yeh KM; Chen CW; Chiu SK; Wang YH; Liao SJ; Li SY; Hsieh SS; Tsai SH; Perng CL; Yang JR; Liu MT; Chang FY; Shang HS
    Emerg Microbes Infect; 2021 Dec; 10(1):161-166. PubMed ID: 33410371
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A semi-automated, isolation-free, high-throughput SARS-CoV-2 reverse transcriptase (RT) loop-mediated isothermal amplification (LAMP) test.
    Schmidt J; Berghaus S; Blessing F; Wenzel F; Herbeck H; Blessing J; Schierack P; Rödiger S; Roggenbuck D
    Sci Rep; 2021 Nov; 11(1):21385. PubMed ID: 34725400
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization and Improvement of qPCR Detection Sensitivity of SARS-CoV-2 in Saliva.
    Ko HY; Li YT; Li YY; Chiang MT; Lee YL; Liu WC; Liao CC; Chang CS; Lin YL
    Microbiol Spectr; 2023 Jun; 11(3):e0464022. PubMed ID: 37097200
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparative study on the efficiency of commercial reverse transcriptase-Polymerase chain reaction kits for the detection of severe acute respiratory syndrome coronavirus 2 infections.
    Ramalingam G; Dhanasezhian A; Murugesan A; Saminathan G; Sivathanu L
    Indian J Public Health; 2022; 66(3):276-281. PubMed ID: 36149104
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of RT-PCR, RT-LAMP, and Antigen Quantification Assays for the Detection of SARS-CoV-2.
    Tanimoto Y; Mori A; Miyamoto S; Ito E; Arikawa K; Iwamoto T
    Jpn J Infect Dis; 2022 May; 75(3):249-253. PubMed ID: 34588370
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extraction-Free Rapid Cycle Quantitative RT-PCR and Extreme RT-PCR for SARS-CoV-2 Virus Detection.
    Lownik JC; Way GW; Farrar JS; Martin RK
    J Mol Diagn; 2021 Dec; 23(12):1671-1679. PubMed ID: 34454108
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-Throughput COVID-19 Testing of Naso-Oropharyngeal Swabs Using a Sensitive Extraction-Free Sample Preparation Method.
    Pryce TM; Haygarth EJ; Bordessa J; Jeffery CT; Kay ID; Flexman JP; Boan PA
    Microbiol Spectr; 2022 Aug; 10(4):e0135822. PubMed ID: 35950846
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extraction-free RT-LAMP to detect SARS-CoV-2 is less sensitive but highly specific compared to standard RT-PCR in 101 samples.
    Schellenberg JJ; Ormond M; Keynan Y
    J Clin Virol; 2021 Mar; 136():104764. PubMed ID: 33636553
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of filter paper to transport oro/nasopharyngeal samples to detect SARS-CoV-2 by RT-qPCR.
    Dos Santos Carneiro M; Volpato FCZ; Wink PL; Pereira DC; Giordani L; Barth AL
    J Virol Methods; 2022 Oct; 308():114587. PubMed ID: 35870670
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sensitive SARS-CoV-2 detection, air travel Covid-19 testing, variant determination and fast direct PCR detection, using ddPCR and RT-qPCR methods.
    Burjanivova T; Lukacova E; Lucansky V; Samec M; Podlesniy P; Kolkova Z; Reizigova L; Grendar M; Turyova E; Holubekova V; Malicherova B; Nosal V; Kasubova I; Dusenka R; Osinova D; Hosalova Matisova J; Dvorska D; Brany D; Dankova Z; Novakova E; Calkovska A; Halasova E
    Acta Virol; 2023; 67(1):3-12. PubMed ID: 36876506
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.