These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 37354531)

  • 1. New application of saline contrast-enhanced electrical impedance tomography method for right ventriculography besides lung perfusion: detection of right-to-left intracardiac shunt.
    He H; Wang N; Zhang M; Jiang J; Cui N; Frerichs I; Long Y; Zhao Z
    QJM; 2023 Jun; ():. PubMed ID: 37354531
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lung Perfusion Assessment by Bedside Electrical Impedance Tomography in Critically Ill Patients.
    Xu M; He H; Long Y
    Front Physiol; 2021; 12():748724. PubMed ID: 34721072
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three broad classifications of acute respiratory failure etiologies based on regional ventilation and perfusion by electrical impedance tomography: a hypothesis-generating study.
    He H; Chi Y; Long Y; Yuan S; Zhang R; Yang Y; Frerichs I; Möller K; Fu F; Zhao Z
    Ann Intensive Care; 2021 Aug; 11(1):134. PubMed ID: 34453622
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrical impedance tomography to aid in the identification of hypoxemia etiology: Massive atelectasis or pneumothorax? A case report.
    Zhou R; He C; Chi Y; Yuan S; Tang B; Li Z; Li Q; He H; Long Y
    Front Med (Lausanne); 2022; 9():970087. PubMed ID: 36117985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of right-to-left shunt flow in atrial septal defect by transesophageal color and pulsed Doppler echocardiography.
    Oki T; Iuchi A; Fukuda N; Tabata T; Hayashi M; Tanimoto M; Manabe K; Kageji Y; Sasaki M; Hama M
    J Am Soc Echocardiogr; 1994; 7(5):506-15. PubMed ID: 7986548
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Right-to-left shunt detection sensitivity with air-saline and air-succinil gelatin transcranial Doppler.
    Puledda F; Toscano M; Pieroni A; Veneroso G; Di Piero V; Vicenzini E
    Int J Stroke; 2016 Feb; 11(2):229-38. PubMed ID: 26783315
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of color flow imaging and peripheral venous saline contrast during transesophageal echocardiography to evaluate right-to-left shunt at the atrial level.
    Waggoner AD; Dávila-Román VG; Hopkins WE; Pérez JE; Barzilai B
    Echocardiography; 1993 Jan; 10(1):59-66. PubMed ID: 10148116
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Regional Lung Perfusion Analysis in Experimental ARDS by Electrical Impedance and Computed Tomography.
    Kircher M; Elke G; Stender B; Hernandez Mesa M; Schuderer F; Dossel O; Fuld MK; Halaweish AF; Hoffman EA; Weiler N; Frerichs I
    IEEE Trans Med Imaging; 2021 Jan; 40(1):251-261. PubMed ID: 32956046
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of relative lung perfusion with electrical impedance and positron emission tomography: an experimental comparative study in pigs.
    Bluth T; Kiss T; Kircher M; Braune A; Bozsak C; Huhle R; Scharffenberg M; Herzog M; Roegner J; Herzog P; Vivona L; Millone M; Dössel O; Andreeff M; Koch T; Kotzerke J; Stender B; Gama de Abreu M
    Br J Anaesth; 2019 Aug; 123(2):246-254. PubMed ID: 31160064
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Two-dimensional Doppler color flow mapping in congenital heart disease.
    Ritter SB
    Clin Cardiol; 1986 Dec; 9(12):591-6. PubMed ID: 3780074
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Detection of right-to-left shunt flow in atrial septal defect using transesophageal color and pulsed Doppler echocardiography].
    Hayashi M; Oki T; Iuchi A; Ogawa S; Kageji Y; Hosoi K; Tanimoto M; Fukuda K; Tabata T; Fukuda N
    J Cardiol; 1994; 24(3):227-36. PubMed ID: 8207638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of changes in distribution of lung perfusion by electrical impedance tomography.
    Frerichs I; Pulletz S; Elke G; Reifferscheid F; Schadler D; Scholz J; Weiler N
    Respiration; 2009; 77(3):282-91. PubMed ID: 19147986
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid dynamic bedside assessment of pulmonary perfusion defect by electrical impedance tomography in a patient with acute massive pulmonary embolism.
    Yuan S; He H; Long Y; Chi Y; Frerichs I; Zhao Z
    Pulm Circ; 2021; 11(1):2045894020984043. PubMed ID: 33532059
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Importance of an adequately performed Valsalva maneuver for detecting a right-to-left shunt indicating foramen ovale reopening.
    Wei D; Ju Y
    J Ultrasound Med; 2015 May; 34(5):879-83. PubMed ID: 25911721
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detecting and Quantifying Residual Intracardiac Shunts Using Oximetric Step-Up Methods: A Prospective Observational Study.
    Bhende VV; Sharma TS; Sharma AS; Kumar A; Patel NP; Majmudar HP; Patel MR; Patel KA; Panesar G; Soni K; Dhami KB; Pathan SR; Parmar DM; Nerurkar P
    Cureus; 2023 Jan; 15(1):e33942. PubMed ID: 36694858
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of electrical impedance cardiography for measuring cardiac output in children with congenital heart defects.
    Miles DS; Gotshall RW; Golden JC; Tuuri DT; Beekman RH; Dillon T
    Am J Cardiol; 1988 Mar; 61(8):612-6. PubMed ID: 3344687
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts.
    Nemec JJ; Marwick TH; Lorig RJ; Davison MB; Chimowitz MI; Litowitz H; Salcedo EE
    Am J Cardiol; 1991 Dec; 68(15):1498-502. PubMed ID: 1746433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive pulsed Doppler echocardiographic detection of the direction of shunt flow in patients with atrial septal defect: usefulness of the right parasternal approach.
    Minagoe S; Tei C; Kisanuki A; Arikawa K; Nakazono Y; Yoshimura H; Kashima T; Tanaka H
    Circulation; 1985 Apr; 71(4):745-53. PubMed ID: 3971543
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of intracardiac shunt flow in atrial septal defect using a real-time two-dimensional color-coded Doppler flow imaging system and comparison with contrast two-dimensional echocardiography.
    Suzuki Y; Kambara H; Kadota K; Tamaki S; Yamazato A; Nohara R; Osakada G; Kawai C
    Am J Cardiol; 1985 Aug; 56(4):347-50. PubMed ID: 4025176
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of bolus- and filtering-based EIT measures of lung perfusion in an animal model.
    Stowe S; Boyle A; Sage M; See W; Praud JP; Fortin-Pellerin É; Adler A
    Physiol Meas; 2019 Jun; 40(5):054002. PubMed ID: 30965314
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]