These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
156 related articles for article (PubMed ID: 37356392)
1. SARS CoV-2 infection screening via the exhaled breath fingerprint obtained by FTIR spectroscopic gas-phase analysis. A proof of concept. Glöckler J; Mizaikoff B; Díaz de León-Martínez L Spectrochim Acta A Mol Biomol Spectrosc; 2023 Dec; 302():123066. PubMed ID: 37356392 [TBL] [Abstract][Full Text] [Related]
2. Detection of SARS-CoV-2 infection by exhaled breath spectral analysis: Introducing a ready-to-use point-of-care mass screening method. Shlomo IB; Frankenthal H; Laor A; Greenhut AK EClinicalMedicine; 2022 Mar; 45():101308. PubMed ID: 35224472 [TBL] [Abstract][Full Text] [Related]
3. Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors. Perez-Guaita D; Kokoric V; Wilk A; Garrigues S; Mizaikoff B J Breath Res; 2014 Jun; 8(2):026003. PubMed ID: 24848160 [TBL] [Abstract][Full Text] [Related]
4. Exhaled nitric oxide detection for diagnosis of COVID-19 in critically ill patients. Exline MC; Stanacevic M; Bowman AS; Gouma PI PLoS One; 2021; 16(10):e0257644. PubMed ID: 34710098 [TBL] [Abstract][Full Text] [Related]
5. Hybrid Analytical Platform Based on Field-Asymmetric Ion Mobility Spectrometry, Infrared Sensing, and Luminescence-Based Oxygen Sensing for Exhaled Breath Analysis. Hagemann LT; Repp S; Mizaikoff B Sensors (Basel); 2019 Jun; 19(12):. PubMed ID: 31212768 [TBL] [Abstract][Full Text] [Related]
6. Experimental setup and analytical methods for the non-invasive determination of volatile organic compounds, formaldehyde and NOx in exhaled human breath. Riess U; Tegtbur U; Fauck C; Fuhrmann F; Markewitz D; Salthammer T Anal Chim Acta; 2010 Jun; 669(1-2):53-62. PubMed ID: 20510903 [TBL] [Abstract][Full Text] [Related]
7. COVID-19 screening using breath-borne volatile organic compounds. Chen H; Qi X; Zhang L; Li X; Ma J; Zhang C; Feng H; Yao M J Breath Res; 2021 Oct; 15(4):. PubMed ID: 34624875 [TBL] [Abstract][Full Text] [Related]
8. A rapid method for breath analysis in cystic fibrosis patients. Kramer R; Sauer-Heilborn A; Welte T; Guzman CA; Höfle MG; Abraham WR Eur J Clin Microbiol Infect Dis; 2015 Apr; 34(4):745-51. PubMed ID: 25431363 [TBL] [Abstract][Full Text] [Related]
9. Identification of a characteristic VOCs pattern in the exhaled breath of post-COVID subjects: are metabolic alterations induced by the infection still detectable? Di Gilio A; Palmisani J; Picciariello A; Zambonin C; Aresta A; De Vietro N; Franchini SA; Ventrella G; Nisi MR; Licen S; Barbieri P; Altomare DF; de Gennaro G J Breath Res; 2023 Jul; 17(4):. PubMed ID: 37379826 [TBL] [Abstract][Full Text] [Related]
10. Perylene diimide-POSS network for semi selective solid-phase microextraction of lung cancer biomarkers in exhaled breath. Soufi G; Bagheri H; Yeganeh Rad L; Minaeian S Anal Chim Acta; 2022 Mar; 1198():339550. PubMed ID: 35190135 [TBL] [Abstract][Full Text] [Related]
11. Breath testing for SARS-CoV-2 infection. Myers R; Ruszkiewicz DM; Meister A; Bartolomeu C; Atkar-Khattra S; Thomas CLP; Lam S EBioMedicine; 2023 Jun; 92():104584. PubMed ID: 37121096 [TBL] [Abstract][Full Text] [Related]
12. A feasibility study of Covid-19 detection using breath analysis by high-pressure photon ionization time-of-flight mass spectrometry. Zhang P; Ren T; Chen H; Li Q; He M; Feng Y; Wang L; Huang T; Yuan J; Deng G; Lu H J Breath Res; 2022 Sep; 16(4):. PubMed ID: 36052728 [TBL] [Abstract][Full Text] [Related]
13. Fiber-Optic Bio-sniffer (Biochemical Gas Sensor) Using Reverse Reaction of Alcohol Dehydrogenase for Exhaled Acetaldehyde. Iitani K; Chien PJ; Suzuki T; Toma K; Arakawa T; Iwasaki Y; Mitsubayashi K ACS Sens; 2018 Feb; 3(2):425-431. PubMed ID: 29380601 [TBL] [Abstract][Full Text] [Related]
14. On the importance of accurate quantification of individual volatile metabolites in exhaled breath. Smith D; Španěl P J Breath Res; 2017 Nov; 11(4):047106. PubMed ID: 28635619 [TBL] [Abstract][Full Text] [Related]
15. Switchable sniff-cam (gas-imaging system) based on redox reactions of alcohol dehydrogenase for ethanol and acetaldehyde in exhaled breath. Iitani K; Hayakawa Y; Toma K; Arakawa T; Mitsubayashi K Talanta; 2019 May; 197():249-256. PubMed ID: 30771931 [TBL] [Abstract][Full Text] [Related]
16. Exploratory study on noninvasive biomarker of silicosis in exhaled breath by solid-phase microextraction-gas chromatography-mass spectrometry analysis. Yi Z; Dong S; Wang X; Xu M; Li Y; Xie L Int Arch Occup Environ Health; 2023 Aug; 96(6):857-868. PubMed ID: 37067574 [TBL] [Abstract][Full Text] [Related]
17. Assessment of an e-nose performance for the detection of COVID-19 specific biomarkers. Ghazaly C; Biletska K; Thevenot EA; Devillier P; Naline E; Grassin-Delyle S; Scorsone E J Breath Res; 2023 Feb; 17(2):. PubMed ID: 36749983 [TBL] [Abstract][Full Text] [Related]
18. Exhaled breath testing - A tool for the clinician and researcher. Davis MD; Fowler SJ; Montpetit AJ Paediatr Respir Rev; 2019 Feb; 29():37-41. PubMed ID: 29921519 [TBL] [Abstract][Full Text] [Related]