These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

56 related articles for article (PubMed ID: 3736306)

  • 1. Declotting closed suction systems.
    Alessi DM; Berke G
    Laryngoscope; 1986 Aug; 96(8):917-8. PubMed ID: 3736306
    [No Abstract]   [Full Text] [Related]  

  • 2. Open and closed endotracheal suction systems in mechanically ventilated intensive care patients: a meta-analysis.
    Jongerden IP; Rovers MM; Grypdonck MH; Bonten MJ
    Crit Care Med; 2007 Jan; 35(1):260-70. PubMed ID: 17133187
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Breakage of Redivac suction drains.
    Paton RW; Beggs FD; Kark AE
    Ann R Coll Surg Engl; 1985 Mar; 67(2):122-3. PubMed ID: 3977252
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical drainage.
    Smith SR; Gilmore OJ
    Br J Hosp Med; 1985 Jun; 33(6):308, 311, 314-15. PubMed ID: 4016395
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Healthco disposable saliva ejectors: dislodged tips.
    Health Devices; 1993 Apr; 22(4):205-6. PubMed ID: 8244747
    [No Abstract]   [Full Text] [Related]  

  • 6. Use of vacutainer suction as a convenient method of resolving postmastectomy seromas.
    Estes NC; Glover JL
    Surg Gynecol Obstet; 1982 Oct; 155(4):561-2. PubMed ID: 7123474
    [No Abstract]   [Full Text] [Related]  

  • 7. Intermittent operation of Elekta Selector ultrasonic aspirators.
    Health Devices; 1997 Dec; 26(12):474-5. PubMed ID: 9416477
    [No Abstract]   [Full Text] [Related]  

  • 8. Implosion of a suction apparatus.
    Cozanitis DA; Karhunen U
    Anaesthesiol Reanim; 1988; 13(4):243-4. PubMed ID: 3166677
    [No Abstract]   [Full Text] [Related]  

  • 9. Hypoxia caused by a faulty Steri-cath closed suction device and use of continuous suction.
    Deakin CD; McQuillan PJ
    Br J Anaesth; 1999 Oct; 83(4):682. PubMed ID: 10673895
    [No Abstract]   [Full Text] [Related]  

  • 10. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
    El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
    Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Benefits of fibrin sealants in parotidectomy: is underflap suction drainage necessary?
    Patel MJ; Garg R; Rice DH
    Laryngoscope; 2006 Sep; 116(9):1708-9. PubMed ID: 16955010
    [No Abstract]   [Full Text] [Related]  

  • 12. Comparison of the effect of closed versus open endotracheal suction systems on the development of ventilator-associated pneumonia.
    Topeli A; Harmanci A; Cetinkaya Y; Akdeniz S; Unal S
    J Hosp Infect; 2004 Sep; 58(1):14-9. PubMed ID: 15350708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inappropriate ventilator triggering caused by an in-line suction catheter.
    Al-Khafaji A; Manning HL
    Intensive Care Med; 2002 Apr; 28(4):515-9. PubMed ID: 11967610
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preventing kinking of suction tubing of transposable electrical suction device and wall mounted vacuum units.
    Sen I; Makkar JK; Singh NP
    Paediatr Anaesth; 2007 Jun; 17(6):599-600. PubMed ID: 17498028
    [No Abstract]   [Full Text] [Related]  

  • 15. Studies on optimal conditions in surgical suction systems.
    Vällfors B; Hansson HA; Johansson G; Larsson S
    Acta Chir Scand Suppl; 1976; 474():1-36. PubMed ID: 1072564
    [No Abstract]   [Full Text] [Related]  

  • 16. Not every bulb is a rose: a functional comparison of bulb suction devices.
    Whitson BA; Richardson E; Iaizzo PA; Hess DJ
    J Surg Res; 2009 Oct; 156(2):270-3. PubMed ID: 19691976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cost-effectiveness and safety of reusable tracheal suction tubes.
    Nanta P; Senarat W; Tribuddharat C; Danchaivijitr S
    J Med Assoc Thai; 2005 Dec; 88 Suppl 10():S86-8. PubMed ID: 16850647
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Medical gas and vacuum systems. ECRI.
    Health Devices; 1994; 23(1-2):4-53. PubMed ID: 8169147
    [No Abstract]   [Full Text] [Related]  

  • 19. Knotted drainage tube: practical points in its prevention.
    Mobb GE; Lewis MH; Goodwin DP
    Ann R Coll Surg Engl; 1983 Sep; 65(5):325. PubMed ID: 6614772
    [No Abstract]   [Full Text] [Related]  

  • 20. Blood clots should be evacuated before nasal packing: the problem of the Yankauer sucker.
    Badran K
    Clin Otolaryngol; 2006 Feb; 31(1):74-5. PubMed ID: 16441810
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.