These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

300 related articles for article (PubMed ID: 3736507)

  • 1. Monte Carlo studies of x-ray scattering in transmission diagnostic radiology.
    Barnea G; Dick CE
    Med Phys; 1986; 13(4):490-5. PubMed ID: 3736507
    [TBL] [Abstract][Full Text] [Related]  

  • 2. X-ray scatter data for diagnostic radiology.
    Dick CE; Soares CG; Motz JW
    Phys Med Biol; 1978 Nov; 23(6):1076-85. PubMed ID: 733896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo simulation of diagnostic x-ray scatter.
    Papin PJ; Rielly PS
    Med Phys; 1988; 15(6):909-14. PubMed ID: 3237150
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies.
    Chan HP; Doi K
    Med Phys; 1985; 12(2):152-65. PubMed ID: 4000070
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The spectrum and angular distribution of x rays scattered from a water phantom.
    Cheng CW; Taylor KW; Holloway AF
    Med Phys; 1995 Aug; 22(8):1235-45. PubMed ID: 7476709
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo calculations of x-ray scatter data for diagnostic radiology.
    Kalender W
    Phys Med Biol; 1981 Sep; 26(5):835-49. PubMed ID: 7291304
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Monte Carlo study of multiple scatter effects in Compton scatter densitometry.
    Speller RD; Horrocks JA
    Med Phys; 1988; 15(5):707-12. PubMed ID: 3185406
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Some properties of photon scattering in water phantoms in diagnostic radiology.
    Chan HP; Doi K
    Med Phys; 1986; 13(6):824-30. PubMed ID: 3796478
    [TBL] [Abstract][Full Text] [Related]  

  • 9. X-ray scatter background signals in transmission radiography.
    Motz JW; Dick CE
    Med Phys; 1975; 2(5):259-67. PubMed ID: 1186632
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of the diagnostic radiological index of protection to protective garments.
    Pasciak AS; Jones AK; Wagner LK
    Med Phys; 2015 Feb; 42(2):653-662. PubMed ID: 28102605
    [TBL] [Abstract][Full Text] [Related]  

  • 11. X-ray scatter in megavoltage transmission radiography: physical characteristics and influence on image quality.
    Jaffray DA; Battista JJ; Fenster A; Munro P
    Med Phys; 1994 Jan; 21(1):45-60. PubMed ID: 8164588
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.
    Kim J; Hill R; Claridge Mackonis E; Kuncic Z
    Phys Med Biol; 2010 Feb; 55(3):783-97. PubMed ID: 20071763
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.
    Platten DJ
    J Radiol Prot; 2014 Jun; 34(2):445-56. PubMed ID: 24894101
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV-18 MeV.
    Hermida-López M; Lüdemann L; Flühs A; Brualla L
    Med Phys; 2014 Nov; 41(11):112103. PubMed ID: 25370654
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simulated scatter performance of an inverse-geometry dedicated breast CT system.
    Bhagtani R; Schmidt TG
    Med Phys; 2009 Mar; 36(3):788-96. PubMed ID: 19378739
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiation dose in diagnostic radiology: Monte Carlo simulation studies.
    Chan HP; Doi K
    Med Phys; 1984; 11(4):480-90. PubMed ID: 6482844
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of a computer model using the EGS4 simulation code to calculate scattered X-rays through some materials.
    Al-Ghorabie FH
    Australas Phys Eng Sci Med; 2003 Dec; 26(4):185-93. PubMed ID: 14995064
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events.
    Liaparinos PF; Kandarakis IS
    Med Phys; 2011 Jul; 38(7):4440-50. PubMed ID: 21859045
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data.
    Zourari K; Peppa V; Ballester F; Siebert FA; Papagiannis P
    Med Phys; 2014 Apr; 41(4):043901. PubMed ID: 24694161
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology.
    Boone JM; Seibert JA
    Med Phys; 1988; 15(5):713-20. PubMed ID: 3185407
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.