3. Use of a Mechanical Ventilator with Respiratory Function Monitoring Provides More Consistent Ventilation during Simulated Neonatal Resuscitation. Jain D; D'Ugard C; Aguilar A; Del Moral T; Bancalari E; Claure N Neonatology; 2020; 117(2):151-158. PubMed ID: 31593960 [TBL] [Abstract][Full Text] [Related]
4. Positive pressure ventilation coaching during neonatal bag-mask ventilation: A simulation-based pilot study. Sawyer T; Motz P; Schooley N; Umoren R J Neonatal Perinatal Med; 2019; 12(3):243-248. PubMed ID: 30909252 [TBL] [Abstract][Full Text] [Related]
5. Visual attention on a respiratory function monitor during simulated neonatal resuscitation: an eye-tracking study. Katz TA; Weinberg DD; Fishman CE; Nadkarni V; Tremoulet P; Te Pas AB; Sarcevic A; Foglia EE Arch Dis Child Fetal Neonatal Ed; 2019 May; 104(3):F259-F264. PubMed ID: 29903721 [TBL] [Abstract][Full Text] [Related]
6. A comparison of three neonatal resuscitation devices. Bennett S; Finer NN; Rich W; Vaucher Y Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202 [TBL] [Abstract][Full Text] [Related]
7. Visual attention patterns of team leaders during delivery room resuscitation. Weinberg DD; Newman H; Fishman CE; Katz TA; Nadkarni V; Herrick HM; Foglia EE Resuscitation; 2020 Feb; 147():21-25. PubMed ID: 31870924 [TBL] [Abstract][Full Text] [Related]
8. Neonatal resuscitation 3: manometer use in a model of face mask ventilation. O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F397-400. PubMed ID: 15871988 [TBL] [Abstract][Full Text] [Related]
9. T-piece or self inflating bag for positive pressure ventilation during delivery room resuscitation: an RCT. Thakur A; Saluja S; Modi M; Kler N; Garg P; Soni A; Kaur A; Chetri S Resuscitation; 2015 May; 90():21-4. PubMed ID: 25636895 [TBL] [Abstract][Full Text] [Related]
11. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation. Qureshi MJ; Kumar M Cochrane Database Syst Rev; 2018 Mar; 3(3):CD003314. PubMed ID: 29542112 [TBL] [Abstract][Full Text] [Related]
12. Sustained versus standard inflations during neonatal resuscitation to prevent mortality and improve respiratory outcomes. Bruschettini M; O'Donnell CP; Davis PG; Morley CJ; Moja L; Calevo MG Cochrane Database Syst Rev; 2020 Mar; 3(3):CD004953. PubMed ID: 32187656 [TBL] [Abstract][Full Text] [Related]
13. Randomised comparison of two neonatal resuscitation bags in manikin ventilation. Thallinger M; Ersdal HL; Ombay C; Eilevstjønn J; Størdal K Arch Dis Child Fetal Neonatal Ed; 2016 Jul; 101(4):F299-303. PubMed ID: 26437670 [TBL] [Abstract][Full Text] [Related]
14. Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model. Lucy MJ; Gamble JJ; Peeling A; Lam JTH; Balbuena L Paediatr Anaesth; 2018 Sep; 28(9):788-794. PubMed ID: 30175433 [TBL] [Abstract][Full Text] [Related]
15. Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks. O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F392-6. PubMed ID: 15871989 [TBL] [Abstract][Full Text] [Related]
16. T-piece versus self-inflating bag ventilation in preterm neonates at birth. Guinsburg R; de Almeida MFB; de Castro JS; Gonçalves-Ferri WA; Marques PF; Caldas JPS; Krebs VLJ; Souza Rugolo LMS; de Almeida JHCL; Luz JH; Procianoy RS; Duarte JLMB; Penido MG; Ferreira DMLM; Alves Filho N; Diniz EMA; Santos JP; Acquesta AL; Santos CND; Gonzalez MRC; da Silva RPVC; Meneses J; Lopes JMA; Martinez FE Arch Dis Child Fetal Neonatal Ed; 2018 Jan; 103(1):F49-F55. PubMed ID: 28663283 [TBL] [Abstract][Full Text] [Related]
17. Human or monitor feedback to improve mask ventilation during simulated neonatal cardiopulmonary resuscitation. Binder C; Schmölzer GM; O'Reilly M; Schwaberger B; Urlesberger B; Pichler G Arch Dis Child Fetal Neonatal Ed; 2014 Mar; 99(2):F120-3. PubMed ID: 24161928 [TBL] [Abstract][Full Text] [Related]
18. Assessment of Healthcare Provider Workload in Neonatal Resuscitation. Zehnder EC; Law BHY; Schmölzer GM Front Pediatr; 2020; 8():598475. PubMed ID: 33415089 [No Abstract] [Full Text] [Related]
19. [Newborn ventilation: comparison between a T-piece resuscitator and self-infating bags in a neonatal preterm simulator]. Szyld EG; Aguilar AM; Musante GA; Vain NE; Guerrero MN; Serra ME; Prudent LM; Carlo WA Arch Argent Pediatr; 2012 Apr; 110(2):106-12. PubMed ID: 22451282 [TBL] [Abstract][Full Text] [Related]
20. Sustained versus standard inflations during neonatal resuscitation to prevent mortality and improve respiratory outcomes. Bruschettini M; O'Donnell CP; Davis PG; Morley CJ; Moja L; Zappettini S; Calevo MG Cochrane Database Syst Rev; 2017 Jul; 7(7):CD004953. PubMed ID: 28707404 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]