These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 37375392)

  • 41. [The effect of fluoride on electrochemical corrosion of the dental pure titanium before and after adhesion of Streptococcus mutans].
    Geng L; Qiao GY; Gu KK
    Shanghai Kou Qiang Yi Xue; 2016 Apr; 25(2):150-6. PubMed ID: 27329875
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Monitoring of titanium base alloys-biofluids interface.
    Popa MV; Demetrescu I; Suh SH; Vasilescu E; Drob P; Ionita D; Vasilescu C
    Bioelectrochemistry; 2007 Nov; 71(2):126-34. PubMed ID: 17409027
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Effects of pH and elevated glucose levels on the electrochemical behavior of dental implants.
    Tamam E; Turkyilmaz I
    J Oral Implantol; 2014 Apr; 40(2):153-9. PubMed ID: 24779948
    [TBL] [Abstract][Full Text] [Related]  

  • 44. In vitro corrosion study of different TiO2 nanotube layers on titanium in solution with serum proteins.
    Yu WQ; Qiu J; Zhang FQ
    Colloids Surf B Biointerfaces; 2011 Jun; 84(2):400-5. PubMed ID: 21377339
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The Use of Electrochemical Methods to Determine the Effect of Nitrides of Alloying Elements on the Electrochemical Properties of Titanium β-Alloys.
    Jírů J; Hybášek V; Vlčák P; Fojt J
    Int J Mol Sci; 2023 Jan; 24(2):. PubMed ID: 36675171
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Discoloration of titanium alloy in acidic saline solutions with peroxide.
    Takemoto S; Hattori M; Yoshinari M; Kawada E; Oda Y
    Dent Mater J; 2013; 32(1):19-24. PubMed ID: 23370866
    [TBL] [Abstract][Full Text] [Related]  

  • 47. The effect of Staphylococcus aureus on the electrochemical behavior of porous Ti-6Al-4V alloy.
    Silva D; Guerra C; Muñoz H; Aguilar C; Walter M; Azocar M; Muñoz L; Gürbüz E; Ringuedé A; Cassir M; Sancy M
    Bioelectrochemistry; 2020 Dec; 136():107622. PubMed ID: 32784103
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Evaluation of Corrosion Behavior by Measuring Passivation Current Density of Dental Implant Coated with Bioceramic Materials.
    Hameed HA; Hasan HA; Alam MK
    Biomed Res Int; 2021; 2021():9934073. PubMed ID: 34222489
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Corrosion and tribocorrosion behavior of Ti-B4C composite intended for orthopaedic implants.
    Toptan F; Rego A; Alves AC; Guedes A
    J Mech Behav Biomed Mater; 2016 Aug; 61():152-163. PubMed ID: 26866451
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
    Grosgogeat B; Boinet M; Dalard F; Lissac M
    Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Electrochemical behavior of nano and femtosecond laser textured titanium alloy for implant surface modification.
    Jeong YH; Kim WG; Choe HC
    J Nanosci Nanotechnol; 2011 Feb; 11(2):1581-4. PubMed ID: 21456241
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Corrosion Behavior of Nitrided Layer of Ti6Al4V Titanium Alloy by Hollow Cathodic Plasma Source Nitriding.
    Zhang L; Shao M; Zhang Z; Yi X; Yan J; Zhou Z; Fang D; He Y; Li Y
    Materials (Basel); 2023 Apr; 16(8):. PubMed ID: 37109798
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A comparative evaluation between new ternary zirconium alloys as alternative metals for orthopedic and dental prosthetic devices.
    Shyti G; Rosalbino F; Macciò D; Scarabelli L; Quarto R; Giannoni P
    Int J Artif Organs; 2014 Feb; 37(2):149-64. PubMed ID: 24627169
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Corrosion behaviour of titanium in the presence of Streptococcus mutans.
    Souza JC; Ponthiaux P; Henriques M; Oliveira R; Teughels W; Celis JP; Rocha LA
    J Dent; 2013 Jun; 41(6):528-34. PubMed ID: 23578470
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Stress and electrochemical corrosion of titanium produced by laser rapid forming].
    Zhu JF; Gan K; Du TF; Gao B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Apr; 54(4):257-262. PubMed ID: 30955298
    [No Abstract]   [Full Text] [Related]  

  • 56. The intrinsically high pitting corrosion resistance of mechanically polished nitinol in simulated physiological solutions.
    Bai Z; Rotermund HH
    J Biomed Mater Res B Appl Biomater; 2011 Oct; 99(1):1-13. PubMed ID: 21648066
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effect of temperature on surface characteristics of nitrogen ion implanted biocompatible titanium.
    Aghajani H; Motlagh MS
    J Mater Sci Mater Med; 2017 Feb; 28(2):29. PubMed ID: 28108957
    [TBL] [Abstract][Full Text] [Related]  

  • 58. An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation.
    Royhman D; Radhakrishnan R; Yuan JC; Mathew MT; Mercuri LG; Sukotjo C
    J Craniomaxillofac Surg; 2014 Oct; 42(7):1052-61. PubMed ID: 24548869
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Corrosion resistance of Ti modified by chitosan-gold nanoparticles for orthopedic implantation.
    Farghali RA; Fekry AM; Ahmed RA; Elhakim HK
    Int J Biol Macromol; 2015 Aug; 79():787-99. PubMed ID: 25989146
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials.
    Aziz-Kerrzo M; Conroy KG; Fenelon AM; Farrell ST; Breslin CB
    Biomaterials; 2001 Jun; 22(12):1531-9. PubMed ID: 11374452
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.