  • 1. Response evaluation of two commercial thermoluminescence dosimeters (TLDs) against different parameters.
    Alanazi SF; Alarifi H; Alshehri A; Almurayshid M
    BJR Open; 2023; 5(1):20220035. PubMed ID: 37389000
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SU-E-T-92: on the Use of High-Sensitivity Thermoluminescent Dosimeters (TLDs) for Dosimetric Characterization of Low-Energy Brachytherapy Sources.
    Chen Z; Bongiorni P; Donahue W; Hearn R; Rodgers J; Nath R
    Med Phys; 2012 Jun; 39(6Part11):3723. PubMed ID: 28517162
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System.
    Hosseini Pooya S; Orouji T
    J Biomed Phys Eng; 2014 Jun; 4(2):43-8. PubMed ID: 25505769
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermoluminescent Characteristics of GR-200, TLD-700H and TLD-100 for Low Dose Measurement: Linearity, Repeatability, Dose Rate and Photon Energy Dependence.
    Alizadeh M; Mohseni M; Farhood B; Aliasgharzadeh A; Moradi H; Ramazani-Moghaddam-Arani A
    J Biomed Phys Eng; 2022 Apr; 12(2):111-116. PubMed ID: 35433523
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Instrumentation and dosimeter-size artifacts in quantitative thermoluminescence dosimetry of low-dose fields.
    Meigooni AS; Mishra V; Panth H; Williamson J
    Med Phys; 1995 May; 22(5):555-61. PubMed ID: 7643791
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.
    Bueno M; Carrasco P; Jornet N; Muñoz-Montplet C; Duch MA
    Med Phys; 2014 Aug; 41(8):081710. PubMed ID: 25086520
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characteristics of an OSLD in the diagnostic energy range.
    Al-Senan RM; Hatab MR
    Med Phys; 2011 Jul; 38(7):4396-405. PubMed ID: 21859040
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric Study of Heat-Treated Calcium-Aluminum-Silicon Borate Dosimeter for Diagnostic Radiology Applications.
    Algain I; Arib M; Al-Said SAF; Donya H
    Sensors (Basel); 2023 Jan; 23(2):. PubMed ID: 36679808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterisation of MCP-600D and MCP-700D thermoluminescence detectors and their applicability for photoneutron detection.
    Brunckhorst E; Sheng X; Todorovic M; Becker J; Cremers F
    Radiat Prot Dosimetry; 2008; 131(4):513-20. PubMed ID: 18922825
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of absorbed dose to water around a clinical HDR (192)Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response.
    Carlsson Tedgren A; Elia R; Hedtjarn H; Olsson S; Alm Carlsson G
    Med Phys; 2012 Feb; 39(2):1133-40. PubMed ID: 22320824
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields.
    Fartaria MJ; Reis C; Pereira J; Pereira MF; Cardoso JV; Santos LM; Oliveira C; Holovey V; Pascoal A; Alves JG
    Phys Med Biol; 2016 Sep; 61(17):6384-99. PubMed ID: 27499104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intercomparison of neutron personal dose equivalent measured by thermoluminescence dosimeters.
    Le NT; Hoang TP; Hui Z; Bui DK; Nguyen NQ; Hoang VK; Dinh TH; Nguyen MC; Cao VH; Tran HN
    Appl Radiat Isot; 2024 Mar; 205():111175. PubMed ID: 38194888
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SU-E-T-137: The Response of TLD-100 in Mixed Fields of Photons and Electrons.
    Lawless M; Junell S; Hammer C; DeWerd L
    Med Phys; 2012 Jun; 39(6Part11):3734. PubMed ID: 28517172
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo absorbed dose measurements with mini-TLDs--parameters affecting the reliability.
    Strandh M; Strand SE
    Acta Oncol; 1996; 35(6):713-9. PubMed ID: 8938219
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Type testing of a locally made LiF:Mg,Ti + PTFE TLD for its use as a personal dosimeter.
    Azorín J; Torijano E; Azorín C
    Appl Radiat Isot; 2018 Nov; 141():246-249. PubMed ID: 29843989
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of OSL and TL dosimetry systems against IEC and ICRP standards.
    Zidouh I; Arectout A; Bellahsaouia M; Elaarabi D; Chamlal H; Maroufi B; Sadeq Y; Tazi M; Rodenas J; Boukhal H; Chakir E
    Appl Radiat Isot; 2023 Jun; 196():110732. PubMed ID: 36924534
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SU-E-T-112: Experimental Characterization of a Novel Thermal Reservoir for Consistent and Accurate Annealing of High-Sensitivity TLDs.
    Donahue W; Bongiorni P; Hearn R; Rodgers J; Nath R; Chen Z
    Med Phys; 2012 Jun; 39(6Part11):3728-3729. PubMed ID: 28517151
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Response of TLD-100 in mixed fields of photons and electrons.
    Lawless MJ; Junell S; Hammer C; DeWerd LA
    Med Phys; 2013 Jan; 40(1):012103. PubMed ID: 23298105