These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 37393487)

  • 1. Comparison of four commercial dose calculation algorithms in different evaluation tests.
    Rostami A; Neto AJC; Paloor SP; Khalid AS; Hammoud R
    J Xray Sci Technol; 2023; 31(5):1013-1033. PubMed ID: 37393487
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media.
    Han T; Mikell JK; Salehpour M; Mourtada F
    Med Phys; 2011 May; 38(5):2651-64. PubMed ID: 21776802
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal metastases.
    Zhen H; Hrycushko B; Lee H; Timmerman R; Pompoš A; Stojadinovic S; Foster R; Jiang SB; Solberg T; Gu X
    J Appl Clin Med Phys; 2015 Jul; 16(4):181–192. PubMed ID: 26219014
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer.
    Han T; Followill D; Mikell J; Repchak R; Molineu A; Howell R; Salehpour M; Mourtada F
    Med Phys; 2013 May; 40(5):051710. PubMed ID: 23635258
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric comparison of analytical anisotropic algorithm and the two dose reporting modes of Acuros XB dose calculation algorithm in volumetric modulated arc therapy of carcinoma lung and carcinoma prostate.
    Gopalakrishnan Z; Bhasi S; P R; Menon SV; B S; Thayil AG; Nair RK
    Med Dosim; 2022 Autumn; 47(3):280-287. PubMed ID: 35690544
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions.
    Ojala JJ; Kapanen MK; Hyödynmaa SJ; Wigren TK; Pitkänen MA
    J Appl Clin Med Phys; 2014 Mar; 15(2):4662. PubMed ID: 24710454
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation.
    Zhao Y; Qi G; Yin G; Wang X; Wang P; Li J; Xiao M; Li J; Kang S; Liao X
    Radiat Oncol; 2014 Dec; 9():287. PubMed ID: 25511623
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams.
    Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D
    Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Benchmarking techniques for stereotactic body radiotherapy for early-stage glottic laryngeal cancer: LINAC-based non-coplanar VMAT vs. Cyberknife planning.
    Zhang Y; Chiu T; Dubas J; Tian Z; Lee P; Gu X; Yan Y; Sher D; Timmerman R; Zhao B
    Radiat Oncol; 2019 Nov; 14(1):193. PubMed ID: 31684993
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability.
    Padmanaban S; Warren S; Walsh A; Partridge M; Hawkins MA
    Radiat Oncol; 2014 Dec; 9():286. PubMed ID: 25533761
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation.
    Chow JC; Jiang R; Leung MK
    J Appl Clin Med Phys; 2010 Nov; 12(1):3424. PubMed ID: 21330989
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The accuracy of Acuros XB algorithm for radiation beams traversing a metallic hip implant - comparison with measurements and Monte Carlo calculations.
    Ojala J; Kapanen M; Sipilä P; Hyödynmaa S; Pitkänen M
    J Appl Clin Med Phys; 2014 Sep; 15(5):4912. PubMed ID: 25207577
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetric Validation of Treatment Planning System for Volumetric Modulated Arc Therapy Using AAPM Medical Physics Practice Guideline 5.b.
    Prasath S; Ramesh Babu P
    Asian Pac J Cancer Prev; 2024 May; 25(5):1715-1723. PubMed ID: 38809644
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of dosimetric accuracy of acuros XB and analytical anisotropic algorithm against Monte Carlo technique.
    Seniwal B; Bhatt CP; Fonseca TCF
    Biomed Phys Eng Express; 2020 Jan; 6(1):015035. PubMed ID: 33438623
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo calculations of radiotherapy dose in "homogeneous" anatomy.
    Kairn T; Livingstone AG; Crowe SB
    Phys Med; 2020 Oct; 78():156-165. PubMed ID: 33035927
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom.
    Han T; Mourtada F; Kisling K; Mikell J; Followill D; Howell R
    Med Phys; 2012 Apr; 39(4):2193-202. PubMed ID: 22482641
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A polar-coordinate-based pencil beam algorithm for VMAT dose computation with high-resolution gantry angle sampling.
    Tseng W; Yan G; Liu H; Kahler D; Li J; Liu C; Lu B
    Med Phys; 2022 Jun; 49(6):4026-4042. PubMed ID: 35355285
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric verification of lung phantom calculated by collapsed cone convolution: A Monte Carlo and experimental evaluation.
    Najafzadeh M; Nickfarjam A; Jabbari K; Markel D; Chow JCL; Takabi FS
    J Xray Sci Technol; 2019; 27(1):161-175. PubMed ID: 30614811
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma.
    Kan MW; Leung LH; So RW; Yu PK
    Med Phys; 2013 Mar; 40(3):031714. PubMed ID: 23464309
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric comparison and evaluation of two computational algorithms in VMAT treatment plans.
    Tsimpoukelli M; Patatoukas G; Chalkia M; Kollaros N; Kougioumtzopoulou A; Michaletou D; Kouloulias V; Platoni K
    J Appl Clin Med Phys; 2023 Sep; 24(9):e14051. PubMed ID: 37344987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.