BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 37393532)

  • 1. Manual aspiration of a pneumothorax after CT-guided lung biopsy: outcomes and risk factors.
    Chan MV; Afraz Z; Huo YR; Kandel S; Rogalla P
    Br J Radiol; 2023 Aug; 96(1148):20220366. PubMed ID: 37393532
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combined autologous blood patch-immediate patient rollover does not reduce the pneumothorax or chest drain rate following CT-guided lung biopsy compared to immediate patient rollover alone.
    Duignan JA; Ryan DT; O'Riordan B; O'Brien A; Healy GM; O'Brien C; Butler M; Keane MP; McCarthy C; Murphy DJ; Dodd JD
    Eur J Radiol; 2023 Mar; 160():110691. PubMed ID: 36640713
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: A prospective study.
    Ruud EA; Stavem K; Geitung JT; Borthne A; Søyseth V; Ashraf H
    Eur Radiol; 2021 Jun; 31(6):4243-4252. PubMed ID: 33354745
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CT-guided Lung Biopsy: Effect of Biopsy-side Down Position on Pneumothorax and Chest Tube Placement.
    Drumm O; Joyce EA; de Blacam C; Gleeson T; Kavanagh J; McCarthy E; McDermott R; Beddy P
    Radiology; 2019 Jul; 292(1):190-196. PubMed ID: 31084480
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pneumothorax after CT-guided transthoracic lung biopsy: A comparison between immediate and delayed occurrence.
    Bae K; Ha JY; Jeon KN
    PLoS One; 2020; 15(8):e0238107. PubMed ID: 32834016
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of autologous blood patch injection for pneumothorax rate after CT-guided percutaneous transthoracic lung biopsy: a systematic review and meta-analysis.
    Chen X; Bian Y; Li H; Li S; Shi Z; Zhao Y; Li H; Yang Y
    J Cardiothorac Surg; 2024 Jun; 19(1):332. PubMed ID: 38877547
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of manual aspiration immediately after complicated pneumothorax in CT-guided lung biopsy.
    Yamagami T; Kato T; Iida S; Hirota T; Yoshimatsu R; Nishimura T
    J Vasc Interv Radiol; 2005 Apr; 16(4):477-83. PubMed ID: 15802447
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Usual Interstitial Pneumonia: Associations With Complications After Percutaneous Transthoracic Needle Lung Biopsy.
    Park J; Lee JH; Hong W; Hwang EJ; Yoon SH; Goo JM; Park CM
    AJR Am J Roentgenol; 2024 Feb; 222(2):e2329938. PubMed ID: 37910039
    [No Abstract]   [Full Text] [Related]  

  • 10. Pneumothorax rates in CT-Guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors.
    Huo YR; Chan MV; Habib AR; Lui I; Ridley L
    Br J Radiol; 2020 Apr; 93(1108):20190866. PubMed ID: 31860329
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung.
    Nakamura M; Yoshizako T; Koyama S; Kitagaki H
    J Med Imaging Radiat Oncol; 2011 Oct; 55(5):474-8. PubMed ID: 22008165
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.
    Laurent F; Michel P; Latrabe V; Tunon de Lara M; Marthan R
    AJR Am J Roentgenol; 1999 Apr; 172(4):1049-53. PubMed ID: 10587145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pneumothoraxes after CT-guided percutaneous transthoracic needle aspiration biopsy of the lung: A single-center experience with 3426 patients.
    Polat G; Özdemir Ö; Serçe Unat D; Karadeniz G; Ayrancı A; Unat ÖS; Büyükşirin M; Maviş A; Yazgan S
    Tuberk Toraks; 2023 Mar; 71(1):67-74. PubMed ID: 36912411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pneumothorax after computed tomography-guided lung biopsy: Utility of immediate post-procedure computed tomography and one-hour delayed chest radiography.
    Weinand JT; du Pisanie L; Ngeve S; Commander C; Yu H
    PLoS One; 2023; 18(4):e0284145. PubMed ID: 37075048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies.
    Theilig D; Petschelt D; Mayerhofer A; Hamm B; Gebauer B; Geisel D
    Sci Rep; 2020 Jul; 10(1):10978. PubMed ID: 32620852
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tract sealing with normal saline after percutaneous transthoracic lung biopsies.
    Babu SB; Srinivasan S; Chung R; Chawla A; Tan HK; Lohan R
    J Med Imaging Radiat Oncol; 2020 Apr; 64(2):211-214. PubMed ID: 32037715
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Role of manual aspiration in treating pneumothorax after computed tomography-guided lung biopsy.
    Yamagami T; Terayama K; Yoshimatsu R; Matsumoto T; Miura H; Nishimura T
    Acta Radiol; 2009 Dec; 50(10):1126-33. PubMed ID: 19922309
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Risk factors for pneumothorax and pulmonary hemorrhage following computed tomography-guided transthoracic core-needle biopsy of subpleural lung lesions.
    Chiu JH; Chang YY; Weng CY; Lee YC; Yeh YC; Chen CK
    J Chin Med Assoc; 2022 Apr; 85(4):500-506. PubMed ID: 35383704
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy.
    Zeng LC; Du Y; Yang HF; Xie MG; Liao HQ; Zhang YD; Li L; Wang Q; Hu L; Xu XX
    Br J Radiol; 2015 Jul; 88(1051):20150227. PubMed ID: 25966292
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.