  • 1. [A rare pacemaker complication of a perforation by a ventricular screw electrode causing hemothorax].
    Gerckens U; Grube E; Kirchhoff PG; Lüderitz B
    Z Kardiol; 1986 May; 75(5):303-5. PubMed ID: 3739408
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Late perforation of a right ventricular pacing lead: a potentially dangerous complication.
    Schroeter T; Doll N; Borger MA; Groesdonk HV; Merk DR; Mohr FW
    Thorac Cardiovasc Surg; 2009 Apr; 57(3):176-7. PubMed ID: 19330760
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Left hemothorax: an unusual complication of delayed right ventricular perforation by a permanent pacemaker lead.
    Pojar M; Vobornik M; Novy J
    J Card Surg; 2013 May; 28(3):325-7. PubMed ID: 23480591
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left hemothorax: a presentation of a late ventricular perforation caused by an active fixation pacing lead.
    Bohora S; Unnikrishnan M; Ajit Kumar VK; Nayyar S; Tharakan J
    Int J Cardiol; 2010 Jun; 141(3):e43-6. PubMed ID: 19157597
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acute left hemothorax as a late complication of an active-fixation pacemaker lead.
    Forleo GB; Zeitani J; Perretta T; Della Rocca DG; Santini L; Simonetti G; Romeo F
    Ann Thorac Surg; 2013 Mar; 95(3):1081-4. PubMed ID: 23438538
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Late perforation of the right ventricle by displacement of pacemaker electrodes (report of 2 cases)].
    Ramírez Isunza JM; Argüelles Mier MA; Esparza González JJ
    Arch Inst Cardiol Mex; 1982; 52(2):129-33. PubMed ID: 7103601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Delayed isolated hemothorax caused by temporary pacemaker: a case report.
    Chen HY
    Int J Cardiol; 2007 Jan; 114(3):e109-10. PubMed ID: 17092582
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A rare case of late right ventricular perforation by a passive-fixation permanent pacemaker lead.
    Tziakas D; Alexoudis A; Konstantinou F; Chalikias G; Stakos D; Bougioukas G
    Europace; 2009 Jul; 11(7):968-9. PubMed ID: 19443432
    [TBL] [Abstract][Full Text] [Related]  

  • 9. ECHO and magnetic resonance imaging in a patient with high bleeding risk and ventricular perforation: a case report and literature review.
    Truscelli G; Galea N; Barillà F; Pellicori P; Toscano F; Gaudio C; Carbone I; Torromeo C
    Eur Rev Med Pharmacol Sci; 2011 Jun; 15(6):721-4. PubMed ID: 21796878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Uncomplicated heart and lung perforation by a displaced ventricular pacemaker lead: a case report.
    Selcuk H; Selcuk MT; Maden O; Ozeke O; Celenk MK; Turkvatan A; Korkmaz S
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):429-30. PubMed ID: 16650275
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Pericardial tamponade, an acute emergency during transvenous cardiac pacemaker implantation (author's transl)].
    Geiger G; Rückert U
    Thoraxchir Vask Chir; 1978 Dec; 26(6):402-6. PubMed ID: 751281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ventricular capture by anodal pacemaker stimulation.
    Occhetta E; Bortnik M; Marino P
    Europace; 2006 May; 8(5):385-7. PubMed ID: 16636000
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Late perforation of the heart, pericardium, and diaphragm by an active-fixation ventricular lead.
    Akyol A; Aydin A; Erdinler I; Oguz E
    Pacing Clin Electrophysiol; 2005 Apr; 28(4):350-1. PubMed ID: 15826277
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Accidental insertion of a temporary pacemaker electrode in the left ventricle: radiological and electrocardiographic diagnosis].
    Rickenbacher P; Stettler R; Osswald S
    Schweiz Med Wochenschr; 1996 Oct; 126(40):1688-92. PubMed ID: 8966502
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Electrocardiographic diagnosis of right ventricle perforation by a catheter-electrode in patients with permanent artificial pacemaker].
    Carvalho MA; Fonseca AA; Carneiro RD
    Arq Bras Cardiol; 1980 Nov; 35(5):413-7. PubMed ID: 7224903
    [No Abstract]   [Full Text] [Related]  

  • 16. [Perforation of a temporary transvenous pacemaker electrode in the left hemithorax. Diagnostic value of echocardiography].
    Erlemeier HH; Wolf W; Harland A; Schier H
    Z Kardiol; 1992 Apr; 81(4):226-9. PubMed ID: 1604926
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Right ventricular perforation by screw-in lead after permanent pacemaker implantation: a case report].
    Matsushita J; Nanba S; Tsuda K; Oke M
    J Cardiol; 2007 Nov; 50(5):325-8. PubMed ID: 18044462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inadvertent left ventricular pacing and perforation by a temporary pacemaker.
    Lin J; Wang L; Zhao Y
    J Electrocardiol; 2017; 50(5):686-689. PubMed ID: 28623015
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ventricular arrhythmia; sign of myocardial perforation by transvenous pacemaker electrode.
    Quan K; Amelkin SA; Wesolowski SA
    N Y State J Med; 1972 Aug; 72(15):1986-90. PubMed ID: 4506218
    [No Abstract]   [Full Text] [Related]  

  • 20. Single-step transvenous extraction of a passive fixation lead with delayed perforation of the right ventricle.
    Lopes LR; Brandão L; Carrageta M
    Europace; 2007 Aug; 9(8):672-3. PubMed ID: 17507363
    [TBL] [Abstract][Full Text] [Related]  