These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 37400231)

  • 1. Relationship between the aortic root and the atrioventricular conduction axis.
    Anderson RH; Spicer DE; Sánchez-Quintana D; Macias Y; Kapadia S; Tretter JT
    Heart; 2023 Nov; 109(24):1811-1818. PubMed ID: 37400231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Vulnerability of the ventricular conduction axis during transcatheter aortic valvar implantation: A translational pathologic study.
    Tretter JT; Spicer DE; Macías Y; Talbott C; Kasten JL; Sánchez-Quintana D; Kapadia SR; Anderson RH
    Clin Anat; 2023 Jul; 36(5):836-846. PubMed ID: 36864653
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The atrioventricular conduction axis and the aortic root-Inferences for transcatheter replacement of the aortic valve.
    Macías Y; Tretter JT; Sánchez-Quintana D; Cabrera JA; Spicer DE; de Almeida MC; Anderson RH
    Clin Anat; 2022 Mar; 35(2):143-154. PubMed ID: 34580916
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Transcatheter aortic valve implantation and conduction disturbances].
    Ait Said M; Coquard C; Horvilleur J; Manenti V; Fiorina L; Lacotte J; Salerno F
    Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):443-449. PubMed ID: 31668339
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis.
    Mogilansky C; Balan R; Deutsch C; Czesla M; Massoudy P
    Interact Cardiovasc Thorac Surg; 2019 Apr; 28(4):581-586. PubMed ID: 30412244
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Systematic Approach to High Implantation of SAPIEN-3 Valve Achieves a Lower Rate of Conduction Abnormalities Including Pacemaker Implantation.
    Sammour Y; Banerjee K; Kumar A; Lak H; Chawla S; Incognito C; Patel J; Kaur M; Abdelfattah O; Svensson LG; Tuzcu EM; Reed GW; Puri R; Yun J; Krishnaswamy A; Kapadia S
    Circ Cardiovasc Interv; 2021 Jan; 14(1):e009407. PubMed ID: 33430603
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation.
    López-Aguilera J; Segura Saint-Gerons JM; Mazuelos Bellido F; Suárez de Lezo J; Ojeda Pineda S; Pan Álvarez-Ossorio M; Romero Moreno MÁ; Pavlovic D; Espejo Pérez S; Suárez de Lezo J
    Rev Esp Cardiol (Engl Ed); 2016 Jan; 69(1):28-36. PubMed ID: 26215663
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computed tomography (CT) assessment of the membranous septal anatomy prior to transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 valve.
    Oestreich BA; Mbai M; Gurevich S; Nijjar PS; Adabag S; Bertog S; Kelly R; Garcia S
    Cardiovasc Revasc Med; 2018; 19(5 Pt B):626-631. PubMed ID: 29352699
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How to predict conduction disturbances after transcatheter aortic valve replacement.
    Novelli L; Jamie G; Regazzoli D; Reimers B; Frontera A; Mangieri A
    Kardiol Pol; 2023; 81(4):330-337. PubMed ID: 36745533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Conduction Disturbances and Pacing in Transcatheter Aortic Valve Replacement.
    Nakashima M; Jilaihawi H
    Interv Cardiol Clin; 2021 Oct; 10(4):455-463. PubMed ID: 34593109
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictors of permanent pacemaker implantation after transfemoral aortic valve implantation with the Lotus valve.
    Keßler M; Gonska B; Seeger J; Rottbauer W; Wöhrle J
    Am Heart J; 2017 Oct; 192():57-63. PubMed ID: 28938964
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Conduction Disturbances and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: Predictors and Prevention.
    Tsoi M; Tandon K; Zimetbaum PJ; Frishman WH
    Cardiol Rev; 2022 Jul-Aug 01; 30(4):179-187. PubMed ID: 34132653
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.
    Krackhardt F; Kherad B; Krisper M; Pieske B; Laule M; Tschöpe C
    Cardiol J; 2017; 24(3):250-258. PubMed ID: 28248410
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique.
    Iacovelli F; Giugliano G; Gerardi D; Salemme L; Cioppa A; Pucciarelli A; Popusoi G; Loizzi F; Schettino G; Favale S; Solimene F; Esposito G; Tesorio T; Stabile E
    Heart Vessels; 2022 Feb; 37(2):337-346. PubMed ID: 34524496
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Changes in atrioventricular conduction and predictors of pacemaker need after percutaneous implantation of the CoreValve®. Aortic valve prosthesis.
    Muñoz-García AJ; Hernández-García JM; Jiménez-Navarro MF; Alonso-Briales JH; Rodríguez-Bailón I; Peña-Hernández J; Fernández-Pastor J; Domínguez-Franco AJ; Barrera-Cordero A; Alzueta-Rodríguez J; de Teresa Galván E
    Rev Esp Cardiol; 2010 Dec; 63(12):1444-51. PubMed ID: 21144405
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evolution of high-grade atrioventricular conduction disorders after transcatheter aortic valve implantation in patients who underwent implantation of a pacemaker with specific mode-that minimizes ventricular pacing-activated.
    Irles D; Salerno F; Cassagneau R; Eschalier R; Maupain C; Dupuis JM; Mansourati J; Guedon L; Marijon E; Frey P;
    J Cardiovasc Electrophysiol; 2021 May; 32(5):1376-1384. PubMed ID: 33625762
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transcatheter aortic valve replacement and cardiac conduction.
    Shreenivas S; Schloss E; Choo J; Sarembock I; Lilly S; Kereiakes D
    Expert Rev Cardiovasc Ther; 2019 Apr; 17(4):293-304. PubMed ID: 30912984
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty.
    Campelo-Parada F; Nombela-Franco L; Urena M; Regueiro A; Jiménez-Quevedo P; Del Trigo M; Chamandi C; Rodríguez-Gabella T; Auffret V; Abdul-Jawad Altisent O; DeLarochellière R; Paradis JM; Dumont E; Philippon F; Pérez-Castellano N; Puri R; Macaya C; Rodés-Cabau J
    Rev Esp Cardiol (Engl Ed); 2018 Mar; 71(3):162-169. PubMed ID: 28566243
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.