These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 37400866)

  • 1. Can "In-Out-In" posterosuperior screws meet nutrient foramina in patients with femoral neck fractures?
    Wu S; Zhao S; Aisikaer A; Zhu X; Miao Y; Li G; Zhang Y; Mei J
    J Orthop Surg Res; 2023 Jul; 18(1):480. PubMed ID: 37400866
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Novel Fluoroscopic View for Improved Assessment of the Safety of the Posterosuperior Screw in Femoral Neck Fracture Fixation.
    Terhune EB; Polce EM; Williams JC
    J Bone Joint Surg Am; 2022 May; 104(10):889-895. PubMed ID: 35583544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The application of the 150° oblique tangential fluoroscopic view to detect the posterosuperior femoral neck screw in-out-in intraoperatively.
    Zhang J; Tang X
    Sci Rep; 2022 Jul; 12(1):12790. PubMed ID: 35896719
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Avoid the In-Out-In Posterosuperior Femoral Neck Screw: The Use of the Piriformis Fossa Radiographic Landmark.
    Adams JDJ; Walker JB; Loeffler M
    J Orthop Trauma; 2022 May; 36(5):224-227. PubMed ID: 34653103
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sequential fluoroscopic rollover images reliably identify "in-out-in" posterosuperior screws during percutaneous fixation of femoral neck fractures.
    Aibinder WR; Yuan BJ; Cross WW; Parry JA
    Eur J Orthop Surg Traumatol; 2020 Aug; 30(6):1061-1065. PubMed ID: 32306104
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High incidence of "in-out-in" posterosuperior screws after cannulated screw fixation of femoral neck fractures.
    Yuan BJ; Shamaa MT; Aibinder WR; Parry JA; Cross WW; Barlow JD; Sems SA
    Eur J Orthop Surg Traumatol; 2020 Dec; 30(8):1417-1420. PubMed ID: 32556582
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new posterosuperior screw placement strategy to avoid in-out-in screws in femoral neck fractures.
    Li SJ; Du SC; Hu SJ; Chang SM; Zhang YQ
    Front Surg; 2023; 10():1142135. PubMed ID: 37021090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Use of the Piriformis Fossa Radiographic Landmark to Predict "In-Out-In" Placement of the Posterosuperior Femoral Neck Screw.
    Kuttner NP; Hoggard TM; Cancio-Bello AM; Hidden KA; Yuan BJ; Adams JD
    J Orthop Trauma; 2023 Jul; 37(7):330-333. PubMed ID: 36750446
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The femoral neck safe zone: a radiographic simulation study to prevent cortical perforation with multiple screw insertion.
    Zhang YQ; Chang SM; Huang YG; Wang X
    J Orthop Trauma; 2015 May; 29(5):e178-82. PubMed ID: 25233164
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modified radiographic views to prevent the anterosuperior and posterosuperior bony violation during screw fixation of femoral neck fractures.
    Kumar A; Jameel J; Qureshi OA; Kumar M; Haider Y; Das S
    Eur J Orthop Surg Traumatol; 2021 Apr; 31(3):459-464. PubMed ID: 32939581
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiographic Quantification of Safe Zones for Screw Placement in the Femoral Neck: A Computed Tomography-Based Analysis.
    Kumar A; Kumar M; Arora R; Passey J; Das S; Chauhan S
    J Orthop Trauma; 2021 Mar; 35(3):136-142. PubMed ID: 33079842
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Finite element analysis of optimal selection of cannulated threaded screw for the prevention of femoral neck shortening after internal fixation for femoral neck fracture].
    Chen ZM; Yang F; Yu S; Shi ZW; Yu X; Chen XJ; Shi L; Wang CH; Pang QJ
    Zhongguo Gu Shang; 2022 Nov; 35(11):1042-8. PubMed ID: 36415189
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Number and distribution of nutrient foramina within the femoral neck and their relationship to the retinacula of Weitbrecht: an anatomical study.
    Mei J; Ni M; Wang G; Jia G; Liu S; Cui X; Jiang C; Wang H; Dai Y; Quan K; Chen R
    Anat Sci Int; 2017 Jan; 92(1):91-97. PubMed ID: 26690362
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimal position and apex-subchondral bone distance of cannulated screws for internal fixation of femoral neck fracture: A radiological study.
    Zhu Z; Liao F
    J Orthop Res; 2023 Jul; 41(7):1546-1554. PubMed ID: 36495052
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Posterior fully threaded positioning screw prevents femoral neck collapse in Garden I or II femoral neck fractures.
    Shin KH; Hong SH; Han SB
    Injury; 2020 Apr; 51(4):1031-1037. PubMed ID: 32089281
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Is the Cranial and Posterior Screw of the "Inverted Triangle" Configuration for Femoral Neck Fractures Safe?
    Hoffmann JC; Kellam J; Kumaravel M; Clark K; Routt MLC; Gary JL
    J Orthop Trauma; 2019 Jul; 33(7):331-334. PubMed ID: 30844954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ideal length of thread forms for screws used in screw fixation of nondisplaced femoral neck fractures.
    Liu C; Von Keudell A; McTague M; Rodriguez EK; Weaver MJ
    Injury; 2019 Mar; 50(3):727-732. PubMed ID: 30772052
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ideal screw positions for multiple screw fixation in femoral neck fractures - Study of proximal femur morphology in a Japanese population.
    Nakanishi Y; Hiranaka T; Shirahama M; Uesugi M; Okimura K; Tsubosaka M; Shibata Y; Hida Y; Fujishiro T; Uemoto H
    J Orthop Sci; 2018 May; 23(3):521-524. PubMed ID: 29459082
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Should cannulated screws be removed after a femoral neck fracture has healed, and how? A finite element analysis of the femur before and after cannulated screw removal.
    Wu L; Sun J; Fang N; Peng Q; Gao S; Liu L
    Int Orthop; 2022 Oct; 46(10):2393-2403. PubMed ID: 35852654
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Novel 3D-Printed Device for Precise Percutaneous Placement of Cannulated Compression Screws in Human Femoral Neck Fractures.
    Long C; Liu JH; Chai XP; Liu XF; Duan ZX
    Biomed Res Int; 2021; 2021():1308805. PubMed ID: 34222465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.