151 related articles for article (PubMed ID: 37410862)
1. Sagittal Alignment in Total Knee Arthroplasty: Are There Any Discrepancies Between Robotic-Assisted and Manual Axis Orientation?
An HM; Gu W; Nan SK; Liu Z; Li R; Chai W
J Bone Joint Surg Am; 2023 Sep; 105(17):1338-1343. PubMed ID: 37410862
[TBL] [Abstract][Full Text] [Related]
2. Joint line is restored in robotic-arm-assisted total knee arthroplasty performed with a tibia-based functional alignment.
Zambianchi F; Bazzan G; Marcovigi A; Pavesi M; Illuminati A; Ensini A; Catani F
Arch Orthop Trauma Surg; 2021 Dec; 141(12):2175-2184. PubMed ID: 34255176
[TBL] [Abstract][Full Text] [Related]
3. Posterior Tibial Slope in Computer-Navigated Total Knee Arthroplasty: The Transmalleolar Sagittal Axis Underestimates Slope Compared to Traditional Intramedullary Axis.
Chalmers BP; Quevedo-Gonzalez F; Gausden EB; Jerabek SA; Haas SB; Ast MP
J Arthroplasty; 2022 Jun; 37(6S):S207-S210. PubMed ID: 35240280
[TBL] [Abstract][Full Text] [Related]
4. How does the use of quantified gap-balancing affect component positioning and limb alignment in robotic total knee arthroplasty using functional alignment philosophy? A comparison of two robotic platforms.
Murphy GT; Shatrov J; Duong J; Fritsch BA
Int Orthop; 2023 May; 47(5):1221-1232. PubMed ID: 36740610
[TBL] [Abstract][Full Text] [Related]
5. CT Validation of Intraoperative Implant Position and Knee Alignment as Determined by the MAKO Total Knee Arthroplasty System.
Sires JD; Wilson CJ
J Knee Surg; 2021 Aug; 34(10):1133-1137. PubMed ID: 32131103
[TBL] [Abstract][Full Text] [Related]
6. Referencing the center of the femoral head during robotic or computer-navigated primary total knee arthroplasty results in less femoral component flexion than the traditional intramedullary axis.
Chalmers BP; Borsinger TM; Quevedo Gonzalez FJ; Vigdorchik JM; Haas SB; Ast MP
Knee; 2023 Oct; 44():172-179. PubMed ID: 37672908
[TBL] [Abstract][Full Text] [Related]
7. Extra-articular factors of the femur and tibia affecting knee balance in mechanically aligned total knee arthroplasty.
Ogawa H; Sengoku M; Shimokawa T; Nakamura Y; Ohnishi K; Matsumoto K; Akiyama H
Orthop Traumatol Surg Res; 2022 Dec; 108(8):103297. PubMed ID: 35508294
[TBL] [Abstract][Full Text] [Related]
8. Total Knee Arthroplasty in Patients With Extra-Articular Deformity: Restoration of Mechanical Alignment Using Accelerometer-Based Navigation System.
Matassi F; Cozzi Lepri A; Innocenti M; Zanna L; Civinini R; Innocenti M
J Arthroplasty; 2019 Apr; 34(4):676-681. PubMed ID: 30685259
[TBL] [Abstract][Full Text] [Related]
9. Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurements.
Kaneko T; Igarashi T; Takada K; Yoshizawa S; Ikegami H; Musha Y
Knee; 2021 Aug; 31():64-76. PubMed ID: 34118583
[TBL] [Abstract][Full Text] [Related]
10. Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes.
Nedopil AJ; Howell SM; Hull ML
Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3118-3127. PubMed ID: 31768572
[TBL] [Abstract][Full Text] [Related]
11. Discrepancies in Sagittal Alignment of the Lower Extremity Among Different Brands of Robotic Total Knee Arthroplasty Systems.
An HM; Wen JX; Gu W; Chen JY; Chai W; Li R
J Arthroplasty; 2024 Mar; ():. PubMed ID: 38508345
[TBL] [Abstract][Full Text] [Related]
12. Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice.
Peng Y; Ding R; Li M; Wang G; Zhong Z; Wei L; Huang C; Zhang N; Hernigou P; Wang W
Int Orthop; 2024 May; ():. PubMed ID: 38806820
[TBL] [Abstract][Full Text] [Related]
13. Surgical epicondylar axis is not orthogonal to the femoral mechanical knee axis in valgus knees with primary osteoarthritis: Three-dimensional analysis according to knee coronal alignment in 112 patients.
Sariali E; Moussellard HP
Knee; 2022 Dec; 39():91-99. PubMed ID: 36182830
[TBL] [Abstract][Full Text] [Related]
14. Comparison of CT with intra-operative navigation reported implant position utilising a robotic assisted technique in total knee arthroplasty.
Sharma N; Berera V; Petterwood J
Med Eng Phys; 2022 Oct; 108():103881. PubMed ID: 36195366
[TBL] [Abstract][Full Text] [Related]
15. Fibular axes are not a reliable landmark for tibial mechanical axes of osteoarthritic knees that underwent total knee arthroplasty.
Kuroda Y; Ishida K; Matsumoto T; Sasaki H; Matsuzaki T; Oka S; Takayama K; Tei K; Matsushita T; Tsumura N; Kuroda R; Kurosaka M
Knee Surg Sports Traumatol Arthrosc; 2015 Nov; 23(11):3362-7. PubMed ID: 25079132
[TBL] [Abstract][Full Text] [Related]
16. Increased Femoral Component Flexion and No Difference in Slope in Robotic- versus Computer-Assisted Total Knee Arthroplasty When Targeting Mechanical Alignment.
Klasan A; Anelli-Monti V; Neri T; Putnis SE; Zacherl M; Kammerlander C; Sadoghi P
J Knee Surg; 2024 Jan; 37(1):14-19. PubMed ID: 37734407
[TBL] [Abstract][Full Text] [Related]
17. Robotic-assisted total knee arthroplasty is more advantageous for knees with severe deformity: a randomized controlled trial study design.
Tian R; Duan X; Kong N; Li X; Wang J; Tian H; Shi Z; Yan S; Lyu J; Wang K; Yang P
Int J Surg; 2023 Mar; 109(3):287-296. PubMed ID: 36927832
[TBL] [Abstract][Full Text] [Related]
18. Mechanically aligned total knee arthroplasty carries a risk of bony gap changes and flexion-extension axis displacement.
Niki Y; Sassa T; Nagai K; Harato K; Kobayashi S; Yamashita T
Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3452-3458. PubMed ID: 28224199
[TBL] [Abstract][Full Text] [Related]
19. Multi-Planar Expansion of the Coronal Plane Alignment of the Knee Classification? A Computed Tomographic Study Indicates No Significant Correlation With Alignment Parameters in Other Planes.
Corbett J; Sinha P; Esposito CI; Wood JA; Chen DB; MacDessi SJ
J Arthroplasty; 2024 Feb; 39(2):336-342. PubMed ID: 37586596
[TBL] [Abstract][Full Text] [Related]
20. Restoring Tibial Slope and Sagittal Alignment of the Femoral Component in Unrestricted Kinematically Aligned Total Knee Arthroplasty Using Conventional versus Patient-Specific Instrumentation.
Sadoghi P; Draschl A; Leitner L; Fischerauer S; Koutp A; Clar C; Leithner A; Klasan A
J Knee Surg; 2024 Jan; 37(1):2-7. PubMed ID: 37734408
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]