120 related articles for article (PubMed ID: 37419047)
61. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.
Hell MM; Bittner D; Schuhbaeck A; Muschiol G; Brand M; Lell M; Uder M; Achenbach S; Marwan M
J Cardiovasc Comput Tomogr; 2014; 8(6):418-25. PubMed ID: 25439789
[TBL] [Abstract][Full Text] [Related]
62. Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems.
Samei E; Lo JY; Yoshizumi TT; Jesneck JL; Dobbins JT; Floyd CE; McAdams HP; Ravin CE
Radiology; 2005 Jun; 235(3):940-9. PubMed ID: 15845791
[TBL] [Abstract][Full Text] [Related]
63. Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT.
Solbak MS; Henning MK; England A; Martinsen AC; Aaløkken TM; Johansen S
Eur Radiol Exp; 2020 Sep; 4(1):57. PubMed ID: 32915405
[TBL] [Abstract][Full Text] [Related]
64. Lowered dose full-spine radiography in pediatric patients with idiopathic scoliosis.
Ernst C; Buls N; Laumen A; Van Gompel G; Verhelle F; de Mey J
Eur Spine J; 2018 May; 27(5):1089-1095. PubMed ID: 29589171
[TBL] [Abstract][Full Text] [Related]
65. Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.
Lai CJ; Shaw CC; Chen L; Altunbas MC; Liu X; Han T; Wang T; Yang WT; Whitman GJ; Tu SJ
Med Phys; 2007 Jul; 34(7):2995-3004. PubMed ID: 17822008
[TBL] [Abstract][Full Text] [Related]
66. Effect of varying X-ray tube voltage and additional filtration on image quality and patient dose in digital radiography system.
E A; A Y; T O
Appl Radiat Isot; 2023 Sep; 199():110893. PubMed ID: 37321050
[TBL] [Abstract][Full Text] [Related]
67. Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.
Daly MJ; Siewerdsen JH; Moseley DJ; Jaffray DA; Irish JC
Med Phys; 2006 Oct; 33(10):3767-80. PubMed ID: 17089842
[TBL] [Abstract][Full Text] [Related]
68. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.
Siegel MJ; Schmidt B; Bradley D; Suess C; Hildebolt C
Radiology; 2004 Nov; 233(2):515-22. PubMed ID: 15358847
[TBL] [Abstract][Full Text] [Related]
69. Quality of images acquired with and without grid in digital mammography.
Al Khalifah KH; Brindhaban A; Saeed RA
Radiol Phys Technol; 2014 Jan; 7(1):109-13. PubMed ID: 24190611
[TBL] [Abstract][Full Text] [Related]
70. The radiation exposure associated with cervical and lumbar spine radiographs.
Simpson AK; Whang PG; Jonisch A; Haims A; Grauer JN
J Spinal Disord Tech; 2008 Aug; 21(6):409-12. PubMed ID: 18679095
[TBL] [Abstract][Full Text] [Related]
71. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector.
Russo P; Mettivier G
Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943
[TBL] [Abstract][Full Text] [Related]
72. Comparing 10 kVp and 15% Rules in Extremity Radiography.
Coffey H; Chanopensiri V; Ly B; Nguyen D
Radiol Technol; 2020 Jul; 91(6):516-524. PubMed ID: 32606229
[TBL] [Abstract][Full Text] [Related]
73. Development of a radiographic technique for porcine head ballistic research.
Brooke N; Elliott J; Murphy T; Vera Stimpson L
Radiography (Lond); 2023 Oct; 29(6):980-983. PubMed ID: 37595528
[TBL] [Abstract][Full Text] [Related]
74. Dose-reducing strategies in combination offers substantial potential benefits to females requiring X-ray examination.
Grondin Y; Matthews K; McEntee M; Rainford L; Casey M; Tonra M; Al-Qattan E; McCrudden T; Foley M; Brennan PC
Radiat Prot Dosimetry; 2004; 108(2):123-32. PubMed ID: 14978292
[TBL] [Abstract][Full Text] [Related]
75. Investigation of dose reduction in neonatal radiography using specially designed phantoms and LiF:Mg,Cu,P TLDs.
Duggan L; Warren-Forward H; Smith T; Kron T
Br J Radiol; 2003 Apr; 76(904):232-7. PubMed ID: 12711642
[TBL] [Abstract][Full Text] [Related]
76. 90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism.
Leithner D; Gruber-Rouh T; Beeres M; Wichmann JL; Mahmoudi S; Martin SS; Lenga L; Albrecht MH; Booz C; Vogl TJ; Scholtz JE
Br J Radiol; 2018 Jul; 91(1088):20180269. PubMed ID: 29792729
[TBL] [Abstract][Full Text] [Related]
77. Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.
Kalva SP; Sahani DV; Hahn PF; Saini S
J Comput Assist Tomogr; 2006; 30(3):391-7. PubMed ID: 16778612
[TBL] [Abstract][Full Text] [Related]
78. Optimization of dual-energy subtraction chest radiography by use of a direct-conversion flat-panel detector system.
Fukao M; Kawamoto K; Matsuzawa H; Honda O; Iwaki T; Doi T
Radiol Phys Technol; 2015 Jan; 8(1):46-52. PubMed ID: 25119320
[TBL] [Abstract][Full Text] [Related]
79. Organ and effective doses in newborn patients during helical multislice computed tomography examination.
Staton RJ; Lee C; Lee C; Williams MD; Hintenlang DE; Arreola MM; Williams JL; Bolch WE
Phys Med Biol; 2006 Oct; 51(20):5151-66. PubMed ID: 17019030
[TBL] [Abstract][Full Text] [Related]
80. Optimisation of radiological protocols for chest imaging using computed radiography and flat-panel X-ray detectors.
Compagnone G; Casadio Baleni M; Di Nicola E; Valentino M; Benati M; Calzolaio LF; Oberhofer N; Fabbri E; Domenichelli S; Barozzi L
Radiol Med; 2013 Jun; 118(4):540-54. PubMed ID: 23090253
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]