These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 37420855)

  • 1. Optimal Pressure Sensor Deployment for Leak Identification in Water Distribution Networks.
    Yang G; Wang H
    Sensors (Basel); 2023 Jun; 23(12):. PubMed ID: 37420855
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Robust sensor placement for sustainable leakage management in water distribution networks of developing economies: A hybrid decision support framework.
    Zaman D; Gupta AK; Uddameri V; Tiwari MK; Sen D
    J Environ Manage; 2022 Oct; 320():115816. PubMed ID: 35932744
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Graph Laplace Regularization-based pressure sensor placement strategy for leak localization in the water distribution networks under joint hydraulic and topological feature spaces.
    Cheng M; Li J; Wang C; Ye C; Chang Z
    Water Res; 2024 Jun; 257():121666. PubMed ID: 38703543
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimal sensor placement for leak location in water distribution networks: A feature selection method combined with graph signal processing.
    Cheng M; Li J
    Water Res; 2023 Aug; 242():120313. PubMed ID: 37451191
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Leak detection and localization in water distribution networks using conditional deep convolutional generative adversarial networks.
    Rajabi MM; Komeilian P; Wan X; Farmani R
    Water Res; 2023 Jun; 238():120012. PubMed ID: 37150062
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Leak detection in real water distribution networks based on acoustic emission and machine learning.
    Fares A; Tijani IA; Rui Z; Zayed T
    Environ Technol; 2023 Nov; 44(25):3850-3866. PubMed ID: 35506881
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Robust Data-Driven Leak Localization in Water Distribution Networks Using Pressure Measurements and Topological Information.
    Alves D; Blesa J; Duviella E; Rajaoarisoa L
    Sensors (Basel); 2021 Nov; 21(22):. PubMed ID: 34833627
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Leak Detection in Water Pipes Using Submersible Optical Optic-Based Pressure Sensor.
    Wong L; Deo R; Rathnayaka S; Shannon B; Zhang C; Chiu WK; Kodikara J; Widyastuti H
    Sensors (Basel); 2018 Nov; 18(12):. PubMed ID: 30513585
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improving the leak detection efficiency in water distribution networks using noise loggers.
    Tijani IA; Abdelmageed S; Fares A; Fan KH; Hu ZY; Zayed T
    Sci Total Environ; 2022 May; 821():153530. PubMed ID: 35104524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficient k-means clustering and greedy selection-based reduction of nodal search space for optimization of sensor placement in the water distribution networks.
    Gautam DK; Kotecha P; Subbiah S
    Water Res; 2022 Jul; 220():118666. PubMed ID: 35709596
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gated graph neural networks for identifying contamination sources in water distribution systems.
    Li Z; Liu H; Zhang C; Fu G
    J Environ Manage; 2024 Feb; 351():119806. PubMed ID: 38118345
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selecting the best location of water quality sensors in water distribution networks by considering the importance of nodes and contaminations using NSGA-III (case study: Zahedan water distribution network, Iran).
    Harif S; Azizyan G; Dehghani Darmian M; Givehchi M
    Environ Sci Pollut Res Int; 2023 Apr; 30(18):53229-53252. PubMed ID: 36853532
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A convenient and stable graph-based pressure estimation methodology for water distribution networks: Development and field validation.
    Zhou X; Zhang J; Guo S; Liu S; Xin K
    Water Res; 2023 Apr; 233():119747. PubMed ID: 36841165
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An investigation of the possible scenarios for the optimal locating of quality sensors in the water distribution networks with uncertain contamination.
    Jafari H; Rajaee T; Nazif S
    J Water Health; 2020 Oct; 18(5):704-721. PubMed ID: 33095194
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of PVDF Wire Sensors for Leakage Localization in a Fluid-Filled Pipe.
    Sun P; Gao Y; Jin B; Brennan MJ
    Sensors (Basel); 2020 Jan; 20(3):. PubMed ID: 32012707
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optical Multimode Fiber-Based Pipe Leakage Sensor Using Speckle Pattern Analysis.
    Philosof J; Beiderman Y; Agdarov S; Beiderman Y; Zalevsky Z
    Sensors (Basel); 2023 Oct; 23(20):. PubMed ID: 37896727
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hydraulic performance benchmarking for effective management of water distribution networks: An innovative composite index-based approach.
    Zaman D; Gupta AK; Uddameri V; Tiwari MK; Ghosal PS
    J Environ Manage; 2021 Dec; 299():113603. PubMed ID: 34454199
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the acoustic filtering of the pipe and sensor in a buried plastic water pipe and its effect on leak detection: an experimental investigation.
    Almeida F; Brennan M; Joseph P; Whitfield S; Dray S; Paschoalini A
    Sensors (Basel); 2014 Mar; 14(3):5595-610. PubMed ID: 24658622
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Time-Series-Based Leakage Detection Using Multiple Pressure Sensors in Water Distribution Systems.
    Shao Y; Li X; Zhang T; Chu S; Liu X
    Sensors (Basel); 2019 Jul; 19(14):. PubMed ID: 31336795
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real time control of water distribution networks: A state-of-the-art review.
    Creaco E; Campisano A; Fontana N; Marini G; Page PR; Walski T
    Water Res; 2019 Sep; 161():517-530. PubMed ID: 31229732
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.