These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 37426920)

  • 21. Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating.
    Buijze GA; Blankevoort L; Tuijthof GJ; Sierevelt IN; Kloen P
    Arch Orthop Trauma Surg; 2010 Apr; 130(4):459-64. PubMed ID: 19823857
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Plate fixation of olecranon osteotomies.
    Hewins EA; Gofton WT; Dubberly J; MacDermid JC; Faber KJ; King GJ
    J Orthop Trauma; 2007 Jan; 21(1):58-62. PubMed ID: 17211271
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical and radiological results of three different techniques for fixation of the olecranon osteotomy in the surgical treatment of distal humerus fractures: A retrospective comparison of plate-screw, tension band and intramedullary nail.
    Yıldız V; Köse A; Aydın A; Dinçer R; Baydar M; Ayas MS
    Acta Orthop Traumatol Turc; 2021 Sep; 55(5):410-416. PubMed ID: 34730527
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical comparison of the new cross-locking intramedullary nail with tension band wiring for transverse olecranon fractures.
    Liang C; Li CY; Qin XS; Wang G; Duan K; Lu XB
    Injury; 2023 Apr; 54 Suppl 2():S95-S100. PubMed ID: 35871853
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation.
    Deschuyffeleer S; Duerinckx J; Caekebeke P
    J Wrist Surg; 2021 Apr; 10(2):154-157. PubMed ID: 33815952
    [No Abstract]   [Full Text] [Related]  

  • 26. A biomechanical comparison of multidirectional nail and locking plate fixation in unstable olecranon fractures.
    Argintar E; Martin BD; Singer A; Hsieh AH; Edwards S
    J Shoulder Elbow Surg; 2012 Oct; 21(10):1398-405. PubMed ID: 22154306
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Low-profile double plating of unstable osteoporotic olecranon fractures: a biomechanical comparative study.
    Wagner FC; Jaeger M; Friebis C; Maier D; Ophoven C; Yilmaz T; Südkamp NP; Reising K
    J Shoulder Elbow Surg; 2021 Jul; 30(7):1519-1526. PubMed ID: 33359398
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Cyclic loading of olecranon fracture fixation constructs.
    Hutchinson DT; Horwitz DS; Ha G; Thomas CW; Bachus KN
    J Bone Joint Surg Am; 2003 May; 85(5):831-7. PubMed ID: 12728033
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.
    Kim JS; Cho HK; Young KW; Kim JS; Lee KT
    Clin Orthop Surg; 2017 Dec; 9(4):514-520. PubMed ID: 29201305
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comminuted olecranon fractures: biomechanical testing of locked versus minifragment non-locked plate fixation.
    Wellman DS; Tucker SM; Baxter JR; Pardee NC; Lazaro LE; Smith CS; Lorich DG; Helfet DL
    Arch Orthop Trauma Surg; 2017 Sep; 137(9):1173-1179. PubMed ID: 28634743
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Fixation of olecranon osteotomy only with 6'5 mm partially trheaded cancellous screw is a safe an effective method used in surgical management of distal humerus fractures.
    Cañete San Pastor P; Lopez Valenciano J; Copete I; Prosper Ramos I
    J Exp Orthop; 2021 Jan; 8(1):4. PubMed ID: 33433762
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Predrilled locking compression plate is more accurate than tension band wiring in restoring articular geometry of the ulnar greater sigmoid notch after olecranon Chevron osteotomy.
    Goetti P; Behrends DA; Gallusser N; Terrier A; Becce F; Vauclair F
    Injury; 2020 Jul; 51(7):1597-1602. PubMed ID: 32430193
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of an Additional Nonlocking Screw in Olecranon Fracture Osteosynthesis Changes Failure Mechanism.
    Mehta S; Chin M; Sanville J; Namdari S; Hast MW
    Orthopedics; 2019 Jan; 42(1):e74-e80. PubMed ID: 30484851
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanical comparison of pin and nitinol bone staple fixation to pin and tension band wire fixation for the stabilization of canine olecranon osteotomies.
    Lai A; Christou C; Bailey C; Tan CJ; Culvenor J; Wang T; Walsh WR
    Vet Comp Orthop Traumatol; 2017 Sep; 30(5):324-330. PubMed ID: 28763518
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A new all-suture tension band tape fixation technique for simple olecranon fractures versus conventional tension band wire fixation: a comparative biomechanics study.
    Ernstbrunner L; Rupasinghe HS; Almond M; Jo OI; Zbeda RM; Oppy A; Treseder T; Pullen C; Ek ET; Ackland DC
    J Shoulder Elbow Surg; 2022 Jul; 31(7):1376-1384. PubMed ID: 35167913
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Olecranon Osteotomy Fixation Following Distal Humerus Open Reduction and Internal Fixation: Clinical Results of Plate and Screws Versus Tension Band Wiring.
    Haglin JM; Lott A; Kugelman DN; Bird M; Konda SR; Tejwani NC; Egol KA
    Orthopedics; 2021 Jan; 44(1):e107-e113. PubMed ID: 33089334
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comminuted olecranon fracture fixation with pre-contoured plate: Comparison of composite and cadaver bones.
    Hamilton DA; Reilly D; Wipf F; Kamineni S
    World J Orthop; 2015 Oct; 6(9):705-11. PubMed ID: 26495247
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A pilot biomechanical study comparing a novel, intramedullary Nail/Plate construct to standard Dual-Plate fixation of intra-articular C2.3 distal humerus fractures.
    Shah NV; Hayes WT; Wang H; Hordines JC; Karakostas JE; Paxinos O; Koehler SM
    Injury; 2020 Oct; 51(10):2148-2157. PubMed ID: 32605784
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures.
    Zalavras CG; Vercillo MT; Jun BJ; Otarodifard K; Itamura JM; Lee TQ
    J Shoulder Elbow Surg; 2011 Jan; 20(1):12-20. PubMed ID: 21134662
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study.
    Thamyongkit S; Abbasi P; Parks BG; Shafiq B; Hasenboehler EA
    BMC Musculoskelet Disord; 2022 Jan; 23(1):86. PubMed ID: 35078451
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.