These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 37427309)

  • 1. Energy Calibration of Nonlinear Microcalorimeters with Uncertainty Estimates from Gaussian Process Regression.
    Fowler JW; Alpert BK; O'Neil GC; Swetz DS; Ullom JN
    J Low Temp Phys; 2022; 209(5-6):. PubMed ID: 37427309
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Energy calibration of high-resolution X-Ray TES microcalorimeters with 3 eV optical photons.
    Jaeckel FT; Ambarish CV; Christensen N; Gruenke R; Hu L; McCammon D; McPheron M; Meyer M; Nelms KL; Roy A; Wulf D; Zhang S; Zhou Y; Adams JS; Bandler SR; Chervenak JA; Datesman AM; Eckart ME; Ewin AJ; Finkbeiner FM; Kelley R; Kilbourne CA; Miniussi AR; Porter FS; Sadleir JE; Sakai K; Smith SJ; Wakeham N; Wassell E; Yoon W; Morgan KM; Schmidt DR; Swetz DS; Ullom JN
    IEEE Trans Appl Supercond; 2019 Aug; 29(5):. PubMed ID: 31186605
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration and Testing of Small High-Resolution Transition Edge Sensor Microcalorimeters with Optical Photons.
    Jaeckel FT; Ambarish CV; Dai H; Liu S; McCammon D; McPheron M; Nelms KL; Roy A; Stueber HR; Bandler SR; Chervenak JA; Sakai K; Smith SJ
    IEEE Trans Appl Supercond; 2021 Jan; 1():1. PubMed ID: 33531792
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals.
    Fowler JW; O'Neil GC; Alpert BK; Bennett DA; Denison EV; Doriese WB; Hilton GC; Hudson LT; Joe YI; Morgan KM; Schmidt DR; Swetz DS; Szabo CI; Ullom JN
    Metrologia; 2021 Feb; 58(1):. PubMed ID: 34354301
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Uncertainty in HPGe detector calibrations for in situ gamma-ray spectrometry.
    Boson J; Johansson L; Ramebäck H; Agren G
    Radiat Prot Dosimetry; 2009 Jun; 134(2):122-9. PubMed ID: 19429646
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Techniques for precise energy calibration of particle pixel detectors.
    Kroupa M; Campbell-Ricketts T; Bahadori A; Empl A
    Rev Sci Instrum; 2017 Mar; 88(3):033301. PubMed ID: 28372389
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A high resolution gamma-ray spectrometer based on superconducting microcalorimeters.
    Bennett DA; Horansky RD; Schmidt DR; Hoover AS; Winkler R; Alpert BK; Beall JA; Doriese WB; Fowler JW; Fitzgerald CP; Hilton GC; Irwin KD; Kotsubo V; Mates JA; O'Neil GC; Rabin MW; Reintsema CD; Schima FJ; Swetz DS; Vale LR; Ullom JN
    Rev Sci Instrum; 2012 Sep; 83(9):093113. PubMed ID: 23020368
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image-based spectral distortion correction for photon-counting x-ray detectors.
    Ding H; Molloi S
    Med Phys; 2012 Apr; 39(4):1864-76. PubMed ID: 22482608
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
    Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Soft x-ray performance of high-resolution superconducting spectrometers.
    Mears CA; Frank M; Labov SE; Hiller LJ; le Grand JB; Chow D; Lindeman MA; Netel H; Barfknecht AT
    J Xray Sci Technol; 1997 Jan; 7(3):225-32. PubMed ID: 21311119
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of energy response for photon-counting detectors using x-ray fluorescence.
    Ding H; Cho HM; Barber WC; Iwanczyk JS; Molloi S
    Med Phys; 2014 Dec; 41(12):121902. PubMed ID: 25471962
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.
    Cho HM; Ding H; Ziemer BP; Molloi S
    Phys Med Biol; 2014 Dec; 59(23):7211-27. PubMed ID: 25369288
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of intrinsic energy dependence of point-like inorganic scintillation detector in brachytherapy.
    Georgi P; Tedgren ÅC; Persson L; Johansen JG
    Med Phys; 2024 Jul; 51(7):5059-5069. PubMed ID: 38197459
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dual-Threshold Time-over-Threshold Nonlinearity Correction for PET Detectors.
    Gaudin É; Thibaudeau C; Arpin L; Bouziri H; Fontaine R; Lecomte R
    Nucl Instrum Methods Phys Res A; 2020 Aug; 971():. PubMed ID: 32624634
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calibration of image plate and back illuminated charge coupled device detectors at the thermal emission band of high Z target laser produced plasmas (80-800 eV).
    Ehrlich Y; Levy I; Fraenkel M
    Rev Sci Instrum; 2022 Aug; 93(8):083510. PubMed ID: 36050101
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry.
    Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J
    Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multi-energy x-ray detector calibration for T and impurity density (n) measurements of MCF plasmas.
    Maddox J; Pablant N; Efthimion P; Delgado-Aparicio L; Hill KW; Bitter M; Reinke ML; Rissi M; Donath T; Luethi B; Stratton B
    Rev Sci Instrum; 2016 Nov; 87(11):11E320. PubMed ID: 27910559
    [TBL] [Abstract][Full Text] [Related]  

  • 19. K-edge energy-based calibration method for photon counting detectors.
    Ge Y; Ji X; Zhang R; Li K; Chen GH
    Phys Med Biol; 2017 Dec; 63(1):015022. PubMed ID: 29072192
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Energy calibration of the pixels of spectral X-ray detectors.
    Panta RK; Walsh MF; Bell ST; Anderson NG; Butler AP; Butler PH
    IEEE Trans Med Imaging; 2015 Mar; 34(3):697-706. PubMed ID: 25051546
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.