BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 37430394)

  • 1. A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study.
    Sakai A; Masuda A; Eguchi T; Furumatsu K; Iemoto T; Yoshida S; Okabe Y; Yamanaka K; Miki I; Kakuyama S; Yagi Y; Shirasaka D; Kohashi S; Kobayashi T; Shiomi H; Kodama Y
    Clin Endosc; 2024 May; 57(3):375-383. PubMed ID: 37430394
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.
    Mukai T; Yasuda I; Isayama H; Iwashita T; Itoi T; Kawakami H; Kogure H; Nakai Y
    Dig Endosc; 2016 Sep; 28(6):671-9. PubMed ID: 26927207
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Antireflux covered metal stent for nonresectable distal malignant biliary obstruction: Multicenter randomized controlled trial.
    Hamada T; Isayama H; Nakai Y; Iwashita T; Ito Y; Mukai T; Yagioka H; Saito T; Togawa O; Ryozawa S; Hirano K; Mizuno S; Yamamoto N; Kogure H; Yasuda I; Koike K
    Dig Endosc; 2019 Sep; 31(5):566-574. PubMed ID: 30803046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Partially covered metal stents have longer patency than uncovered and fully covered metal stents in the management of distal malignant biliary obstruction: a retrospective study.
    Yokota Y; Fukasawa M; Takano S; Kadokura M; Shindo H; Takahashi E; Hirose S; Kawakami S; Fukasawa Y; Sato T; Enomoto N
    BMC Gastroenterol; 2017 Oct; 17(1):105. PubMed ID: 29020933
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Feasibility of Whole-Liver Drainage with a Novel 8 mm Fully Covered Self-Expandable Metal Stent Possessing an Ultra-Slim Introducer for Malignant Hilar Biliary Obstructions.
    Matsubara S; Nakagawa K; Suda K; Otsuka T; Oka M; Nagoshi S
    J Clin Med; 2022 Oct; 11(20):. PubMed ID: 36294431
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intraductal placement of a fully covered metal stent with a long string for distal malignant biliary obstruction without endoscopic sphincterotomy: Prospective multi-center feasibility study.
    Inoue T; Suzuki Y; Okumura F; Naitoh I; Sano H; Ibusuki M; Kitano R; Kobayashi Y; Ito K; Yoneda M
    Dig Endosc; 2020 Sep; 32(6):949-956. PubMed ID: 31898346
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of multi-hole self-expandable metal stent compared to fully covered and uncovered self-expandable metal stents in patients with unresectable malignant distal biliary obstruction: a propensity analysis.
    Kulpatcharapong S; Piyachaturawat P; Mekaroonkamol P; Angsuwatcharakon P; Ridtitid W; Kongkam P; Rerknimitr R
    Surg Endosc; 2024 Jan; 38(1):212-221. PubMed ID: 37964091
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes of Intraductal Placement of Covered Metal Stents for Unresectable Distal Malignant Biliary Obstruction.
    Yamada M; Takeda T; Sasaki T; Okamoto T; Hamada T; Ishitsuka T; Nakagawa H; Mie T; Furukawa T; Kasuga A; Matsuyama M; Ozaka M; Kobara H; Masaki T; Sasahira N
    J Clin Med; 2023 Mar; 12(5):. PubMed ID: 36902787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Utility and Safety of a Novel Fully Covered Metal Stent in Unresectable Distal Malignant Biliary Obstruction.
    Yamao K; Takenaka M; Ogura T; Hashimoto H; Matsumoto H; Yamamoto M; Ikeura T; Kurita A; Li ZL; Shiomi H; Chiba Y; Kudo M; Sanuki T
    Dig Dis Sci; 2020 Dec; 65(12):3702-3709. PubMed ID: 32036515
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial.
    Kitano M; Yamashita Y; Tanaka K; Konishi H; Yazumi S; Nakai Y; Nishiyama O; Uehara H; Mitoro A; Sanuki T; Takaoka M; Koshitani T; Arisaka Y; Shiba M; Hoki N; Sato H; Sasaki Y; Sato M; Hasegawa K; Kawabata H; Okabe Y; Mukai H
    Am J Gastroenterol; 2013 Nov; 108(11):1713-22. PubMed ID: 24042190
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Covered versus uncovered metal stent for endoscopic drainage of a malignant distal biliary obstruction: Meta-analysis.
    Yamashita Y; Tachikawa A; Shimokawa T; Yamazaki H; Itonaga M; Sakai Y; Sugiyama H; Nakai Y; Tanaka K; Isayama H; Kitano M
    Dig Endosc; 2022 Jul; 34(5):938-951. PubMed ID: 35114036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of 8- and 10-mm diameter fully covered self-expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction.
    Kawashima H; Hashimoto S; Ohno E; Ishikawa T; Morishima T; Matsubara H; Sugimoto H; Nonogaki K; Kanamori A; Hara K; Kuwahara T; Nakamura M; Miyahara R; Ishigami M; Ando M; Hirooka Y;
    Dig Endosc; 2019 Jul; 31(4):439-447. PubMed ID: 30714216
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a 12-mm diameter covered self-expandable end bare metal stent for malignant biliary obstruction.
    Nakaoka K; Hashimoto S; Kawabe N; Nakano T; Kan T; Ohki M; Ochi Y; Takamura T; Kurashita T; Nomura S; Koyama K; Fukui A; Yoshioka K
    Endosc Int Open; 2018 Oct; 6(10):E1164-E1170. PubMed ID: 30302372
    [No Abstract]   [Full Text] [Related]  

  • 14. Side-by-side partially covered self-expandable metal stent placement for malignant hilar biliary obstruction.
    Kitamura K; Yamamiya A; Ishii Y; Mitsui Y; Nomoto T; Yoshida H
    Endosc Int Open; 2017 Dec; 5(12):E1211-E1217. PubMed ID: 29202005
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of outcomes between secondary fully covered and uncovered self-expandable metal stents in the treatment of recurrent biliary obstruction of pancreatic cancer.
    Kataoka K; Kawashima H; Ohno E; Ishikawa T; Mizutani Y; Iida T; Furukawa K; Nakamura M; Honda T; Ishigami M; Fujishiro M
    Surg Endosc; 2022 Aug; 36(8):5676-5683. PubMed ID: 35020055
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adverse events of self-expandable metal stent placement for malignant distal biliary obstruction: a large multicenter study.
    Tamura T; Yamai T; Uza N; Yamasaki T; Masuda A; Tomooka F; Maruyama H; Shigekawa M; Ogura T; Kuriyama K; Asada M; Matsumoto H; Takenaka M; Mandai K; Osaki Y; Matsumoto K; Sanuki T; Shiomi H; Yamagata Y; Doi T; Inatomi O; Nakanishi F; Emori T; Shimatani M; Asai S; Fujigaki S; Shimokawa T; Kitano M
    Gastrointest Endosc; 2024 Jan; 99(1):61-72.e8. PubMed ID: 37598864
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retrospective evaluation of slim fully covered self-expandable metallic stent for unresectable malignant hilar biliary obstruction.
    Takahashi S; Fujisawa T; Ushio M; Fukuma T; Suzuki A; Takasaki Y; Ito K; Tomishima K; Ishii S; Isayama H
    J Hepatobiliary Pancreat Sci; 2023 Mar; 30(3):408-415. PubMed ID: 35918901
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Utility of laser-cut covered self-expandable metal stents for unresectable malignant distal biliary obstruction: a single-center experience.
    Marui S; Uza N; Yamazaki H; Ota S; Nakamura T; Yoshida H; Okada H; Hirano T; Kuwada T; Sogabe Y; Tomono T; Matsumori T; Morita T; Nishikawa Y; Tsuda M; Maruno T; Shiokawa M; Kodama Y; Seno H
    Endoscopy; 2020 Aug; 52(8):664-668. PubMed ID: 32316040
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluating optimal bilateral biliary stenting in endoscopic reintervention after initial plastic stent dysfunction for unresectable malignant hilar biliary obstruction: Retrospective cross-sectional study.
    Okuno M; Iwata K; Iwashita T; Mukai T; Shimojo K; Ohashi Y; Iwasa Y; Senju A; Iwata S; Tezuka R; Ichikawa H; Mita N; Uemura S; Yoshida K; Maruta A; Tomita E; Yasuda I; Shimizu M
    Dig Endosc; 2024 Mar; ():. PubMed ID: 38486465
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of bilateral intraductal plastic stent for malignant hilar biliary obstruction compared with bilateral self-expandable metal stent: a propensity score-matched cohort analysis.
    Okuno M; Iwata K; Iwashita T; Mukai T; Shimojo K; Ohashi Y; Iwasa Y; Senju A; Iwata S; Tezuka R; Ichikawa H; Mita N; Uemura S; Yoshida K; Maruta A; Tomita E; Yasuda I; Shimizu M
    Gastrointest Endosc; 2023 Nov; 98(5):776-786. PubMed ID: 37392955
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.