These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 37439236)

  • 21. Mapping Regional Differences of Local Pressure-Volume Curves With Electrical Impedance Tomography.
    Beda A; Carvalho AR; Carvalho NC; Hammermüller S; Amato MB; Muders T; Gittel C; Noreikat K; Wrigge H; Reske AW
    Crit Care Med; 2017 Apr; 45(4):679-686. PubMed ID: 28079607
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury.
    Kunst PW; Vazquez de Anda G; Böhm SH; Faes TJ; Lachmann B; Postmus PE; de Vries PM
    Crit Care Med; 2000 Dec; 28(12):3891-5. PubMed ID: 11153631
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A model-based source separation algorithm for lung perfusion imaging using electrical impedance tomography.
    Hentze B; Muders T; Hoog Antink C; Putensen C; Larsson A; Hedenstierna G; Walter M; Leonhardt S
    Physiol Meas; 2021 Aug; 42(8):. PubMed ID: 34167091
    [No Abstract]   [Full Text] [Related]  

  • 24. Effects of airway pressure release ventilation on lung physiology assessed by electrical impedance tomography in patients with early moderate-to-severe ARDS.
    Li R; Wu Y; Zhang H; Wang A; Zhao X; Yuan S; Yang L; Zou X; Shang Y; Zhao Z
    Crit Care; 2023 May; 27(1):178. PubMed ID: 37158961
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Prone positioning improves ventilation-perfusion matching assessed by electrical impedance tomography in patients with ARDS: a prospective physiological study.
    Wang YX; Zhong M; Dong MH; Song JQ; Zheng YJ; Wu W; Tao JL; Zhu L; Zheng X
    Crit Care; 2022 May; 26(1):154. PubMed ID: 35624489
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Relationship between lung ultrasound and electrical impedance tomography as regional assessment tools during PEEP titration in acute respiratory distress syndrome caused by multi-lobar pneumonia: a pilot study.
    Theerawit P; Pukapong P; Sutherasan Y
    J Clin Monit Comput; 2023 Jun; 37(3):889-897. PubMed ID: 36592267
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [The mechanical ventilation guided by electrical impedance tomography in acute respiratory distress syndrome].
    Sun Q; Liu L; Yang Y
    Zhonghua Yi Xue Za Zhi; 2024 Apr; 104(15):1247-1252. PubMed ID: 38637164
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study.
    Muders T; Hentze B; Leonhardt S; Putensen C
    J Clin Med; 2023 Apr; 12(8):. PubMed ID: 37109088
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging.
    Frerichs I; Hinz J; Herrmann P; Weisser G; Hahn G; Quintel M; Hellige G
    IEEE Trans Med Imaging; 2002 Jun; 21(6):646-52. PubMed ID: 12166861
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electrical Impedance Tomography for Cardio-Pulmonary Monitoring.
    Putensen C; Hentze B; Muenster S; Muders T
    J Clin Med; 2019 Aug; 8(8):. PubMed ID: 31394721
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver.
    van Genderingen HR; van Vught AJ; Jansen JR
    Intensive Care Med; 2003 Feb; 29(2):233-40. PubMed ID: 12594585
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Derecruitment volume assessment derived from pressure-impedance curves with electrical impedance tomography in experimental acute lung injury.
    Sun XM; Chen GQ; Wang YM; Zhou YM; Chen JR; Cheng KM; Yang YL; Zhang LL; Li HL; Zhou JX
    J Int Med Res; 2020 Aug; 48(8):300060520949037. PubMed ID: 32816562
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effects of Prone Position on Lung Recruitment and Ventilation-Perfusion Matching in Patients With COVID-19 Acute Respiratory Distress Syndrome: A Combined CT Scan/Electrical Impedance Tomography Study.
    Fossali T; Pavlovsky B; Ottolina D; Colombo R; Basile MC; Castelli A; Rech R; Borghi B; Ianniello A; Flor N; Spinelli E; Catena E; Mauri T
    Crit Care Med; 2022 May; 50(5):723-732. PubMed ID: 35200194
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study.
    Richard JC; Pouzot C; Gros A; Tourevieille C; Lebars D; Lavenne F; Frerichs I; Guérin C
    Crit Care; 2009; 13(3):R82. PubMed ID: 19480694
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrical impedance tomography: so close to touching the holy grail.
    Constantin JM; Perbet S; Delmas J; Futier E
    Crit Care; 2014 Jul; 18(4):164. PubMed ID: 25041593
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.
    Spadaro S; Mauri T; Böhm SH; Scaramuzzo G; Turrini C; Waldmann AD; Ragazzi R; Pesenti A; Volta CA
    Crit Care; 2018 Jan; 22(1):26. PubMed ID: 29386048
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Absolute values of regional ventilation-perfusion mismatch in patients with ARDS monitored by electrical impedance tomography and the role of dead space and shunt compensation.
    Leali M; Marongiu I; Spinelli E; Chiavieri V; Perez J; Panigada M; Grasselli G; Mauri T
    Crit Care; 2024 Jul; 28(1):241. PubMed ID: 39010228
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dorsal recruitment with flow-controlled expiration (FLEX): an experimental study in mechanically ventilated lung-healthy and lung-injured pigs.
    Borgmann S; Schmidt J; Goebel U; Haberstroh J; Guttmann J; Schumann S
    Crit Care; 2018 Sep; 22(1):245. PubMed ID: 30268138
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Lung Perfusion Assessment by Bedside Electrical Impedance Tomography in Critically Ill Patients.
    Xu M; He H; Long Y
    Front Physiol; 2021; 12():748724. PubMed ID: 34721072
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Electrical Impedance Tomography to Monitor Hypoxemic Respiratory Failure.
    Franchineau G; Jonkman AH; Piquilloud L; Yoshida T; Costa E; Rozé H; Camporota L; Piraino T; Spinelli E; Combes A; Alcala GC; Amato M; Mauri T; Frerichs I; Brochard LJ; Schmidt M
    Am J Respir Crit Care Med; 2024 Mar; 209(6):670-682. PubMed ID: 38127779
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.