These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 37439965)

  • 1. Phantom and clinical evaluation of Block Sequential Regularized Expectation Maximization (BSREM) reconstruction algorithm in 68Ga-PSMA PET-CT studies.
    Sadeghi F; Sheikhzadeh P; Kasraie N; Farzanehfar S; Abbasi M; Salehi Y; Ay M
    Phys Eng Sci Med; 2023 Sep; 46(3):1297-1308. PubMed ID: 37439965
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Regularized reconstruction of digital time-of-flight
    Lindström E; Velikyan I; Regula N; Alhuseinalkhudhur A; Sundin A; Sörensen J; Lubberink M
    Theranostics; 2019; 9(12):3476-3484. PubMed ID: 31281491
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative and Qualitative Improvement of Low-Count [
    Seo Y; Khalighi MM; Wangerin KA; Deller TW; Wang YH; Jivan S; Kohi MP; Aggarwal R; Flavell RR; Behr SC; Evans MJ
    Mol Imaging Biol; 2020 Feb; 22(1):208-216. PubMed ID: 30993558
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of block-sequential regularized expectation maximization reconstruction of
    Lindström E; Lindsjö L; Sundin A; Sörensen J; Lubberink M
    EJNMMI Phys; 2020 Jun; 7(1):40. PubMed ID: 32542512
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of Penalized-Likelihood Estimation Reconstruction on a Digital Time-of-Flight PET/CT Scanner for
    Lindström E; Sundin A; Trampal C; Lindsjö L; Ilan E; Danfors T; Antoni G; Sörensen J; Lubberink M
    J Nucl Med; 2018 Jul; 59(7):1152-1158. PubMed ID: 29449445
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Phantom and Clinical Evaluation of the Bayesian Penalized Likelihood Reconstruction Algorithm Q.Clear on an LYSO PET/CT System.
    Teoh EJ; McGowan DR; Macpherson RE; Bradley KM; Gleeson FV
    J Nucl Med; 2015 Sep; 56(9):1447-52. PubMed ID: 26159585
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies.
    Sah BR; Stolzmann P; Delso G; Wollenweber SD; Hüllner M; Hakami YA; Queiroz MA; Barbosa FG; von Schulthess GK; Pietsch C; Veit-Haibach P
    Nucl Med Commun; 2017 Jan; 38(1):57-66. PubMed ID: 27755394
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noise reduction using a Bayesian penalized-likelihood reconstruction algorithm on a time-of-flight PET-CT scanner.
    Caribé PRRV; Koole M; D'Asseler Y; Van Den Broeck B; Vandenberghe S
    EJNMMI Phys; 2019 Dec; 6(1):22. PubMed ID: 31823084
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative performance and optimal regularization parameter in block sequential regularized expectation maximization reconstructions in clinical
    Ter Voert EEGW; Muehlematter UJ; Delso G; Pizzuto DA; Müller J; Nagel HW; Burger IA
    EJNMMI Res; 2018 Jul; 8(1):70. PubMed ID: 30054750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Effect of Various β Values on Image Quality and Semiquantitative Measurements in 68Ga-RM2 and 68Ga-PSMA-11 PET/MRI Images Reconstructed With a Block Sequential Regularized Expectation Maximization Algorithm.
    Baratto L; Duan H; Ferri V; Khalighi M; Iagaru A
    Clin Nucl Med; 2020 Jul; 45(7):506-513. PubMed ID: 32433170
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of image reconstruction method on dose distributions derived from
    Hou X; Ma H; Esquinas PL; Uribe C; Tolhurst S; Bénard F; Liu D; Rahmim A; Celler A
    Phys Med Biol; 2020 Nov; 65(21):215022. PubMed ID: 33245057
    [TBL] [Abstract][Full Text] [Related]  

  • 12.
    Svirydenka H; Muehlematter UJ; Nagel HW; Delso G; Ferraro DA; Kudura K; Burger IA; Ter Voert EEGW
    Eur Radiol; 2020 Jun; 30(6):3188-3197. PubMed ID: 32060711
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of Q.Clear reconstruction on quantification and spatial resolution of 18F-FDG PET in simultaneous PET/MR.
    Tian D; Yang H; Li Y; Cui B; Lu J
    EJNMMI Phys; 2022 Jan; 9(1):1. PubMed ID: 35006411
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative evaluation of PSMA PET imaging using a realistic anthropomorphic phantom and shell-less radioactive epoxy lesions.
    Fedrigo R; Kadrmas DJ; Edem PE; Fougner L; Klyuzhin IS; Petric MP; Bénard F; Rahmim A; Uribe C
    EJNMMI Phys; 2022 Jan; 9(1):2. PubMed ID: 35032234
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Artificial intelligence for detecting small FDG-positive lung nodules in digital PET/CT: impact of image reconstructions on diagnostic performance.
    Schwyzer M; Martini K; Benz DC; Burger IA; Ferraro DA; Kudura K; Treyer V; von Schulthess GK; Kaufmann PA; Huellner MW; Messerli M
    Eur Radiol; 2020 Apr; 30(4):2031-2040. PubMed ID: 31822970
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The value of Bayesian penalized likelihood reconstruction for improving lesion conspicuity of malignant lung tumors on
    Kurita Y; Ichikawa Y; Nakanishi T; Tomita Y; Hasegawa D; Murashima S; Hirano T; Sakuma H
    Ann Nucl Med; 2020 Apr; 34(4):272-279. PubMed ID: 32060780
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of total variation regularized expectation maximization reconstruction on the image quality of
    Yang FJ; Ai SY; Wu R; Lv Y; Xie HF; Dong Y; Meng QL; Wang F
    Br J Radiol; 2021 Apr; 94(1120):20201356. PubMed ID: 33571001
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of optimal regularization factor in Bayesian penalized likelihood reconstruction of brain PET images using [
    Wagatsuma K; Miwa K; Kamitaka Y; Koike E; Yamao T; Yoshii T; Kobayashi R; Nezu S; Sugamata Y; Miyaji N; Imabayashi E; Ishibashi K; Toyohara J; Ishii K
    Med Phys; 2022 May; 49(5):2995-3005. PubMed ID: 35246870
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved [
    Li L; Chen R; Wen J; Yang X; Hu D; Sun H; Ge Q; Ng YL; Zhou Y; Wan L; Chen Y; Wei W; Liu J
    Quant Imaging Med Surg; 2023 Aug; 13(8):5230-5241. PubMed ID: 37581091
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of Bayesian penalized likelihood reconstruction on quantitative and qualitative aspects for pulmonary nodule detection in digital 2-[
    Lohaus N; Enderlin F; Skawran S; Maurer A; Abukwaik AMA; Franzen D; Huellner MW; Messerli M
    Sci Rep; 2022 May; 12(1):8308. PubMed ID: 35585129
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.