123 related articles for article (PubMed ID: 37440682)
1. Comparison of Tumor Bed Delineation Using a Novel Radiopaque Filament Marker Versus Surgical Clips for Targeting Breast Cancer Radiotherapy.
Shukla U; Langner UW; Linshaw D; Tan S; Huber KE; Miller CJ; Yu E; Leonard KL; Sueyoshi M; Diamond B; Edmonson D; Wazer DE; Gass J; Hepel JT
Am J Clin Oncol; 2023 Oct; 46(10):427-432. PubMed ID: 37440682
[TBL] [Abstract][Full Text] [Related]
2. The Effectiveness of Intraoperative Clip Placement in Improving Radiation Therapy Boost Targeting After Oncoplastic Surgery.
Riina MD; Rashad R; Cohen S; Brownlee Z; Sioshansi S; Hepel J; Chatterjee A; Huber KE
Pract Radiat Oncol; 2020; 10(5):e348-e356. PubMed ID: 31866576
[TBL] [Abstract][Full Text] [Related]
3. Tumor bed delineation for partial breast and breast boost radiotherapy planned in the prone position: what does MRI add to X-ray CT localization of titanium clips placed in the excision cavity wall?
Kirby AM; Yarnold JR; Evans PM; Morgan VA; Schmidt MA; Scurr ED; desouza NM
Int J Radiat Oncol Biol Phys; 2009 Jul; 74(4):1276-82. PubMed ID: 19464816
[TBL] [Abstract][Full Text] [Related]
4. Can we rely on surgical clips placed during oncoplastic breast surgery to accurately delineate the tumor bedĀ for targeted breast radiotherapy?
Aldosary G; Caudrelier JM; Arnaout A; Chang L; Tse T; Foottit C; Song J; Belec J; Vandervoort E
Breast Cancer Res Treat; 2021 Apr; 186(2):343-352. PubMed ID: 33484375
[TBL] [Abstract][Full Text] [Related]
5. Analysis of the variability among radiation oncologists in delineation of the postsurgical tumor bed based on 4D-CT.
Wang W; Li J; Xing J; Xu M; Shao Q; Fan T; Guo B; Liu S
Oncotarget; 2016 Oct; 7(43):70516-70523. PubMed ID: 27655639
[TBL] [Abstract][Full Text] [Related]
6. Tumor bed delineation for external beam accelerated partial breast irradiation: a systematic review.
Yang TJ; Tao R; Elkhuizen PH; van Vliet-Vroegindeweij C; Li G; Powell SN
Radiother Oncol; 2013 Aug; 108(2):181-9. PubMed ID: 23806188
[TBL] [Abstract][Full Text] [Related]
7. Interobserver variability (between radiation oncologist and radiation therapist) in tumor bed contouring after breast-conserving surgery.
La Rocca E; Lici V; Giandini T; Bonfantini F; Frasca S; Dispinzieri M; Gennaro M; S DC; Di Cosimo S; Lozza L; Pignoli E; Valdagni R; De Santis MC
Tumori; 2019 Jun; 105(3):210-215. PubMed ID: 30915903
[TBL] [Abstract][Full Text] [Related]
8. Variability among breast radiation oncologists in delineation of the postsurgical lumpectomy cavity.
Landis DM; Luo W; Song J; Bellon JR; Punglia RS; Wong JS; Killoran JH; Gelman R; Harris JR
Int J Radiat Oncol Biol Phys; 2007 Apr; 67(5):1299-308. PubMed ID: 17275202
[TBL] [Abstract][Full Text] [Related]
9. Improvement of consistency in delineating breast lumpectomy cavity using surgical clips.
Atrchian S; Sadeghi P; Cwajna W; Helyer L; Rheaume D; Nolan M; Sadeghi P; Robar J
J Surg Res; 2018 Jan; 221():30-34. PubMed ID: 29229142
[TBL] [Abstract][Full Text] [Related]
10. Definition of Tumor Bed Boost in Oncoplastic Breast Surgery: An Understanding and Approach.
Garreffa E; Hughes-Davies L; Russell S; Lightowlers S; Agrawal A
Clin Breast Cancer; 2020 Aug; 20(4):e510-e515. PubMed ID: 32284305
[TBL] [Abstract][Full Text] [Related]
11. Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation.
Guo B; Li J; Wang W; Xu M; Shao Q; Zhang Y; Liang C; Guo Y
Radiat Oncol; 2015 Mar; 10():66. PubMed ID: 25889620
[TBL] [Abstract][Full Text] [Related]
12. Plastic surgery for breast conservation therapy: how to define the volume of the tumor bed for the boost?
Furet E; Peurien D; Fournier-Bidoz N; Servois V; Reyal F; Fourquet A; Rouzier R; Kirova YM
Eur J Surg Oncol; 2014 Jul; 40(7):830-4. PubMed ID: 24726879
[TBL] [Abstract][Full Text] [Related]
13. Radiographic evaluation of surgical clips is better than ultrasound for defining the lumpectomy cavity in breast boost treatment planning: a prospective clinical study.
Rabinovitch R; Finlayson C; Pan Z; Lewin J; Humphries S; Biffl W; Franciose R
Int J Radiat Oncol Biol Phys; 2000 May; 47(2):313-7. PubMed ID: 10802354
[TBL] [Abstract][Full Text] [Related]
14. Planning the breast boost: how accurately do surgical clips represent the CT seroma?
Yang Z; Chen J; Hu W; Pan Z; Cai G; Yu X; Mei X; Zhang Q; Liu T; Guo X
Radiother Oncol; 2010 Dec; 97(3):530-4. PubMed ID: 20934763
[TBL] [Abstract][Full Text] [Related]
15. The place of the boost in the breast cancer treatment: State of art.
Beddok A; Kirova Y; Laki F; Reyal F; Vincent Salomon A; Servois V; Fourquet A
Radiother Oncol; 2022 May; 170():55-63. PubMed ID: 35307485
[TBL] [Abstract][Full Text] [Related]
16. 3D-conformal accelerated partial breast irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity.
Dzhugashvili M; Tournay E; Pichenot C; Dunant A; Pessoa E; Khallel A; Gouy S; Uzan C; Garbay JR; Rimareix F; Spielmann M; Vielh P; Marsiglia H; Bourgier C
Radiat Oncol; 2009 Dec; 4():70. PubMed ID: 20042124
[TBL] [Abstract][Full Text] [Related]
17. Can initial diagnostic PET-CT aid to localize tumor bed in breast cancer radiotherapy: feasibility study using deformable image registration.
Cho O; Chun M; Oh YT; Kim MH; Park HJ; Heo JS; Noh OK
Radiat Oncol; 2013 Jul; 8():163. PubMed ID: 23822720
[TBL] [Abstract][Full Text] [Related]
18. Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study.
Li XA; Tai A; Arthur DW; Buchholz TA; Macdonald S; Marks LB; Moran JM; Pierce LJ; Rabinovitch R; Taghian A; Vicini F; Woodward W; White JR;
Int J Radiat Oncol Biol Phys; 2009 Mar; 73(3):944-51. PubMed ID: 19215827
[TBL] [Abstract][Full Text] [Related]
19. The validity of surgical clips as a radiographic surrogate for the lumpectomy cavity in image-guided accelerated partial breast irradiation.
Weed DW; Yan D; Martinez AA; Vicini FA; Wilkinson TJ; Wong J
Int J Radiat Oncol Biol Phys; 2004 Oct; 60(2):484-92. PubMed ID: 15380583
[TBL] [Abstract][Full Text] [Related]
20. Tumour bed delineation for partial breast/breast boost radiotherapy: what is the optimal number of implanted markers?
Kirby AN; Jena R; Harris EJ; Evans PM; Crowley C; Gregory DL; Coles CE
Radiother Oncol; 2013 Feb; 106(2):231-5. PubMed ID: 23490269
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]