These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
114 related articles for article (PubMed ID: 37458054)
1. Analysis of cardiovascular function in diabetic patients using EEMD-ICA fusion multi-scale percussion entropy. Li MM; Pan JX; Wang JH; Hu ZL; Zhao J; Wei HC Technol Health Care; 2024; 32(2):809-821. PubMed ID: 37458054 [TBL] [Abstract][Full Text] [Related]
2. Noise reduction and QRS detection in ECG signal using EEMD with modified sigmoid thresholding. Mohguen O Biomed Tech (Berl); 2024 Feb; 69(1):61-78. PubMed ID: 37665599 [TBL] [Abstract][Full Text] [Related]
3. [Research on heart rate extraction algorithm in motion state based on normalized least mean square combining ensemble empirical mode decomposition]. Geng D; Zhao J; Wang C; Dong J; Ning Q; Wang Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2020 Feb; 37(1):71-79. PubMed ID: 32096379 [TBL] [Abstract][Full Text] [Related]
4. [Research on ECG de-noising method based on ensemble empirical mode decomposition and wavelet transform using improved threshold function]. Ye L; Yang D; Wang X Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2014 Jun; 31(3):567-71. PubMed ID: 25219236 [TBL] [Abstract][Full Text] [Related]
5. [EEMD-ICA Applied in Signal Extraction in Functional Near-Infrared Spectroscopy]. Zha YT; Liu GD; Zhou RD; Zhang XF; Niu JQ; Yu Y; Wang W Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Oct; 35(10):2746-51. PubMed ID: 26904811 [TBL] [Abstract][Full Text] [Related]
6. Automatic selection of IMFs to denoise the sEMG signals using EMD. Koppolu PK; Chemmangat K J Electromyogr Kinesiol; 2023 Dec; 73():102834. PubMed ID: 37922679 [TBL] [Abstract][Full Text] [Related]
7. Genetic particle filter improved fuzzy-AEEMD for ECG signal de-noising. Kapoor R; Birok R Comput Methods Biomech Biomed Engin; 2021 Oct; 24(13):1426-1436. PubMed ID: 33667141 [TBL] [Abstract][Full Text] [Related]
8. SVR-EEMD: An Improved EEMD Method Based on Support Vector Regression Extension in PPG Signal Denoising. Liu G; Hu X; Wang E; Zhou G; Cai J; Zhang S Comput Math Methods Med; 2019; 2019():5363712. PubMed ID: 31915461 [TBL] [Abstract][Full Text] [Related]
9. A Novel Hybrid Approach for Partial Discharge Signal Detection Based on Complete Ensemble Empirical Mode Decomposition with Adaptive Noise and Approximate Entropy. Shang H; Li Y; Xu J; Qi B; Yin J Entropy (Basel); 2020 Sep; 22(9):. PubMed ID: 33286808 [TBL] [Abstract][Full Text] [Related]
10. Noise Reduction Method of Underwater Acoustic Signals Based on Uniform Phase Empirical Mode Decomposition, Amplitude-Aware Permutation Entropy, and Pearson Correlation Coefficient. Li G; Yang Z; Yang H Entropy (Basel); 2018 Nov; 20(12):. PubMed ID: 33266642 [TBL] [Abstract][Full Text] [Related]
11. Estimating Heart Rate and Respiratory Rate from a Single Lead Electrocardiogram Using Ensemble Empirical Mode Decomposition and Spectral Data Fusion. Chung IQ; Yu JT; Hu WC Sensors (Basel); 2021 Feb; 21(4):. PubMed ID: 33567575 [TBL] [Abstract][Full Text] [Related]
12. Early Detection of Sudden Cardiac Death by Using Ensemble Empirical Mode Decomposition-Based Entropy and Classical Linear Features From Heart Rate Variability Signals. Shi M; He H; Geng W; Wu R; Zhan C; Jin Y; Zhu F; Ren S; Shen B Front Physiol; 2020; 11():118. PubMed ID: 32158399 [TBL] [Abstract][Full Text] [Related]
13. An EEMD-ICA Approach to Enhancing Artifact Rejection for Noisy Multivariate Neural Data. Zeng K; Chen D; Ouyang G; Wang L; Liu X; Li X IEEE Trans Neural Syst Rehabil Eng; 2016 Jun; 24(6):630-8. PubMed ID: 26552089 [TBL] [Abstract][Full Text] [Related]
14. A Novel Method Based on Combination of Independent Component Analysis and Ensemble Empirical Mode Decomposition for Removing Electrooculogram Artifacts From Multichannel Electroencephalogram Signals. Teng CL; Zhang YY; Wang W; Luo YY; Wang G; Xu J Front Neurosci; 2021; 15():729403. PubMed ID: 34707475 [TBL] [Abstract][Full Text] [Related]
15. A hybrid denoising approach for PPG signals utilizing variational mode decomposition and improved wavelet thresholding. Hu Q; Li M; Jiang L; Liu M Technol Health Care; 2024; 32(4):2793-2814. PubMed ID: 38517823 [TBL] [Abstract][Full Text] [Related]
16. An EEMD-PCA approach to extract heart rate, respiratory rate and respiratory activity from PPG signal. Motin MA; Karmakar CK; Palaniswami M Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3817-3820. PubMed ID: 28269118 [TBL] [Abstract][Full Text] [Related]
17. Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect. Mariyappa N; Sengottuvel S; Parasakthi C; Gireesan K; Janawadkar MP; Radhakrishnan TS; Sundar CS Med Eng Phys; 2014 Oct; 36(10):1266-76. PubMed ID: 25074650 [TBL] [Abstract][Full Text] [Related]
18. Application of EEMD and improved frequency band entropy in bearing fault feature extraction. Li H; Liu T; Wu X; Chen Q ISA Trans; 2019 May; 88():170-185. PubMed ID: 30558907 [TBL] [Abstract][Full Text] [Related]
19. Noise Reduction Method of Underwater Acoustic Signals Based on CEEMDAN, Effort-To-Compress Complexity, Refined Composite Multiscale Dispersion Entropy and Wavelet Threshold Denoising. Li G; Guan Q; Yang H Entropy (Basel); 2018 Dec; 21(1):. PubMed ID: 33266727 [TBL] [Abstract][Full Text] [Related]
20. Fault Diagnosis for Analog Circuits by Using EEMD, Relative Entropy, and ELM. Xiong J; Tian S; Yang C Comput Intell Neurosci; 2016; 2016():7657054. PubMed ID: 27698663 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]