BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 37458636)

  • 21. Comparison of ultrasound-guided biopsy technique for thyroid nodules with respect to adequacy of cytological material.
    Kandil E; Khalek MA; Alabbas H; Moroz K; Islam T; Friedlander P; Jaffe BM
    ORL J Otorhinolaryngol Relat Spec; 2011; 73(4):177-81. PubMed ID: 21625193
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ultrasound-guided fine-needle aspiration biopsy of thyroid nodules: comparison in efficacy according to nodule size.
    Kim DW; Lee EJ; Kim SH; Kim TH; Lee SH; Kim DH; Rho MH
    Thyroid; 2009 Jan; 19(1):27-31. PubMed ID: 19021460
    [TBL] [Abstract][Full Text] [Related]  

  • 23. THE VALUE OF GROSS VISUAL ASSESSMENT OF SPECIMEN ADEQUACY FOR LIQUID-BASED CYTOLOGY DURING ULTRASOUND-GUIDED, FINE-NEEDLE ASPIRATION OF THYROID NODULES.
    Moon WJ; Baek JH; Choi JW; Kim YJ; Ha EJ; Lim HK; Song DE; Lee JH; Shong YK
    Endocr Pract; 2015 Nov; 21(11):1219-26. PubMed ID: 26214114
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Needle size and sample adequacy in ultrasound-guided biopsy of thyroid nodules.
    Hanbidge AE; Arenson AM; Shaw PA; Szalai JP; Hamilton PA; Leonhardt C
    Can Assoc Radiol J; 1995 Jun; 46(3):199-201. PubMed ID: 7538881
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of Number of Passes and Cytopathological Specimen Adequacy for Thyroid Fine-Needle Aspiration Biopsy in the Absence of an On-Site Pathologist.
    Kuzan TY; Canbey Goret C
    Eur Thyroid J; 2020 Jan; 9(1):49-54. PubMed ID: 32071902
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Ultrasonography-guided fine-needle aspiration cytology for thyroid nodules: an emphasis on one-sampling and biopsy techniques.
    Kim DW; Choo HJ; Park JS; Lee EJ; Kim SH; Jung SJ; Ryu JH
    Diagn Cytopathol; 2012 May; 40 Suppl 1():E48-54. PubMed ID: 21416648
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Diagnostic utility of fine needle aspiration cytology in pediatric thyroid nodules based on Bethesda Classification.
    Jiang W; Phillips SA; Newbury RO; Naheedy JH; Newfield RS
    J Pediatr Endocrinol Metab; 2021 Apr; 34(4):449-455. PubMed ID: 33629571
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Follow-Up Strategies for Thyroid Nodules with Benign Cytology on Ultrasound-Guided Fine Needle Aspiration: Malignancy Rates of Management Guidelines Using Ultrasound Before and After the Era of the Bethesda System.
    Yoon JH; Lee HS; Kim EK; Moon HJ; Park VY; Kwak JY
    Thyroid; 2019 Sep; 29(9):1227-1236. PubMed ID: 31359839
    [No Abstract]   [Full Text] [Related]  

  • 29. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.
    Dong Y; Mao M; Zhan W; Zhou J; Zhou W; Yao J; Hu Y; Wang Y; Ye T
    J Ultrasound Med; 2018 Jun; 37(6):1367-1377. PubMed ID: 29120064
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ultrasound-guided fine needle aspiration of thyroid nodules with on-site cytological examination: Diagnostic efficacy, prevalence, and factors predicting for Bethesda category I results.
    García Pascual L; Surralles ML; Morlius X; González Mínguez C; Viscasillas G; Lao X
    Endocrinol Diabetes Nutr (Engl Ed); 2019 Oct; 66(8):495-501. PubMed ID: 30858021
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ultrasound features affecting the sample adequacy after fine-needle aspiration of thyroid nodules with different risk stratification.
    Chen Z; Qiu ZX; Guo DM; Wang JJ; Guo HT; Su HH; Dai ZZ; Zhai YX
    Clin Hemorheol Microcirc; 2023; 83(4):377-386. PubMed ID: 36744332
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Thyroid Ultrasound-Guided Fine-Needle Aspiration Cytology Results: Observed Increase in Indeterminate Rate over the Past Decade.
    Manning AM; Yang H; Falciglia M; Mark JR; Steward DL
    Otolaryngol Head Neck Surg; 2017 Apr; 156(4):611-615. PubMed ID: 28118554
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ultrasound-guided thyroid nodule fine-needle biopsies--comparison of sample adequacy with different sampling techniques, different needle sizes, and with/without onsite cytological analysis.
    Cerit M; Yücel C; Göçün PU; Poyraz A; Cerit ET; Taneri F
    Endokrynol Pol; 2015; 66(4):295-300. PubMed ID: 26323465
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Diagnostic adequacy of surgeon-performed ultrasound-guided fine needle aspiration biopsy of thyroid nodules.
    Karadeniz Cakmak G; Emre AU; Tascilar O; Gultekin FA; Ozdamar SO; Comert M
    J Surg Oncol; 2013 Feb; 107(2):206-10. PubMed ID: 22766655
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Value of rapid on-site evaluation for ultrasound-guided thyroid fine needle aspiration.
    Jiang D; Zang Y; Jiang D; Zhang X; Zhao C
    J Int Med Res; 2019 Feb; 47(2):626-634. PubMed ID: 30463462
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of cytological adequacy and pain scale score in ultrasound-guided fine-needle aspiration of solid thyroid nodules for liquid-based cytology with with 23- and 25-gauge needles: a single-center prospective study.
    Lee YJ; Kim DW; Shin GW; Heo YJ; Baek JW; Choo HJ; Cho YJ; Jung SJ; Baek HJ
    Sci Rep; 2019 May; 9(1):7027. PubMed ID: 31065031
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ultrasound-guided fine-needle aspiration of thyroid nodules: does the size limit its efficiency?
    Zhong LC; Lu F; Ma F; Xu HX; Li DD; Guo LH; Sun LP
    Int J Clin Exp Pathol; 2015; 8(3):3155-9. PubMed ID: 26045833
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Use of strain ultrasound elastography versus fine-needle aspiration cytology for the differential diagnosis of thyroid nodules: a retrospective analysis.
    Yang X; Zhai D; Zhang T; Zhang S
    Clinics (Sao Paulo); 2020; 75():e1594. PubMed ID: 32578823
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Frequencies and malignancy rates of 6-tiered Bethesda categories of thyroid nodules according to ultrasound assessment and nodule size.
    Park VY; Lee HS; Kim EK; Kwak JY; Yoon JH; Moon HJ
    Head Neck; 2018 Sep; 40(9):1947-1954. PubMed ID: 29684254
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of fine needle aspiration and non-aspiration cytology for diagnosis of thyroid nodules: A prospective, randomized, and controlled trial.
    Wang D; Fu HJ; Xu HX; Guo LH; Li XL; He YP; Bo XW; Zhao CK; Sun LP; Lu F; Zhang K; Wei Q
    Clin Hemorheol Microcirc; 2017; 66(1):67-81. PubMed ID: 28128748
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.