These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 3746371)

  • 1. Minimizing interference and false alarms from electrocautery in the Nellcor N-100 pulse oximeter.
    Block FE; Detko GJ
    J Clin Monit; 1986 Jul; 2(3):203-5. PubMed ID: 3746371
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Advanced pulse oximeter signal processing technology compared to simple averaging. II. Effect on frequency of alarms in the postanesthesia care unit.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Anesth; 1999 May; 11(3):196-200. PubMed ID: 10434214
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Advanced pulse oximeter signal processing technology compared to simple averaging. I. Effect on frequency of alarms in the operating room.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Anesth; 1999 May; 11(3):192-5. PubMed ID: 10434213
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous pulse oximetry in the general surgical ward: Nellcor N-200 versus Nellcor N-3000.
    Christensen M; Lie C; Rosenberg J
    Anaesthesia; 1999 Mar; 54(3):253-7. PubMed ID: 10364861
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Monit Comput; 1998 Apr; 14(3):151-6. PubMed ID: 9676861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance.
    Stefanescu BM; O'Shea TM; Haury F; Carlo WA; Slaughter JC
    Respir Care; 2016 Jan; 61(1):85-9. PubMed ID: 26508772
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of motion on the performance of pulse oximeters in volunteers.
    Barker SJ; Shah NK
    Anesthesiology; 1996 Oct; 85(4):774-81. PubMed ID: 8873547
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reliability of conventional and new pulse oximetry in neonatal patients.
    Hay WW; Rodden DJ; Collins SM; Melara DL; Hale KA; Fashaw LM
    J Perinatol; 2002; 22(5):360-6. PubMed ID: 12082469
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Postanesthesia monitoring revisited: frequency of true and false alarms from different monitoring devices.
    Wiklund L; Hök B; Ståhl K; Jordeby-Jönsson A
    J Clin Anesth; 1994; 6(3):182-8. PubMed ID: 8060626
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.
    Workie FA; Rais-Bahrami K; Short BL
    Am J Perinatol; 2005 Oct; 22(7):357-60. PubMed ID: 16215921
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prospective comparison of 3 new-generation pulse oximetry devices during ambulation after open heart surgery.
    Richards NM; Giuliano KK; Jones PG
    Respir Care; 2006 Jan; 51(1):29-35. PubMed ID: 16381614
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.
    Nizami S; Greenwood K; Barrowman N; Harrold J
    Cardiovasc Eng Technol; 2015 Sep; 6(3):383-91. PubMed ID: 26577369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring.
    Nassi N; Piumelli R; Lombardi E; Landini L; Donzelli G; de Martino M
    Arch Dis Child; 2008 Feb; 93(2):126-32. PubMed ID: 17893118
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters.
    Bohnhorst B; Peter CS; Poets CF
    Crit Care Med; 2000 May; 28(5):1565-8. PubMed ID: 10834712
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Differences in pulse oximetry technology can affect detection of sleep-disorderd breathing in children.
    Brouillette RT; Lavergne J; Leimanis A; Nixon GM; Ladan S; McGregor CD
    Anesth Analg; 2002 Jan; 94(1 Suppl):S47-53. PubMed ID: 11900039
    [TBL] [Abstract][Full Text] [Related]  

  • 16. False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET technology in the pediatric postanesthesia care unit.
    Malviya S; Reynolds PI; Voepel-Lewis T; Siewert M; Watson D; Tait AR; Tremper K
    Anesth Analg; 2000 Jun; 90(6):1336-40. PubMed ID: 10825316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of a third (Dolphin Voyager) versus first generation pulse oximeter (Nellcor N-180) in predicting arterial oxygen saturation and pulse rate in the anesthetized dog.
    Burns PM; Driessen B; Boston R; Gunther RA
    Vet Anaesth Analg; 2006 Sep; 33(5):281-95. PubMed ID: 16916350
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effects of motion on the performance of pulse oximeters in volunteers (revised publication).
    Barker SJ; Shah NK
    Anesthesiology; 1997 Jan; 86(1):101-8. PubMed ID: 9009945
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Alarm settings for the Marquette 8000 pulse oximeter to prevent hyperoxic and hypoxic episodes.
    Cust AE; Donovan TJ; Colditz PB
    J Paediatr Child Health; 1999 Apr; 35(2):159-62. PubMed ID: 10365353
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery room.
    Rheineck-Leyssius AT; Kalkman CJ
    Br J Anaesth; 1997 Oct; 79(4):460-4. PubMed ID: 9389263
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.