BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

347 related articles for article (PubMed ID: 37464106)

  • 21. Endoscopic Ultrasound-guided Sampling of Solid Pancreatic Lesions: A Comparative Analysis of 25 Gauge
    Siddique DA; Rahal MA; Trevino K; Wu HH; Al-Haddad MA
    Anticancer Res; 2020 Oct; 40(10):5845-5851. PubMed ID: 32988914
    [TBL] [Abstract][Full Text] [Related]  

  • 22. High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions.
    Iwashita T; Nakai Y; Samarasena JB; Park DH; Zhang Z; Gu M; Lee JG; Chang KJ
    Gastrointest Endosc; 2013 Jun; 77(6):909-15. PubMed ID: 23433596
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) in insulinomas: Indications and clinical relevance in a single investigator cohort of 47 patients.
    Kann PH; Moll R; Bartsch D; Pfützner A; Forst T; Tamagno G; Goebel JN; Fourkiotis V; Bergmann SR; Collienne M
    Endocrine; 2017 Apr; 56(1):158-163. PubMed ID: 27905047
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of the Diagnostic Performance of Newly Designed 21-Gauge and Standard 22-Gauge Aspiration Needles in Patients with Solid Pancreatic Masses.
    Minaga K; Yoshikawa T; Yamashita Y; Akamatsu H; Ikenouchi M; Ishii T; Matsumoto H; Iwagami H; Nakatani Y; Hatamaru K; Takenaka M; Akamatsu T; Uenoyama Y; Watanabe T; Ono K; Chiba Y; Kudo M
    Dig Dis Sci; 2019 Oct; 64(10):2982-2991. PubMed ID: 31011943
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Does ProCore Fine-Needle Biopsy Really Improve the Clinical Outcome of Endoscopic Ultrasound-Guided Sampling of Pancreatic Masses?
    Delconte G; Cavalcoli F; Magarotto A; Centonze G; Bezzio C; Cattaneo L; Rausa E; Kelly ME; Bonitta G; Milione M; Enzo M
    Dig Dis; 2022; 40(1):78-84. PubMed ID: 33780932
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Endoscopic ultrasound-guided tissue acquisition of solid mass lesions of the pancreas: A retrospective comparison study of fine-needle aspiration and fine-needle biopsy.
    Sweeney J; Soong L; Goyal A
    Diagn Cytopathol; 2020 Apr; 48(4):322-329. PubMed ID: 31903736
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Features of chronic pancreatitis by endoscopic ultrasound influence the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration of small pancreatic lesions.
    Kurita Y; Kuwahara T; Hara K; Mizuno N; Okuno N; Matsumoto S; Obata M; Koda H; Tajika M; Shimizu Y; Nakajima A; Kubota K; Niwa Y
    Dig Endosc; 2020 Mar; 32(3):399-408. PubMed ID: 31361926
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Fine-Needle Biopsy in the Diagnosis of Solid Pancreatic Lesions.
    Ayres LR; Kmiotek EK; Lam E; Telford JJ
    Can J Gastroenterol Hepatol; 2018; 2018():1415062. PubMed ID: 29850451
    [TBL] [Abstract][Full Text] [Related]  

  • 29. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
    Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
    Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of Pancreatic Lesions With Endoscopic Ultrasound and Fine Needle Aspiration.
    Luk Y; She WH; Chow FCL; Ma KW; Tsang SHY; Dai WC; Cheung TT; Lo CM
    Surg Innov; 2020 Oct; 27(5):431-438. PubMed ID: 32476606
    [No Abstract]   [Full Text] [Related]  

  • 31. Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions.
    Berzosa M; Villa N; El-Serag HB; Sejpal DV; Patel KK
    Endosc Ultrasound; 2015; 4(1):28-33. PubMed ID: 25789281
    [TBL] [Abstract][Full Text] [Related]  

  • 32. EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms.
    Strand DS; Jeffus SK; Sauer BG; Wang AY; Stelow EB; Shami VM
    Diagn Cytopathol; 2014 Sep; 42(9):751-8. PubMed ID: 24550162
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study.
    Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Cha SW; Cho YD; Park SH
    Endoscopy; 2014 Dec; 46(12):1056-62. PubMed ID: 25098611
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In memoriam: Fine-needle aspiration, birth: Fine-needle biopsy: The changing trend in endoscopic ultrasound-guided tissue acquisition.
    Bang JY; Kirtane S; Krall K; Navaneethan U; Hasan M; Hawes R; Varadarajulu S
    Dig Endosc; 2019 Mar; 31(2):197-202. PubMed ID: 30256458
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.
    Siddiqui AA; Brown LJ; Hong SK; Draganova-Tacheva RA; Korenblit J; Loren DE; Kowalski TE; Solomides C
    Dig Dis Sci; 2011 Nov; 56(11):3370-5. PubMed ID: 21688127
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Diagnostic value of SpyGlass for pancreatic cystic lesions: comparison of EUS-guided fine-needle aspiration and EUS-guided fine-needle aspiration combined with SpyGlass.
    Du C; Chai N; Linghu E; Li H; Feng X; Wang X; Tang P
    Surg Endosc; 2022 Feb; 36(2):904-910. PubMed ID: 33650000
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The usefulness of EUS-FNA with contrast-enhanced harmonic imaging of solid pancreatic lesions: A prospective study.
    Itonaga M; Kitano M; Kojima F; Hatamaru K; Yamashita Y; Tamura T; Nuta J; Kawaji Y; Shimokawa T; Tanioka K; Murata SI
    J Gastroenterol Hepatol; 2020 Dec; 35(12):2273-2280. PubMed ID: 32529685
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A pilot study of EUS-guided through-the-needle forceps biopsy (with video).
    Nakai Y; Isayama H; Chang KJ; Yamamoto N; Mizuno S; Mohri D; Kogure H; Matsubara S; Tada M; Koike K
    Gastrointest Endosc; 2016 Jul; 84(1):158-62. PubMed ID: 26772889
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Diagnostic ability and factors affecting accuracy of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid lesions: Japanese large single center experience.
    Haba S; Yamao K; Bhatia V; Mizuno N; Hara K; Hijioka S; Imaoka H; Niwa Y; Tajika M; Kondo S; Tanaka T; Shimizu Y; Yatabe Y; Hosoda W; Kawakami H; Sakamoto N
    J Gastroenterol; 2013 Aug; 48(8):973-81. PubMed ID: 23090002
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of endoscopic ultrasound-guided fine-needle biopsy for preoperative pancreatic solid lesions.
    Fujita A; Ryozawa S; Tanisaka Y; Ogawa T; Suzuki M; Katsuda H; Tashima T; Araki R; Mizuide M
    Scand J Gastroenterol; 2021 Feb; 56(2):188-192. PubMed ID: 33295211
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.