These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 37469178)

  • 41. Evaluating Accuracy of Numerical Simulations in Predicting Heating of Wire Implants During MRI at 1.5 T.
    Vu J; Bhusal B; Nguyen BT; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():6107-6110. PubMed ID: 33019364
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.
    Bhidayasiri R; Bronstein JM; Sinha S; Krahl SE; Ahn S; Behnke EJ; Cohen MS; Frysinger R; Shellock FG
    Magn Reson Imaging; 2005 May; 23(4):549-55. PubMed ID: 15919600
    [TBL] [Abstract][Full Text] [Related]  

  • 43. MRI-based transfer function determination for the assessment of implant safety.
    Tokaya JP; Raaijmakers AJE; Luijten PR; Bakker JF; van den Berg CAT
    Magn Reson Med; 2017 Dec; 78(6):2449-2459. PubMed ID: 28164362
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A simple geometric analysis method for measuring and mitigating RF induced currents on Deep Brain Stimulation leads by multichannel transmission/reception.
    Eryaman Y; Kobayashi N; Moen S; Aman J; Grant A; Vaughan JT; Molnar G; Park MC; Vitek J; Adriany G; Ugurbil K; Harel N
    Neuroimage; 2019 Jan; 184():658-668. PubMed ID: 30273715
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A numerical and experimental study of RF shimming in the presence of hip prostheses using adaptive SAR at 3 T.
    Destruel A; Fuentes M; Weber E; O'Brien K; Jin J; Liu F; Barth M; Crozier S
    Magn Reson Med; 2019 Jun; 81(6):3826-3839. PubMed ID: 30803001
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Animal studies in clinical MRI scanners: A custom setup for combined fMRI and deep-brain stimulation in awake rats.
    Derksen M; Rhemrev V; van der Veer M; Jolink L; Zuidinga B; Mulder T; Reneman L; Nederveen A; Feenstra M; Willuhn I; Denys D
    J Neurosci Methods; 2021 Aug; 360():109240. PubMed ID: 34097929
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Ultrahigh-Magnitude Brain Magnetic Resonance Imaging Scan on Rhesus Monkeys With Implanted Deep Brain Stimulation Hardware.
    Li JJ; Shi L; Chen YC; Zhu GY; Zhang JG
    Neuromodulation; 2018 Feb; 21(2):168-175. PubMed ID: 29219219
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners.
    Cabot E; Lloyd T; Christ A; Kainz W; Douglas M; Stenzel G; Wedan S; Kuster N
    Bioelectromagnetics; 2013 Feb; 34(2):104-13. PubMed ID: 23060256
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The Safety of Using Body-Transmit MRI in Patients with Implanted Deep Brain Stimulation Devices.
    Kahan J; Papadaki A; White M; Mancini L; Yousry T; Zrinzo L; Limousin P; Hariz M; Foltynie T; Thornton J
    PLoS One; 2015; 10(6):e0129077. PubMed ID: 26061738
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Adaptive SAR mass-averaging framework to improve predictions of local RF heating near a hip implant for parallel transmit at 7 T.
    Destruel A; O'Brien K; Jin J; Liu F; Barth M; Crozier S
    Magn Reson Med; 2019 Jan; 81(1):615-627. PubMed ID: 30058186
    [TBL] [Abstract][Full Text] [Related]  

  • 51. RF-induced heating for active implantable medical devices in dual parallel leads configurations at 1.5 T MRI.
    Hu W; Guo R; Wang Q; Zheng J; Tsang J; Kainz W; Long S; Chen J
    Magn Reson Med; 2023 Aug; 90(2):686-698. PubMed ID: 37036364
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Application of Machine learning to predict RF heating of cardiac leads during magnetic resonance imaging at 1.5 T and 3 T: A simulation study.
    Chen X; Zheng C; Golestanirad L
    J Magn Reson; 2023 Apr; 349():107384. PubMed ID: 36842429
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Improving Safety of MRI in Patients with Deep Brain Stimulation Devices.
    Boutet A; Chow CT; Narang K; Elias GJB; Neudorfer C; Germann J; Ranjan M; Loh A; Martin AJ; Kucharczyk W; Steele CJ; Hancu I; Rezai AR; Lozano AM
    Radiology; 2020 Aug; 296(2):250-262. PubMed ID: 32573388
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Parallel transmit pulse design for patients with deep brain stimulation implants.
    Eryaman Y; Guerin B; Akgun C; Herraiz JL; Martin A; Torrado-Carvajal A; Malpica N; Hernandez-Tamames JA; Schiavi E; Adalsteinsson E; Wald LL
    Magn Reson Med; 2015 May; 73(5):1896-903. PubMed ID: 24947104
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Low-field MRI's Spark on Implant Safety: A Closer Look at Radiofrequency Heating.
    Sanpitak P; Bhusal B; Vu J; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-5. PubMed ID: 38083021
    [TBL] [Abstract][Full Text] [Related]  

  • 56. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI.
    Córcoles J; Zastrow E; Kuster N
    Phys Med Biol; 2017 Jun; 62(12):4711-4727. PubMed ID: 28252443
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Three-Tesla Magnetic Resonance Imaging of Patients With Deep Brain Stimulators: Results From a Phantom Study and a Pilot Study in Patients.
    Davidson B; Tam F; Yang B; Meng Y; Hamani C; Graham SJ; Lipsman N
    Neurosurgery; 2021 Jan; 88(2):349-355. PubMed ID: 33045736
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
    Winter L; Özerdem C; Hoffmann W; Santoro D; Müller A; Waiczies H; Seemann R; Graessl A; Wust P; Niendorf T
    PLoS One; 2013; 8(4):e61661. PubMed ID: 23613896
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device.
    Baker KB; Tkach J; Hall JD; Nyenhuis JA; Shellock FG; Rezai AR
    Neurosurgery; 2005 Oct; 57(4 Suppl):392-7; discussion 392-7. PubMed ID: 16234691
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating.
    Gudino N; Sonmez M; Yao Z; Baig T; Nielles-Vallespin S; Faranesh AZ; Lederman RJ; Martens M; Balaban RS; Hansen MS; Griswold MA
    Med Phys; 2015 Jan; 42(1):359-71. PubMed ID: 25563276
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.