These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 37471587)

  • 1. 5-Year haemodynamic performance of three aortic bioprostheses. A randomized clinical trial.
    Montero Cruces L; Carnero Alcázar M; Pérez Camargo D; Cobiella Carnicer J; Campelos Fernández P; Reguillo Lacruz FJ; Maroto Castellanos LC
    Eur J Cardiothorac Surg; 2023 Aug; 64(2):. PubMed ID: 37471587
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Randomized comparison of exercise haemodynamics of Freestyle, Magna Ease and Trifecta bioprostheses after aortic valve replacement for severe aortic stenosis.
    Bach DS; Patel HJ; Kolias TJ; Deeb GM
    Eur J Cardiothorac Surg; 2016 Aug; 50(2):361-7. PubMed ID: 26819292
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The TRIBECA study: (TRI)fecta (B)ioprosthesis (E)valuation versus (C)arpentier Magna-Ease in (A)ortic position.
    Colli A; Marchetto G; Salizzoni S; Rinaldi M; Di Marco L; Pacini D; Di Bartolomeo R; Nicolini F; Gherli T; Agrifoglio M; Borghetti V; Khoury G; De Paolis M; Zoffoli G; Mangino D; Amorim MJ; Manzan E; Zucchetta F; Balduzzi S; Gerosa G
    Eur J Cardiothorac Surg; 2016 Feb; 49(2):478-85. PubMed ID: 25769464
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Trifecta versus Perimount Magna Ease aortic valves: Failure mechanisms.
    Suzuki R; Ito T; Suzuki M; Ohori S; Takayanagi R; Miura S
    Asian Cardiovasc Thorac Ann; 2022 Sep; 30(7):797-806. PubMed ID: 35603636
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: is there a hemodynamic superiority?
    Wendt D; Thielmann M; Plicht B; Aßmann J; Price V; Neuhäuser M; Jakob H
    J Thorac Cardiovasc Surg; 2014 May; 147(5):1553-60. PubMed ID: 23870159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Trifecta Versus Perimount Magna Ease Aortic Valve Prostheses.
    Biancari F; Valtola A; Juvonen T; Husso A; Dahlbacka S; Laakso T; Jalava MP; Tauriainen T; Ahvenvaara T; Kinnunen EM; Niemelä M; Mäkikallio T; Eskola M; Virtanen MPO; Maaranen P; Rosato S; Anttila V; Vento A; Airaksinen J; Raivio P
    Ann Thorac Surg; 2020 Sep; 110(3):879-888. PubMed ID: 32061588
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Trifecta and Carpentier Edwards aortic bioprostheses: Comparison of six years follow-up outcomes.
    Pfister R; Frey V; Kirsch M; Tozzi P; Delay D; Gunga Z; Prêtre R; Niclauss L
    Asian Cardiovasc Thorac Ann; 2023 May; 31(4):312-320. PubMed ID: 36991560
    [TBL] [Abstract][Full Text] [Related]  

  • 8. One-Year Hemodynamic Performance of Three Cardiac Aortic Bioprostheses: A Randomized Comparative Clinical Trial.
    Montero-Cruces L; Carnero-Alcázar M; Reguillo-Lacruz FJ; Cobiella-Carnicer FJ; Pérez-Camargo D; Campelos-Fernández P; Maroto-Castellanos LC
    J Clin Med; 2021 Nov; 10(22):. PubMed ID: 34830622
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fluid-dynamic results of in vitro comparison of four pericardial bioprostheses implanted in small porcine aortic roots.
    Tasca G; Vismara R; Fiore GB; Mangini A; Romagnoni C; Pelenghi S; Antona C; Redaelli A; Gamba A
    Eur J Cardiothorac Surg; 2015 Feb; 47(2):e62-7. PubMed ID: 25414428
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses.
    Ugur M; Suri RM; Daly RC; Dearani JA; Park SJ; Joyce LD; Burkhart HM; Greason KL; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Nov; 148(5):1940-6. PubMed ID: 24530199
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Magna ease bioprosthetic aortic valve: mid-term haemodynamic outcomes in 1126 patients.
    Thorp SD; Khazaal J; Yu G; Parker JL; Timek TA
    Interact Cardiovasc Thorac Surg; 2021 May; 32(6):839-845. PubMed ID: 33570145
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemodynamic performance of the Medtronic Mosaic and Perimount Magna aortic bioprostheses: five-year results of a prospectively randomized study.
    Dalmau MJ; González-Santos JM; Blázquez JA; Sastre JA; López-Rodríguez J; Bueno M; Castaño M; Arribas A
    Eur J Cardiothorac Surg; 2011 Jun; 39(6):844-52; discussion 852. PubMed ID: 21193320
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reintervention After Aortic Valve Replacement: Comparison of 3 Aortic Bioprostheses.
    Lam KY; Koene B; Timmermans N; Soliman-Hamad M; van Straten A
    Ann Thorac Surg; 2020 Aug; 110(2):615-621. PubMed ID: 31846642
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early in-vivo hemodynamic comparison of supra-annular aortic bioprostheses: Trifecta versus Perimount Magna Ease.
    Modi A; Pousios D; Sadeque S; Velissaris T; Barlow C; Livesey S; Tsang GM; Ohri SK
    J Heart Valve Dis; 2014 May; 23(3):325-32. PubMed ID: 25296457
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus.
    Domoto S; Niinami H; Uwabe K; Koike H; Tabata M; Morita K; Kambe M; Iguchi A
    Interact Cardiovasc Thorac Surg; 2016 Jan; 22(1):19-25. PubMed ID: 26467641
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Aortic valve biologic protheses: A cohort comparison of premature valve failure.
    Yount KW; Hawkins RB; Mehaffey JH; Teman NR; Yarboro LT; Kern JA; Ailawadi G
    J Card Surg; 2022 May; 37(5):1224-1229. PubMed ID: 35245397
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Randomized (CO)mparison of (TRI)fecta and (P)erimount Magna Ease Supraannular Aortic Xenografts-CO.TRI.P Study.
    Van Linden A; Arsalan M; Körschgen T; Blumenstein J; Kempfert J; Hecker F; Walther T
    Thorac Cardiovasc Surg; 2019 Jun; 67(4):266-273. PubMed ID: 29715705
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early haemodynamic performance of a latest generation supra-annular aortic bioprosthesis: experience from a large single-centre series.
    Deutsch MA; Prinzing A; Fiegl K; Wottke M; Badiu CC; Krane M; Goppel G; Bleiziffer S; Guenzinger R; Lange R
    Eur J Cardiothorac Surg; 2016 Jun; 49(6):1691-8. PubMed ID: 26656235
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.
    Tasca G; Stefano A; Giannico F; Lobiati E; Riva B; Galanti A; Triggiani M; Gamba A
    J Heart Valve Dis; 2014 Sep; 23(5):633-41. PubMed ID: 25799714
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.