167 related articles for article (PubMed ID: 37478713)
1. Unsteady blood flow of Carreau fluid in a porous saturated medium with stenosis under the influence of acceleration and magnetic fields: A comprehensive analysis.
Fahim M; Sajid M; Ali N; Naveed M
Comput Biol Med; 2023 Sep; 164():107278. PubMed ID: 37478713
[TBL] [Abstract][Full Text] [Related]
2. Nonlinear model on pulsatile flow of blood through a porous bifurcated arterial stenosis in the presence of magnetic field and periodic body acceleration.
Ponalagusamy R; Priyadharshini S
Comput Methods Programs Biomed; 2017 Apr; 142():31-41. PubMed ID: 28325445
[TBL] [Abstract][Full Text] [Related]
3. Unsteady non-Newtonian blood flow through a tapered overlapping stenosed catheterized vessel.
Ali N; Zaman A; Sajid M; Nieto JJ; Torres A
Math Biosci; 2015 Nov; 269():94-103. PubMed ID: 26361287
[TBL] [Abstract][Full Text] [Related]
4. Finite element computation of magneto-hemodynamic flow and heat transfer in a bifurcated artery with saccular aneurysm using the Carreau-Yasuda biorheological model.
Dubey A; B V; Bég OA; Gorla RSR
Microvasc Res; 2021 Nov; 138():104221. PubMed ID: 34271062
[TBL] [Abstract][Full Text] [Related]
5. Pulsatile magneto-hydrodynamic blood flows through porous blood vessels using a third grade non-Newtonian fluids model.
Akbarzadeh P
Comput Methods Programs Biomed; 2016 Apr; 126():3-19. PubMed ID: 26792174
[TBL] [Abstract][Full Text] [Related]
6. Effects of porosity in four-layered non-linear blood rheology in constricted narrow arteries with clinical applications.
Wajihah S A; Sankar DS
Comput Methods Programs Biomed; 2021 Feb; 199():105907. PubMed ID: 33412286
[TBL] [Abstract][Full Text] [Related]
7. Numerical investigation of unsteady pulsatile Newtonian/non-Newtonian blood flow through curved stenosed arteries.
Lakzian E; Akbarzadeh P
Biomed Mater Eng; 2020; 30(5-6):525-540. PubMed ID: 31771034
[TBL] [Abstract][Full Text] [Related]
8. Numerical simulation of the transport of nanoparticles as drug carriers in hydromagnetic blood flow through a diseased artery with vessel wall permeability and rheological effects.
Tripathi J; Vasu B; Bég OA; Mounika BR; Gorla RSR
Microvasc Res; 2022 Jan; 139():104241. PubMed ID: 34508788
[TBL] [Abstract][Full Text] [Related]
9. Pulsatile flow of thixotropic blood in artery under external body acceleration.
Cheffar L; Benslimane A; Sadaoui D; Benchabane A; Bekkour K
Comput Methods Biomech Biomed Engin; 2023 Jun; 26(8):927-940. PubMed ID: 35852069
[TBL] [Abstract][Full Text] [Related]
10. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.
Abdollahzadeh Jamalabadi MY; Akbari Bidokhti AA; Khak Rah H; Vaezi S; Hooshmand P
PLoS One; 2016; 11(12):e0167393. PubMed ID: 27941986
[TBL] [Abstract][Full Text] [Related]
11. Computational simulation of rheological blood flow containing hybrid nanoparticles in an inclined catheterized artery with stenotic, aneurysmal and slip effects.
Tripathi J; Vasu B; Bég OA; Gorla RSR; Kameswaran PK
Comput Biol Med; 2021 Dec; 139():105009. PubMed ID: 34775156
[TBL] [Abstract][Full Text] [Related]
12. Computational fluid dynamic simulation of two-fluid non-Newtonian nanohemodynamics through a diseased artery with a stenosis and aneurysm.
Dubey A; Vasu B; Anwar Bég O; Gorla RSR; Kadir A
Comput Methods Biomech Biomed Engin; 2020 Jun; 23(8):345-371. PubMed ID: 32098508
[TBL] [Abstract][Full Text] [Related]
13. Simulations of Magnetohemodynamics in Stenosed Arteries in Diabetic or Anemic Models.
Alshare A; Tashtoush B
Comput Math Methods Med; 2016; 2016():8123930. PubMed ID: 27057205
[TBL] [Abstract][Full Text] [Related]
14. Investigation of the plaque morphology effect on changes of pulsatile blood flow in a stenosed curved artery induced by an external magnetic field.
Teimouri K; Tavakoli MR; Ghafari A; Kim KC
Comput Biol Med; 2021 Aug; 135():104600. PubMed ID: 34214938
[TBL] [Abstract][Full Text] [Related]
15. Significance of Hall currents on hybrid nano-blood flow through an inclined artery having mild stenosis: Homotopy perturbation approach.
Das S; Pal TK; Jana RN; Giri B
Microvasc Res; 2021 Sep; 137():104192. PubMed ID: 34081994
[TBL] [Abstract][Full Text] [Related]
16. Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation.
Vasu B; Dubey A; Bég OA; Gorla RSR
Comput Biol Med; 2020 Nov; 126():104025. PubMed ID: 33074112
[TBL] [Abstract][Full Text] [Related]
17. Coronary arteries hemodynamics: effect of arterial geometry on hemodynamic parameters causing atherosclerosis.
Wong KKL; Wu J; Liu G; Huang W; Ghista DN
Med Biol Eng Comput; 2020 Aug; 58(8):1831-1843. PubMed ID: 32519006
[TBL] [Abstract][Full Text] [Related]
18. Pulsatile flow of non-Newtonian blood fluid inside stenosed arteries: Investigating the effects of viscoelastic and elastic walls, arteriosclerosis, and polycythemia diseases.
Nejad AA; Talebi Z; Cheraghali D; Shahbani-Zahiri A; Norouzi M
Comput Methods Programs Biomed; 2018 Feb; 154():109-122. PubMed ID: 29249336
[TBL] [Abstract][Full Text] [Related]
19. Numerical simulation of unsteady micropolar hemodynamics in a tapered catheterized artery with a combination of stenosis and aneurysm.
Zaman A; Ali N; Anwar Bég O
Med Biol Eng Comput; 2016 Sep; 54(9):1423-36. PubMed ID: 26541601
[TBL] [Abstract][Full Text] [Related]
20. Computational modeling of non-Newtonian blood flow through stenosed arteries in the presence of magnetic field.
Alshare A; Tashtoush B; El-Khalil HH
J Biomech Eng; 2013 Nov; 135(11):114503. PubMed ID: 24061603
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]