These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 37478794)

  • 1. Motor unit number estimation by MScanFit in myotonic dystrophies.
    Schneider C; Svačina MKR; Kohle F; Sprenger-Svačina A; Fink GR; Lehmann HC
    J Neurol Sci; 2023 Aug; 451():120728. PubMed ID: 37478794
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimating motor unit numbers from a CMAP scan: Repeatability study on three muscles at 15 centres.
    Sørensen DM; Bostock H; Abrahao A; Alaamel A; Alaydin HC; Ballegaard M; Boran E; Cengiz B; de Carvalho M; Dunker Ø; Fuglsang-Frederiksen A; Graffe CC; Jones KE; Kallio M; Kalra S; Krarup C; Krøigård T; Liguori R; Lupescu T; Maitland S; Matamala JM; Moldovan M; Moreno-Roco J; Nilsen KB; Phung L; Santos MO; Themistocleous AC; Uysal H; Vacchiano V; Whittaker RG; Zinman L; Tankisi H
    Clin Neurophysiol; 2023 Jul; 151():92-99. PubMed ID: 37236129
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility and reliability of MScanFit motor unit number estimation in peroneus longus muscle.
    Tankisi DA; Alaydin HC; Boran E; Cengiz B
    Muscle Nerve; 2022 Oct; 66(4):503-507. PubMed ID: 35763284
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Motor unit number estimation via MScanFit MUNE in spinal muscular atrophy.
    Vacchiano V; Morabito F; Faini C; Nocera G; Not R; Scarpini G; Romagnoli M; Pini A; Liguori R
    Muscle Nerve; 2024 Jul; 70(1):71-81. PubMed ID: 38549445
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimation of the number of motor units in the human extensor digitorum brevis using MScanFit.
    Klein CS; Liu H; Xiong Y
    PLoS One; 2024; 19(4):e0302214. PubMed ID: 38669263
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reproducibility of motor unit number index and MScanFit motor unit number estimation across intrinsic hand muscles.
    Higashihara M; Menon P; van den Bos M; Pavey N; Vucic S
    Muscle Nerve; 2020 Aug; 62(2):192-200. PubMed ID: 32077117
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessing inter-rater reproducibility in MScanFit MUNE in a 6-subject, 12-rater "Round Robin" setup.
    Sørensen DM; Bostock H; Ballegaard M; Fuglsang-Frederiksen A; Graffe CC; Grötting A; Jones K; Kallio M; Krarup C; Krøigård T; Lupescu T; Maitland S; Moldovan M; Nilsen KB; Pugdahl K; Santos MO; Themistocleous AC; Zlateva SS; Ööpik M; Tankisi H
    Neurophysiol Clin; 2022 Apr; 52(2):157-169. PubMed ID: 34906430
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The utility of motor unit number estimation methods versus quantitative motor unit potential analysis in diagnosis of ALS.
    Jacobsen AB; Kristensen RS; Witt A; Kristensen AG; Duez L; Beniczky S; Fuglsang-Frederiksen A; Tankisi H
    Clin Neurophysiol; 2018 Mar; 129(3):646-653. PubMed ID: 29414408
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic detection of F waves and F-MUNE in two types of motor neuron diseases.
    Oguz-Akarsu E; Sirin NG; Artug T; Erbas B; Kocasoy Orhan E; Idrisoğlu HA; Ketenci A; Baslo MB; Oge AE
    Muscle Nerve; 2022 Apr; 65(4):422-432. PubMed ID: 35020950
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Following disease progression in motor neuron disorders with 3 motor unit number estimation methods.
    Jacobsen AB; Bostock H; Tankisi H
    Muscle Nerve; 2019 Jan; 59(1):82-87. PubMed ID: 30025164
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of surface electrode recording area on compound muscle action potential scan processing for motor unit number estimation.
    Zhang D; Lu Z; Gong W; Zhou P
    Front Neurosci; 2024; 18():1382871. PubMed ID: 38841095
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of early motor involvement in diabetic polyneuropathy using a novel MUNE method - MScanFit MUNE.
    Kristensen AG; Bostock H; Finnerup NB; Andersen H; Jensen TS; Gylfadottir S; Itani M; Krøigård T; Sindrup S; Tankisi H
    Clin Neurophysiol; 2019 Oct; 130(10):1981-1987. PubMed ID: 31476704
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MScanFit motor unit number estimation of abductor pollicis brevis: Findings from different experimental parameters.
    Zong Y; Lu Z; Xu P; Chen M; Deng L; Li S; Zhang Y; Xie Q; Zhou P
    Front Aging Neurosci; 2022; 14():953173. PubMed ID: 36325193
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Subclinical motor involvement in nonsystemic vasculitic neuropathy determined by the motor unit number estimation method MScanFit.
    Schneider C; Wassermann MK; Svačina MKR; Wunderlich G; Fink GR; Lehmann HC
    Muscle Nerve; 2023 Jun; 67(6):474-480. PubMed ID: 36905193
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimating the motor unit number of the flexor carpi ulnaris muscle with MScanFit MUNE.
    Alaydin HC; Turkmen N; Boran HE; Cengiz B
    Muscle Nerve; 2022 Aug; 66(2):212-215. PubMed ID: 35621353
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Motor unit number estimation of human abductor hallucis from a compound muscle action potential scan.
    Li X; Zong Y; Klein CS; Zhou P
    Muscle Nerve; 2018 Nov; 58(5):735-737. PubMed ID: 29981247
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MScanFit motor unit number estimation of human anconeus muscle.
    Zong Y; Lu Z; Chen M; Xie Q; Zhou P
    Muscle Nerve; 2022 Apr; 65(4):460-463. PubMed ID: 34993997
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative assessment of MScanFit MUNE and quantitative EMG in amyotrophic lateral sclerosis diagnosis: A prospective study.
    Vacchiano V; Di Stasi V; Teodorani L; Faini C; Morabito F; Liguori R
    Clin Neurophysiol; 2024 Oct; 166():66-73. PubMed ID: 39126873
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reproducibility, and sensitivity to motor unit loss in amyotrophic lateral sclerosis, of a novel MUNE method: MScanFit MUNE.
    Jacobsen AB; Bostock H; Fuglsang-Frederiksen A; Duez L; Beniczky S; Møller AT; Blicher JU; Tankisi H
    Clin Neurophysiol; 2017 Jul; 128(7):1380-1388. PubMed ID: 28461135
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MScanFit motor unit number estimation and muscle velocity recovery cycle recordings in diabetic polyneuropathy.
    Kristensen AG; Khan KS; Bostock H; Khan BS; Gylfadottir S; Andersen H; Finnerup NB; Jensen TS; Tankisi H
    Clin Neurophysiol; 2020 Nov; 131(11):2591-2599. PubMed ID: 32927215
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.