136 related articles for article (PubMed ID: 37504970)
1. Poly(2-ethyl-2-oxazoline)-Conjugated Hemoglobins as a Red Blood Cell Substitute.
Okamoto W; Hiwatashi Y; Kobayashi T; Morita Y; Onozawa H; Iwazaki M; Kohno M; Tomiyasu H; Tochinai R; Georgieva R; Bäumler H; Komatsu T
ACS Appl Bio Mater; 2023 Aug; 6(8):3330-3340. PubMed ID: 37504970
[TBL] [Abstract][Full Text] [Related]
2. Polyoxazoline-conjugated porcine serum albumin as an artificial plasma expander for dogs.
Okamoto W; Usui T; Hasegawa M; Kobayashi T; Fujisawa J; Taguchi K; Matsumoto K; Kohno M; Iwazaki M; Shimano S; Nagao I; Toyoda H; Matsumura N; Tomiyasu H; Tochinai R; Komatsu T
Sci Rep; 2023 Jun; 13(1):9512. PubMed ID: 37316550
[TBL] [Abstract][Full Text] [Related]
3. Hemoglobin-albumin clusters as an artificial O
Okamoto W; Hasegawa M; Usui T; Kashima T; Sakata S; Hamano T; Onozawa H; Hashimoto R; Iwazaki M; Kohno M; Komatsu T
J Biomed Mater Res B Appl Biomater; 2022 Aug; 110(8):1827-1838. PubMed ID: 35191606
[TBL] [Abstract][Full Text] [Related]
4. Core-Shell Structured Hemoglobin Nanoparticles as Artificial O
Okamoto W; Hasegawa M; Kohyama N; Kobayashi T; Usui T; Onozawa H; Hashimoto R; Iwazaki M; Kohno M; Georgieva R; Bäumler H; Komatsu T
ACS Appl Bio Mater; 2022 Dec; 5(12):5844-5853. PubMed ID: 36399036
[TBL] [Abstract][Full Text] [Related]
5. Influence of Molecular Structure on O2-Binding Properties and Blood Circulation of Hemoglobin‒Albumin Clusters.
Yamada K; Yokomaku K; Haruki R; Taguchi K; Nagao S; Maruyama T; Otagiri M; Komatsu T
PLoS One; 2016; 11(2):e0149526. PubMed ID: 26895315
[TBL] [Abstract][Full Text] [Related]
6. Artificial Blood for Dogs.
Yamada K; Yokomaku K; Kureishi M; Akiyama M; Kihira K; Komatsu T
Sci Rep; 2016 Nov; 6():36782. PubMed ID: 27830776
[TBL] [Abstract][Full Text] [Related]
7. Safety Evaluation of Hemoglobin-Albumin Cluster "HemoAct" as a Red Blood Cell Substitute.
Haruki R; Kimura T; Iwasaki H; Yamada K; Kamiyama I; Kohno M; Taguchi K; Nagao S; Maruyama T; Otagiri M; Komatsu T
Sci Rep; 2015 Jul; 5():12778. PubMed ID: 26220366
[TBL] [Abstract][Full Text] [Related]
8. Synthesis and physicochemical characterization of a series of hemoglobin-based oxygen carriers: objective comparison between cellular and acellular types.
Sakai H; Yuasa M; Onuma H; Takeoka S; Tsuchida E
Bioconjug Chem; 2000; 11(1):56-64. PubMed ID: 10639086
[TBL] [Abstract][Full Text] [Related]
9. Isovolemic exchange transfusion with increasing concentrations of low oxygen affinity hemoglobin solution limits oxygen delivery due to vasoconstriction.
Cabrales P; Tsai AG; Intaglietta M
Am J Physiol Heart Circ Physiol; 2008 Nov; 295(5):H2212-8. PubMed ID: 18835914
[TBL] [Abstract][Full Text] [Related]
10. Hemoglobin-albumin cluster: physiological responses after exchange transfusion into rats and blood circulation persistence in dogs.
Iwasaki H; Yokomaku K; Kureishi M; Igarashi K; Hashimoto R; Kohno M; Iwazaki M; Haruki R; Akiyama M; Asai K; Nakamura Y; Funaki R; Morita Y; Komatsu T
Artif Cells Nanomed Biotechnol; 2018; 46(sup3):S621-S629. PubMed ID: 30585092
[TBL] [Abstract][Full Text] [Related]
11. A novel hemoglobin-adenosine-glutathione based blood substitute: evaluation of its effects on human blood ex vivo.
Simoni J; Simoni G; Wesson DE; Griswold JA; Feola M
ASAIO J; 2000; 46(6):679-92. PubMed ID: 11110264
[TBL] [Abstract][Full Text] [Related]
12. ZIF-8 metal organic framework nanoparticle loaded with tense quaternary state polymerized bovine hemoglobin: potential red blood cell substitute with antioxidant properties.
Gu X; Allyn M; Swindle-Reilly K; Palmer AF
Nanoscale; 2023 May; 15(19):8832-8844. PubMed ID: 37114464
[TBL] [Abstract][Full Text] [Related]
13. Analysis of polyethylene-glycol-polylactide nano-dimension artificial red blood cells in maintaining systemic hemoglobin levels and prevention of methemoglobin formation.
Chang TM; Powanda D; Yu WP
Artif Cells Blood Substit Immobil Biotechnol; 2003 Aug; 31(3):231-47. PubMed ID: 12906306
[TBL] [Abstract][Full Text] [Related]
14. Diaspirin crosslinked hemoglobin improves systemic oxygen uptake in oxygen supply-dependent septic rats.
Sielenkämper AW; Chin-Yee IH; Martin CM; Sibbald WJ
Am J Respir Crit Care Med; 1997 Oct; 156(4 Pt 1):1066-72. PubMed ID: 9351604
[TBL] [Abstract][Full Text] [Related]
15. Resuscitation with polyethylene glycol-modified human hemoglobin improves microcirculatory blood flow and tissue oxygenation after hemorrhagic shock in awake hamsters.
Wettstein R; Tsai AG; Erni D; Winslow RM; Intaglietta M
Crit Care Med; 2003 Jun; 31(6):1824-30. PubMed ID: 12794426
[TBL] [Abstract][Full Text] [Related]
16. Recent and prominent examples of nano- and microarchitectures as hemoglobin-based oxygen carriers.
Jansman MMT; Hosta-Rigau L
Adv Colloid Interface Sci; 2018 Oct; 260():65-84. PubMed ID: 30177214
[TBL] [Abstract][Full Text] [Related]
17. Safety profile of high molecular weight polymerized hemoglobins.
Muller CR; Williams AT; Munoz CJ; Eaker AM; Breton AN; Palmer AF; Cabrales P
Transfusion; 2021 Jan; 61(1):212-224. PubMed ID: 33104250
[TBL] [Abstract][Full Text] [Related]
18. Hemoglobin vesicles and red blood cells as carriers of carbon monoxide prior to oxygen for resuscitation after hemorrhagic shock in a rat model.
Sakai H; Horinouchi H; Tsuchida E; Kobayashi K
Shock; 2009 May; 31(5):507-14. PubMed ID: 18827742
[TBL] [Abstract][Full Text] [Related]
19. Red cell substitutes from hemoglobin--do we start all over again?
Kluger R
Curr Opin Chem Biol; 2010 Aug; 14(4):538-43. PubMed ID: 20392662
[TBL] [Abstract][Full Text] [Related]
20. Development of novel oxygen carriers by coupling hemoglobin to functionalized multiwall carbon nanotubes.
Zhang K; Xiao X; Li L; Fan Y; Cai Q; Lee IS; Li X
J Mater Chem B; 2019 Aug; 7(31):4821-4832. PubMed ID: 31389959
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]