BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 37506454)

  • 1. Diffuse transmittance visible spectroscopy using smartphone flashlight for photoplethysmography and vital signs measurements.
    Bachir W
    Spectrochim Acta A Mol Biomol Spectrosc; 2023 Dec; 303():123181. PubMed ID: 37506454
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo Analysis of Optical Interactions in Reflectance and Transmittance Finger Photoplethysmography.
    Chatterjee S; Kyriacou PA
    Sensors (Basel); 2019 Feb; 19(4):. PubMed ID: 30769957
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.
    Abay TY; Kyriacou PA
    J Clin Monit Comput; 2018 Jun; 32(3):447-455. PubMed ID: 28547651
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring of Heart Rate from Photoplethysmographic Signals Using a Samsung Galaxy Note8 in Underwater Environments.
    Askarian B; Jung K; Chong JW
    Sensors (Basel); 2019 Jun; 19(13):. PubMed ID: 31248022
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A motion-tolerant approach for monitoring SpO
    Fan F; Yan Y; Tang Y; Zhang H
    Comput Biol Med; 2017 Dec; 91():291-305. PubMed ID: 29102826
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Resting and Postexercise Heart Rate Detection From Fingertip and Facial Photoplethysmography Using a Smartphone Camera: A Validation Study.
    Yan BP; Chan CK; Li CK; To OT; Lai WH; Tse G; Poh YC; Poh MZ
    JMIR Mhealth Uhealth; 2017 Mar; 5(3):e33. PubMed ID: 28288955
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.
    Shafique M; Kyriacou PA; Pal SK
    Med Biol Eng Comput; 2012 Jun; 50(6):575-83. PubMed ID: 22555629
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Signal quality measures for pulse oximetry through waveform morphology analysis.
    Sukor JA; Redmond SJ; Lovell NH
    Physiol Meas; 2011 Mar; 32(3):369-84. PubMed ID: 21330696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation.
    Gruwez H; Ezzat D; Van Puyvelde T; Dhont S; Meekers E; Bruckers L; Wouters F; Kellens M; Van Herendael H; Rivero-Ayerza M; Nuyens D; Haemers P; Pison L
    Europace; 2024 Mar; 26(4):. PubMed ID: 38630867
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Smartphone Biosensor With App Meets FDA/ISO Standards for Clinical Pulse Oximetry and Can Be Reliably Used by a Wide Range of Patients.
    Browne SH; Bernstein M; Pan SC; Gonzalez Garcia J; Easson CA; Huang CC; Vaida F
    Chest; 2021 Feb; 159(2):724-732. PubMed ID: 32926871
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System.
    Shao D; Liu C; Tsow F; Yang Y; Du Z; Iriya R; Yu H; Tao N
    IEEE Trans Biomed Eng; 2016 Jun; 63(6):1091-8. PubMed ID: 26415199
    [TBL] [Abstract][Full Text] [Related]  

  • 13. PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities.
    Solé Morillo Á; Lambert Cause J; Baciu VE; da Silva B; Garcia-Naranjo JC; Stiens J
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214290
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enhancing the Robustness of Smartphone Photoplethysmography: A Signal Quality Index Approach.
    Liu I; Ni S; Peng K
    Sensors (Basel); 2020 Mar; 20(7):. PubMed ID: 32235543
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR).
    Bradke B; Everman B
    Biosensors (Basel); 2020 Apr; 10(4):. PubMed ID: 32260393
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An EEMD-PCA approach to extract heart rate, respiratory rate and respiratory activity from PPG signal.
    Motin MA; Karmakar CK; Palaniswami M
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3817-3820. PubMed ID: 28269118
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Heart Rate Extraction from Novel Neck Photoplethysmography Signals.
    Garcia-Lopez I; Sharma P; Rodriguez-Villegas E
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():6541-6544. PubMed ID: 31947340
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion.
    Abay TY; Kyriacou PA
    IEEE Trans Biomed Eng; 2015 Sep; 62(9):2187-95. PubMed ID: 25838515
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera.
    Bánhalmi A; Borbás J; Fidrich M; Bilicki V; Gingl Z; Rudas L
    J Healthc Eng; 2018; 2018():4038034. PubMed ID: 29666670
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Posture effects on the calibratability of remote pulse oximetry in visible light.
    Moço A; Stuijk S; de Haan G
    Physiol Meas; 2019 Apr; 40(3):035005. PubMed ID: 30731445
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.