153 related articles for article (PubMed ID: 37509399)
21. Dielectric properties for non-invasive detection of normal, benign, and malignant breast tissues using microwave theories.
Cheng Y; Fu M
Thorac Cancer; 2018 Apr; 9(4):459-465. PubMed ID: 29465782
[TBL] [Abstract][Full Text] [Related]
22. Computed Tomography-Based Modeling of Water Vapor-Induced Changes in Permittivity During Microwave Ablation.
Etoz S; Brace CL
IEEE Trans Biomed Eng; 2020 Sep; 67(9):2427-2433. PubMed ID: 31880538
[TBL] [Abstract][Full Text] [Related]
23. [Comparison of dielectric properties of normal human esophagus and esophageal cancer using an open-ended coaxial probe].
Huang Q; Lu D; Han J; Yu H; Dong W; Cai K; Yu X
Nan Fang Yi Ke Da Xue Xue Bao; 2021 Nov; 41(11):1741-1746. PubMed ID: 34916203
[TBL] [Abstract][Full Text] [Related]
24. A Pilot Study of the Impact of Microwave Ablation on the Dielectric Properties of Breast Tissue.
Neira LM; Mays RO; Sawicki JF; Schulman A; Harter J; Wilke LG; Behdad N; Van Veen BD; Hagness SC
Sensors (Basel); 2020 Oct; 20(19):. PubMed ID: 33036268
[TBL] [Abstract][Full Text] [Related]
25. A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries.
Lazebnik M; McCartney L; Popovic D; Watkins CB; Lindstrom MJ; Harter J; Sewall S; Magliocco A; Booske JH; Okoniewski M; Hagness SC
Phys Med Biol; 2007 May; 52(10):2637-56. PubMed ID: 17473342
[TBL] [Abstract][Full Text] [Related]
26. Dielectric properties of brain tissue between 0.01 and 10 GHz.
Foster KR; Schepps JL; Stoy RD; Schwan HP
Phys Med Biol; 1979 Nov; 24(6):1177-87. PubMed ID: 531093
[TBL] [Abstract][Full Text] [Related]
27. In Vivo Dielectric Properties of Healthy and Benign Rat Mammary Tissues from 500 MHz to 18 GHz.
Yilmaz T; Ates Alkan F
Sensors (Basel); 2020 Apr; 20(8):. PubMed ID: 32295215
[TBL] [Abstract][Full Text] [Related]
28. Complex Dielectric Permittivity Spectra of Rapeseed in the 20 MHz-3 GHz Frequency Range.
Kafarski M; Szypłowska A; Majcher J; Wilczek A; Lewandowski A; Hlaváčová Z; Skierucha W
Materials (Basel); 2022 Jul; 15(14):. PubMed ID: 35888310
[TBL] [Abstract][Full Text] [Related]
29. Breast cancer cells exhibits specific dielectric signature in vitro using the open-ended coaxial probe technique from 200 MHz to 13.6 GHz.
Hussein M; Awwad F; Jithin D; El Hasasna H; Athamneh K; Iratni R
Sci Rep; 2019 Mar; 9(1):4681. PubMed ID: 30886170
[TBL] [Abstract][Full Text] [Related]
30. Dielectric properties of muscle and liver from 500 MHz-40 GHz.
Abdilla L; Sammut C; Mangion LZ
Electromagn Biol Med; 2013 Jun; 32(2):244-52. PubMed ID: 23675628
[TBL] [Abstract][Full Text] [Related]
31. Dielectric spectroscopy of normal and malignant human lung cells at ultra-high frequencies.
Egot-Lemaire S; Pijanka J; Sulé-Suso J; Semenov S
Phys Med Biol; 2009 Apr; 54(8):2341-57. PubMed ID: 19321925
[TBL] [Abstract][Full Text] [Related]
32. Dielectric characterization of diseased human trabecular bones at microwave frequency.
Amin B; Shahzad A; Farina L; Parle E; McNamara L; O'Halloran M; Elahi MA
Med Eng Phys; 2020 Apr; 78():21-28. PubMed ID: 32037281
[TBL] [Abstract][Full Text] [Related]
33. Dielectric spectroscopy of Baijiu over 2-20 GHz using an open-ended coaxial probe.
Li Z; Haigh A; Wang P; Soutis C; Gibson A
J Food Sci; 2021 Jun; 86(6):2513-2524. PubMed ID: 33908622
[TBL] [Abstract][Full Text] [Related]
34. Experimental characterisation of the thermal lesion induced by microwave ablation.
Lopresto V; Pinto R; Cavagnaro M
Int J Hyperthermia; 2014 Mar; 30(2):110-8. PubMed ID: 24571174
[TBL] [Abstract][Full Text] [Related]
35. Effect of changes in lung physical properties on microwave ablation zone during respiration.
Yang D; Cao M
Biomed Eng Lett; 2020 May; 10(2):285-298. PubMed ID: 32477612
[TBL] [Abstract][Full Text] [Related]
36. Open-Ended Coaxial Probe Measurements of Complex Dielectric Permittivity in Diesel-Contaminated Soil during Bioremediation.
Vergnano A; Godio A; Raffa CM; Chiampo F; Tobon Vasquez JA; Vipiana F
Sensors (Basel); 2020 Nov; 20(22):. PubMed ID: 33266411
[TBL] [Abstract][Full Text] [Related]
37. The UHF and microwave dielectric properties of normal and tumour tissues: variation in dielectric properties with tissue water content.
Schepps JL; Foster KR
Phys Med Biol; 1980 Nov; 25(6):1149-59. PubMed ID: 7208627
[TBL] [Abstract][Full Text] [Related]
38. Design of a Sub-6 GHz Dielectric Resonator Antenna with Novel Temperature-Stabilized (Sm
Wu FF; Zhou D; Du C; Jin BB; Li C; Qi ZM; Sun S; Zhou T; Li Q; Zhang XQ
ACS Appl Mater Interfaces; 2022 Feb; 14(5):7030-7038. PubMed ID: 35084812
[TBL] [Abstract][Full Text] [Related]
39. Design analysis and validation of coaxial probe for tissue dielectric properties evaluation used in specific absorption rate measurement.
Naik BV
Electromagn Biol Med; 2022 Jan; 41(1):60-70. PubMed ID: 34856852
[TBL] [Abstract][Full Text] [Related]
40. Dielectric Permittivity Measurement Using Open-Ended Coaxial Probe-Modeling and Simulation Based on the Simple Capacitive-Load Model.
Šarolić A; Matković A
Sensors (Basel); 2022 Aug; 22(16):. PubMed ID: 36015790
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]