  • 1. Amperometric enzyme electrode system for extracorporeal lactate monitoring based on lactate dehydrogenase.
    Vadgama P; Covington AK; Alberti KG
    Analyst; 1986 Jul; 111(7):803-7. PubMed ID: 3752521
    [No Abstract]   [Full Text] [Related]  

  • 2. Flow injection analysis of L-lactate with enzyme amplification and amperometric detection.
    Asouzu MU; Nonidez WK; Ho MH
    Anal Chem; 1990 Apr; 62(7):708-12. PubMed ID: 2327587
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An O2-based enzyme electrode for whole blood lactate measurement under continuous flow conditions.
    Weaver MR; Vadgama PM
    Clin Chim Acta; 1986 Mar; 155(3):295-307. PubMed ID: 3708858
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enzyme electrodes as practical biosensors.
    Vadgama P
    J Med Eng Technol; 1981 Nov; 5(6):293-8. PubMed ID: 7035672
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lactate and pyruvate electrochemical biosensors for whole blood in extracorporeal experiments with an endocrine artificial pancreas.
    Mascini M; Mazzei F; Moscone D; Calabrese G; Benedetti MM
    Clin Chem; 1987 Apr; 33(4):591-3. PubMed ID: 3829396
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous Detection of Lactate Enantiomers Based on Diffusion-controlled Bioelectrocatalysis.
    Matsui Y; Kitazumi Y; Shirai O; Kano K
    Anal Sci; 2018 Oct; 34(10):1137-1142. PubMed ID: 29863033
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enzyme electrodes based on organic metals.
    Kulys JJ
    Biosensors; 1986; 2(1):3-13. PubMed ID: 3790176
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biosensor for lactate determination in biological fluids. I. Construction and properties of the biosensor.
    Racek J; Musil J
    Clin Chim Acta; 1987 Jan; 162(2):129-39. PubMed ID: 3549065
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bioluminescent flow sensor for the determination of L-(+)-lactate.
    Girotti S; Grigolo B; Ferri E; Ghini S; Carrea G; Bovara R; Roda A; Motta R; Petilino R
    Analyst; 1990 Jul; 115(7):889-94. PubMed ID: 2221397
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermostable amperometric lactate biosensor with Clostridium thermocellum L-LDH for the measurement of blood lactate.
    Ozkan M; Erhan E; Terzi O; Tan I; Ozöner SK
    Talanta; 2009 Oct; 79(5):1412-7. PubMed ID: 19635378
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A coupled enzymatic method to measure blood lactate by amperometric monitoring of the rate of oxygen depletion with a Clark oxygen electrode.
    Cheng FS; Christian GD
    Clin Chim Acta; 1979 Feb; 91(3):295-301. PubMed ID: 32977
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single- and coupled-enzyme nylon tube reactors for routine determination of pyruvate and lactate in serum.
    Sundaram PV; Hinsch W
    Clin Chem; 1979 Feb; 25(2):285-8. PubMed ID: 759022
    [TBL] [Abstract][Full Text] [Related]  

  • 13. "Wired" enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances.
    Ohara TJ; Rajagopalan R; Heller A
    Anal Chem; 1994 Aug; 66(15):2451-7. PubMed ID: 8092486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Polymeric FAD used as enzyme-friendly mediator in lactate detection.
    Leonida MD; Starczynowski DT; Waldman R; Aurian-Blajeni B
    Anal Bioanal Chem; 2003 Jul; 376(6):832-7. PubMed ID: 12811450
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An L-lactate sensor with immobilized enzyme for use in in vivo studies with an endocrine artificial pancreas.
    Mascini M; Fortunati S; Moscone D; Palleschi G; Massi-Benedetti M; Fabietti P
    Clin Chem; 1985 Mar; 31(3):451-3. PubMed ID: 3971566
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimal-Fouling enzyme electrode for continuous flow measurement of whole blood lactate.
    Kyröläinen M; Håkanson H; Mattiasson B; Vadgama P
    Biosens Bioelectron; 1997; 12(11):1073-81. PubMed ID: 9451796
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Amperometric L-lactate sensor based on sol-gel processing of an enzyme-linked silicon alkoxide.
    Lin CL; Shih CL; Chau LK
    Anal Chem; 2007 May; 79(10):3757-63. PubMed ID: 17417817
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spectrophotometric and electrochemical determinations of L(+)-lactate in blood by use of lactate dehydrogenase from yeast.
    Durliat H; Comtat M; Baudras A
    Clin Chem; 1976 Nov; 22(11):1802-5. PubMed ID: 975541
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Paramax triglycerides reagent: interference from high L-lactate and lactate dehydrogenase.
    Whinna HC; Krueger-Nielsen S; Uomoto J; Raisys V
    Clin Chem; 1996 May; 42(5):778. PubMed ID: 8653911
    [No Abstract]   [Full Text] [Related]  

  • 20. Determinations of lactate and lactate dehydrogenase activity in serum with the flow injection analysis system involving immobilized enzyme column and chemiluminescence.
    Tabata M; Totani M; Murachi T
    Anal Biochem; 1991 Feb; 193(1):112-7. PubMed ID: 2042735
    [TBL] [Abstract][Full Text] [Related]  