These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 37525742)
21. Eliminating projection error of measuring Pauwels' angle in the femur neck fractures by CT plane manipulation. Kong GM; Kwak JM; Jung GH Orthop Traumatol Surg Res; 2020 Jun; 106(4):607-611. PubMed ID: 31786132 [TBL] [Abstract][Full Text] [Related]
22. An update on the Pauwels classification. Shen M; Wang C; Chen H; Rui YF; Zhao S J Orthop Surg Res; 2016 Dec; 11(1):161. PubMed ID: 27955672 [TBL] [Abstract][Full Text] [Related]
23. Fracture morphology and biomechanical characteristics of Pauwels III femoral neck fractures in young adults. Wang K; Ni M; Liao P; Dou B; Yan X; Lv L; Zhang F; Mei J Injury; 2021 Nov; 52(11):3227-3238. PubMed ID: 34481668 [TBL] [Abstract][Full Text] [Related]
24. Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element. Fan Z; Chen P; Yu X; Li X; Su H; Chen H; Yang B; Qi J; Wang H BMC Musculoskelet Disord; 2023 Jan; 24(1):54. PubMed ID: 36681804 [TBL] [Abstract][Full Text] [Related]
25. What Is the Reliability and Accuracy of Intraoperative Fluoroscopy in Evaluating Anterior, Lateral, and Posterior Coverage During Periacetabular Osteotomy? Wylie JD; Ferrer MG; McClincy MP; Miller PE; Millis MB; Kim YJ; Novais EN Clin Orthop Relat Res; 2019 May; 477(5):1138-1144. PubMed ID: 30676406 [TBL] [Abstract][Full Text] [Related]
26. [Characteristics of femoral neck fractures in young and middle-aged adults based on fracture mapping technology]. Wang Y; Xu Z; Li P; Zhang Y; Su Z; Ni M Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Sep; 36(9):1078-1083. PubMed ID: 36111468 [TBL] [Abstract][Full Text] [Related]
27. Classification and treatment of proximal humerus fractures: inter-observer reliability and agreement across imaging modalities and experience. Foroohar A; Tosti R; Richmond JM; Gaughan JP; Ilyas AM J Orthop Surg Res; 2011 Jul; 6():38. PubMed ID: 21801370 [TBL] [Abstract][Full Text] [Related]
28. Evaluation of Gartland Classification, Baumann Angle and Anterior Humeral Line in Paediatrics Supracondylar Fractures: An Inter and Intra-Observer Reliability Study. Calogero V; Aulisa AG; Careri S; Masci G; Mastantuoni G; Falciglia F; Toniolo RM J Clin Med; 2023 Dec; 13(1):. PubMed ID: 38202175 [TBL] [Abstract][Full Text] [Related]
29. Inter-Observer and Intra-Observer Reliability of 2D Radiograph-Based Valgus Cut Angle Measurement in Preoperative Planning for Primary Total Knee Arthroplasty. Gopurathingal AA; Bhonsle S Cureus; 2021 Jan; 13(1):e12788. PubMed ID: 33628658 [TBL] [Abstract][Full Text] [Related]
30. Intra- and inter-observer reliability of measurements on 3D images of the calcaneus bone. Misselyn D; Caeyman A; Hoekstra H; Nijs S; Matricali G Comput Methods Biomech Biomed Engin; 2021 Apr; 24(5):579-583. PubMed ID: 33118845 [TBL] [Abstract][Full Text] [Related]
31. Reliability and clinical importance of teardrop angle measurement in intra-articular distal radius fracture. Fujitani R; Omokawa S; Iida A; Santo S; Tanaka Y J Hand Surg Am; 2012 Mar; 37(3):454-9. PubMed ID: 22284748 [TBL] [Abstract][Full Text] [Related]
32. Modified dynamic hip screw loaded with autologous bone graft for treating Pauwels type-3 vertical femoral neck fractures. Luo D; Zou W; He Y; Xian H; Wang L; Shen J; Lian K; Lin D Injury; 2017 Jul; 48(7):1579-1583. PubMed ID: 28583419 [TBL] [Abstract][Full Text] [Related]
33. [Study on biomechanical stability in simulated femoral neck fracture fixation by two cannulated screws]. He XJ; Xu HW; Ji K; Zhang ZW; Yan SG Zhongguo Gu Shang; 2016 Nov; 29(11):994-1000. PubMed ID: 29292634 [TBL] [Abstract][Full Text] [Related]
34. Medial femoral plate with cannulated screw for Pauwels type III femoral neck fracture: A meta-analysis. Su Z; Liang L; Hao Y J Back Musculoskelet Rehabil; 2021; 34(2):169-177. PubMed ID: 33164925 [TBL] [Abstract][Full Text] [Related]
35. Validation of two methods to measure posterior tilt in femoral neck fractures. Kalsbeek JH; van Walsum ADP; Roerdink WH; van Vugt AB; van de Krol H; Schipper IB Injury; 2020 Feb; 51(2):380-383. PubMed ID: 31839425 [TBL] [Abstract][Full Text] [Related]
36. Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis. Wang J; Gao Y; Song D; Ni J Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2022 Aug; 47(8):1143-1153. PubMed ID: 36097783 [TBL] [Abstract][Full Text] [Related]
37. Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis. Fan X; Zhou Y; Dai S; Lao K; Zhang Q; Yu T BMC Musculoskelet Disord; 2024 Jan; 25(1):83. PubMed ID: 38245678 [TBL] [Abstract][Full Text] [Related]
38. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study. Zhou L; Lin J; Huang A; Gan W; Zhai X; Sun K; Huang S; Li Z Clin Biomech (Bristol); 2020 Apr; 74():103-110. PubMed ID: 32155446 [TBL] [Abstract][Full Text] [Related]
39. Medialization of the Hip's Center with Periacetabular Osteotomy: Validation of Assessment with Plain Radiographs. Fowler LM; Nepple JJ; Devries C; Harris MD; Clohisy JC Clin Orthop Relat Res; 2021 May; 479(5):1040-1049. PubMed ID: 33861214 [TBL] [Abstract][Full Text] [Related]
40. Reliability of the Garden Alignment Index and Valgus Tilt Measurement for Nondisplaced Femoral Neck Fractures. Yamakawa Y; Yamamoto N; Tomita Y; Okuda R; Masada Y; Shiroshita A; Matsumoto T J Pers Med; 2022 Dec; 13(1):. PubMed ID: 36675714 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]