These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 37526221)

  • 41. Measurement of serum total vitamin D (25-OH) using automated immunoassay in comparison [corrected] with liquid chromatography tandem-mass spectrometry.
    Shin SY; Kwon MJ; Song J; Park H; Woo HY
    J Clin Lab Anal; 2013 Jul; 27(4):284-9. PubMed ID: 23852785
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Four automated 25-OH total vitamin D immunoassays and commercial liquid chromatography tandem-mass spectrometry in Finnish population.
    Koivula MK; Matinlassi N; Laitinen P; Risteli J
    Clin Lab; 2013; 59(3-4):397-405. PubMed ID: 23724631
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Performance characteristics of the VIDAS® 25-OH Vitamin D Total assay - comparison with four immunoassays and two liquid chromatography-tandem mass spectrometry methods in a multicentric study.
    Moreau E; Bächer S; Mery S; Le Goff C; Piga N; Vogeser M; Hausmann M; Cavalier E
    Clin Chem Lab Med; 2016 Jan; 54(1):45-53. PubMed ID: 26124054
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Evaluation of the new restandardized Abbott Architect 25-OH Vitamin D assay in vitamin D-insufficient and vitamin D-supplemented individuals.
    Annema W; Nowak A; von Eckardstein A; Saleh L
    J Clin Lab Anal; 2018 May; 32(4):e22328. PubMed ID: 28926129
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Improved Recognition of 25-Hydroxyvitamin D2 by 2 Automated Immunoassays.
    Geno KA; Tolan NV; Singh RJ; Nerenz RD
    J Appl Lab Med; 2020 Nov; 5(6):1287-1295. PubMed ID: 32529210
    [TBL] [Abstract][Full Text] [Related]  

  • 46. 25-Hydroxyvitamin D assays: Potential interference from other circulating vitamin D metabolites.
    Carter GD; Jones JC; Shannon J; Williams EL; Jones G; Kaufmann M; Sempos C
    J Steroid Biochem Mol Biol; 2016 Nov; 164():134-138. PubMed ID: 26718874
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Application of a new vitamin D blood test on the Emirati population.
    Shah I; Al-Dabbagh B; Gariballa S; Al-Menhali A; Muhammad N; Yasin J; Ashraf SS
    J Steroid Biochem Mol Biol; 2018 Jun; 180():118-128. PubMed ID: 29432962
    [TBL] [Abstract][Full Text] [Related]  

  • 48. 2-fluoro-1-methylpyridinium p-toluene sulfonate: a new LC-MS/MS derivatization reagent for vitamin D metabolites.
    Alexandridou A; Volmer DA
    J Lipid Res; 2023 Aug; 64(8):100409. PubMed ID: 37406930
    [TBL] [Abstract][Full Text] [Related]  

  • 49. National Estimates of Serum Total 25-Hydroxyvitamin D and Metabolite Concentrations Measured by Liquid Chromatography-Tandem Mass Spectrometry in the US Population during 2007-2010.
    Schleicher RL; Sternberg MR; Looker AC; Yetley EA; Lacher DA; Sempos CT; Taylor CL; Durazo-Arvizu RA; Maw KL; Chaudhary-Webb M; Johnson CL; Pfeiffer CM
    J Nutr; 2016 May; 146(5):1051-61. PubMed ID: 27052537
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry--a method comparison and validation.
    Bruce SJ; Rochat B; Béguin A; Pesse B; Guessous I; Boulat O; Henry H
    Rapid Commun Mass Spectrom; 2013 Jan; 27(1):200-6. PubMed ID: 23239334
    [TBL] [Abstract][Full Text] [Related]  

  • 51. 25-hydroxyvitamin D is a predictor of COVID-19 severity of hospitalized patients.
    Nguyen NN; Raju MNP; da Graca B; Wang D; Mohamed NA; Mutnal MB; Rao A; Bennett M; Gokingco M; Pham H; Mohammad AA
    PLoS One; 2022; 17(5):e0268038. PubMed ID: 35503795
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparison of four current 25-hydroxyvitamin D assays.
    Moon HW; Cho JH; Hur M; Song J; Oh GY; Park CM; Yun YM; Kim JQ
    Clin Biochem; 2012 Mar; 45(4-5):326-30. PubMed ID: 22244986
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A Comparison between Three Different Automated Total 25-hydroxyvitamin D Immunoassay Methods and Ultra Performance Liquid Chromatography.
    Reda H; Soliman S; Girguis H; Nagy M; Mahmoud Y; Yasser N
    Asian Pac J Cancer Prev; 2020 Apr; 21(4):1039-1044. PubMed ID: 32334467
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D₃ and 25-hydroxyvitamin D₂ using isotope-dilution liquid chromatography-tandem mass spectrometry.
    Mineva EM; Schleicher RL; Chaudhary-Webb M; Maw KL; Botelho JC; Vesper HW; Pfeiffer CM
    Anal Bioanal Chem; 2015 Jul; 407(19):5615-24. PubMed ID: 25967149
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method.
    Chen H; McCoy LF; Schleicher RL; Pfeiffer CM
    Clin Chim Acta; 2008 May; 391(1-2):6-12. PubMed ID: 18279671
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of automated 25-OH vitamin D immunoassays with liquid chromatography isotope dilution tandem mass spectrometry.
    Koivula MK; Turpeinen U; Laitinen P; Risteli J
    Clin Lab; 2012; 58(11-12):1253-61. PubMed ID: 23289196
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE).
    Thibeault D; Caron N; Djiana R; Kremer R; Blank D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():120-7. PubMed ID: 22265352
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A method to correct for the influence of bovine serum albumin-associated vitamin D metabolites in protein extracts from neonatal dried blood spots.
    Boelt SG; Plana-Ripoll O; Albiñana C; Vilhjálmsson B; McGrath JJ; Cohen AS
    BMC Res Notes; 2022 Jun; 15(1):194. PubMed ID: 35659347
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference.
    Roth HJ; Schmidt-Gayk H; Weber H; Niederau C
    Ann Clin Biochem; 2008 Mar; 45(Pt 2):153-9. PubMed ID: 18325178
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of two 25-hydroxyvitamin D immunoassays to liquid chromatography-tandem mass spectrometry in assessing samples from the Chinese population.
    Yun C; Chen J; Yang C; Li Y; Piao J; Yang X
    Clin Chim Acta; 2015 Aug; 448():22-6. PubMed ID: 26093339
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.