179 related articles for article (PubMed ID: 37535396)

  • 1. Comparison of setup accuracy of optical surface image versus orthogonal x-ray images for VMAT of the left breast using deep-inspiration breath-hold.
    Lu W; Hong LX; Yamada N; Berry SL; Song Y; Choi W; Cerviño LI; Tang X; Mechalakos JG; Romesser PB; Powell S; Li G
    J Appl Clin Med Phys; 2023 Dec; 24(12):e14117. PubMed ID: 37535396
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A uniform and versatile surface-guided radiotherapy procedure and workflow for high-quality breast deep-inspiration breath-hold treatment in a multi-center institution.
    Li G; Lu W; O'Grady K; Yan I; Yorke E; Arriba LIC; Powell S; Hong L
    J Appl Clin Med Phys; 2022 Mar; 23(3):e13511. PubMed ID: 35049108
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility study of deep inspiration breath-hold based volumetric modulated arc therapy for locally advanced left sided breast cancer patients.
    Swamy ST; Radha CA; Kathirvel M; Arun G; Subramanian S
    Asian Pac J Cancer Prev; 2014; 15(20):9033-8. PubMed ID: 25374248
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intrafraction tumor motion during deep inspiration breath hold pancreatic cancer treatment.
    Zeng C; Xiong W; Li X; Reyngold M; Gewanter RM; Cuaron JJ; Yorke ED; Li T
    J Appl Clin Med Phys; 2019 May; 20(5):37-43. PubMed ID: 30933428
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stereoscopic X-ray image and thermo-optical surface guidance for breast cancer radiotherapy in deep inspiration breath-hold.
    Buschmann M; Kauer-Dorner D; Konrad S; Georg D; Widder J; Knäusl B
    Strahlenther Onkol; 2024 Apr; 200(4):306-313. PubMed ID: 37796341
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of surface-guided patient setup for conventional radiotherapy of brain and nasopharynx cancer.
    Lee SK; Huang S; Zhang L; Ballangrud AM; Aristophanous M; Cervino Arriba LI; Li G
    J Appl Clin Med Phys; 2021 May; 22(5):48-57. PubMed ID: 33792186
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Residual setup errors in cranial stereotactic radiosurgery without six degree of freedom robotic couch: Frameless versus rigid immobilization systems.
    Liu RJ; Yang SX; Neylon J; Hall MD; Dandapani S; Vora N; Wong JYC; Liu A
    J Appl Clin Med Phys; 2020 Mar; 21(3):87-93. PubMed ID: 32068342
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy evaluation of a 3-dimensional surface imaging system for guidance in deep-inspiration breath-hold radiation therapy.
    Alderliesten T; Sonke JJ; Betgen A; Honnef J; van Vliet-Vroegindeweij C; Remeijer P
    Int J Radiat Oncol Biol Phys; 2013 Feb; 85(2):536-42. PubMed ID: 22652107
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Estimation of heart-position variability in 3D-surface-image-guided deep-inspiration breath-hold radiation therapy for left-sided breast cancer.
    Alderliesten T; Betgen A; Elkhuizen PH; van Vliet-Vroegindeweij C; Remeijer P
    Radiother Oncol; 2013 Dec; 109(3):442-7. PubMed ID: 24161569
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correlation between the setting of gating window width and setup accuracy in left breast cancer radiotherapy based on deep inspiration breath hold.
    Yucheng L; Yibo S; Wenming Z; Yongshi J; Qiang L; Lingyun Q; Liu H; Zhang Y; Jieni D; Weijun C
    J Appl Clin Med Phys; 2023 Nov; 24(11):e14116. PubMed ID: 37538022
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric advantages of volumetric modulated arc therapy (VMAT) with deep inspiration breath hold (DIBH) technique in Halcyon Linac for left breast cancer treatment.
    Cheung AP; Lei MM; Lee SS; Hung WK; Chiu CW; Qiu XB; Chau RM
    Med Dosim; 2022 Autumn; 47(3):288-294. PubMed ID: 35641365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: initial experience.
    Duggan DM; Ding GX; Coffey CW; Kirby W; Hallahan DE; Malcolm A; Lu B
    Lung Cancer; 2007 Apr; 56(1):77-88. PubMed ID: 17169461
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of surface image guidance and Deep inspiration Breath Hold technique for breast treatments with Halcyon.
    Crop F; Laffarguette J; Achag I; Pasquier D; Mirabel X; Cayez R; Lacornerie T
    Phys Med; 2023 Apr; 108():102564. PubMed ID: 36989980
    [TBL] [Abstract][Full Text] [Related]  

  • 14. AlignRT
    Laaksomaa M; Sarudis S; Rossi M; Lehtonen T; Pehkonen J; Remes J; Luukkanen H; Skyttä T; Kapanen M
    J Appl Clin Med Phys; 2019 Mar; 20(3):97-104. PubMed ID: 30861276
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a proprietary software application for motion monitoring during stereotactic paraspinal treatment.
    Fan Q; Pham H; Zhang P; Li X; Li T
    J Appl Clin Med Phys; 2022 Jun; 23(6):e13594. PubMed ID: 35338583
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Geometrical uncertainty of heart position in deep-inspiration breath-hold radiotherapy of left-sided breast cancer patients.
    Koivumäki T; Tujunen J; Virén T; Heikkilä J; Seppälä J
    Acta Oncol; 2017 Jun; 56(6):879-883. PubMed ID: 28281859
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated review of patient position in DIBH breast hybrid IMRT with EPID images.
    Redekopp J; Rivest R; Sasaki D; Pistorius S; Alpuche Aviles JE
    J Appl Clin Med Phys; 2023 Sep; 24(9):e14038. PubMed ID: 37449391
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiotherapy patients.
    Li H; Zhu XR; Zhang L; Dong L; Tung S; Ahamad A; Chao KS; Morrison WH; Rosenthal DI; Schwartz DL; Mohan R; Garden AS
    Int J Radiat Oncol Biol Phys; 2008 Jul; 71(3):916-25. PubMed ID: 18395358
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy and potential improvements of surface-guided breast cancer radiotherapy in deep inspiration breath-hold with daily image-guidance.
    Nankali S; Hansen R; Worm E; Yates ES; Thomsen MS; Offersen B; Poulsen PR
    Phys Med Biol; 2022 Sep; 67(19):. PubMed ID: 36084626
    [No Abstract]   [Full Text] [Related]  

  • 20. Reproducibility of chestwall and heart position using surface-guided versus RPM-guided DIBH radiotherapy for left breast cancer.
    Lu W; Li G; Hong L; Yorke E; Tang X; Mechalakos JG; Zhang P; Cerviño LI; Powell S; Berry SL
    J Appl Clin Med Phys; 2023 Jan; 24(1):e13755. PubMed ID: 35993318
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.