These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 3753876)

  • 1. Gaseous homeostasis and the circle system. Description of a model.
    Conway CM
    Br J Anaesth; 1986 Mar; 58(3):330-6. PubMed ID: 3753876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gaseous homeostasis and the circle system. Factors influencing anaesthetic gas exchange.
    Conway CM
    Br J Anaesth; 1986 Oct; 58(10):1167-80. PubMed ID: 3768230
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alveolar gas relationships during use of the circle system with carbon dioxide absorption.
    Conway CM
    Br J Anaesth; 1981 Nov; 53(11):1135-46. PubMed ID: 6798983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Factors affecting carbon dioxide homeostasis during controlled ventilation with circle systems.
    Schoonbee CG; Conway CM
    Br J Anaesth; 1981 May; 53(5):471-7. PubMed ID: 6786313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A theoretical study of gaseous homeostasis in the Magill circuit.
    Conway CM
    Br J Anaesth; 1976 May; 48(5):441-5. PubMed ID: 1276016
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nonlinear identification of the PCO2 control system in man.
    Noshiro M; Furuya M; Linkens D; Goode K
    Comput Methods Programs Biomed; 1993 Jul; 40(3):189-202. PubMed ID: 8243076
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Special aspects of pharmacokinetics of inhalation anesthesia.
    Hendrickx JF; De Wolf A
    Handb Exp Pharmacol; 2008; (182):159-86. PubMed ID: 18175091
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An evaluation of fresh gas flow rates for spontaneously breathing cats and small dogs on the Humphrey ADE semi-closed breathing system.
    Gale E; Ticehurst KE; Zaki S
    Vet Anaesth Analg; 2015 May; 42(3):292-8. PubMed ID: 25039422
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physiologically precise simulation of multiple lung gas exchange during anaesthesia by simultaneous gas infusion and extraction.
    Peyton P; Ramani P; Stuart-Andrews C; Junor P; Robinson G
    Physiol Meas; 2005 Dec; 26(6):965-78. PubMed ID: 16311445
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Ruben circle anaesthesia system. An investigation of reverse flow of patient expired gas during spontaneous breathing.
    Sik MJ; Eveleigh DJ; Lewis RB
    Anaesthesia; 1988 Feb; 43(2):141-5. PubMed ID: 3128138
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An experimental study of gaseous homeostasis and the Magill circuit using low fresh gas flows.
    Conway CM; Davis FM; Knight HJ; Leigh JM; Preston TD; Tennant R
    Br J Anaesth; 1976 May; 48(5):447-55. PubMed ID: 1276017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Respiratory gas exchange. Anesthesia with enflurane or isoflurane in nitrous oxide during spontaneous and controlled ventilation].
    Bengtson JP; Arnestad JP; Bengtsson J; Bengtsson A; Stenqvist O
    Anaesthesist; 1993 May; 42(5):273-9. PubMed ID: 8317683
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A coaxial circle circuit: comparison with conventional circle and Bain circuit.
    Shandro J
    Can Anaesth Soc J; 1982 Mar; 29(2):121-5. PubMed ID: 7066735
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gaseous homeostasis and the circle system. Validation of a model.
    Conway CM
    Br J Anaesth; 1986 Mar; 58(3):337-44. PubMed ID: 3947497
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Anesthetic gas consumption and costs in a closed system with the PhysioFlex anesthesia equipment].
    Biro P
    Anaesthesist; 1993 Sep; 42(9):638-43. PubMed ID: 8214536
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Randomized comparison of three methods of induction of anaesthesia with sevoflurane.
    Knaggs CL; Drummond GB
    Br J Anaesth; 2005 Aug; 95(2):178-82. PubMed ID: 15863438
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Recent advances in uptake and excretion of inhalation anesthetics.
    Salanitre E; Rackow H
    Clin Anesth; 1969; 3():159-97. PubMed ID: 4941526
    [No Abstract]   [Full Text] [Related]  

  • 18. Clinical applications of low flow and closed circuit anesthesia.
    Baum J
    Acta Anaesthesiol Belg; 1990; 41(3):239-47. PubMed ID: 2260429
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory pattern and rebreathing in the Mapleson A, C and D breathing systems with spontaneous ventilation. A theory.
    Cook LB
    Anaesthesia; 1996 Apr; 51(4):371-85. PubMed ID: 8686829
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous measurement of gas uptake and elimination in anesthetized patients using an extractable marker gas.
    Robinson GJ; Peyton PJ; Terry D; Malekzadeh S; Thompson B
    J Appl Physiol (1985); 2004 Sep; 97(3):960-6. PubMed ID: 15333627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.