These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 37553847)

  • 21. The Effects of Free Heme on Functional and Molecular Changes During
    Hosgood SA; Elliott TR; Jordan NP; Nicholson ML
    Front Immunol; 2022; 13():849742. PubMed ID: 35585981
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Metformin Preconditioning and Postconditioning to Reduce Ischemia Reperfusion Injury in an Isolated Ex Vivo Rat and Porcine Kidney Normothermic Machine Perfusion Model.
    Huijink TM; Venema LH; Posma RA; de Vries NJ; Westerkamp AC; Ottens PJ; Touw DJ; Nijsten MW; Leuvenink HGD
    Clin Transl Sci; 2021 Jan; 14(1):222-230. PubMed ID: 32702185
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Study on the preservation effects of the amputated forelimb by machine perfusion at physiological temperature.
    Chen SF; Yang BY; Zhang TY; Song XY; Jia ZB; Chen LJ; Cui MY; Xu WJ; Peng J
    Chin J Traumatol; 2024 Mar; 27(2):114-120. PubMed ID: 37311687
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Impact of Red Blood Cells on Function and Metabolism of Porcine Deceased Donor Kidneys During Normothermic Machine Perfusion.
    Venema LH; van Leeuwen LL; Posma RA; van Goor H; Ploeg RJ; Hannaert P; Hauet T; Minor T; Leuvenink HGD;
    Transplantation; 2022 Jun; 106(6):1170-1179. PubMed ID: 34456268
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Protective role of normothermic machine perfusion during reduced-size liver transplantation in pigs.
    Zhang ZB; Gao W; Shi Y; Liu L; Ma N; Chen J; Zhu ZJ
    Liver Transpl; 2016 Jul; 22(7):968-78. PubMed ID: 27037634
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Avoiding initial hypothermia does not improve liver graft quality in a porcine donation after circulatory death (DCD) model of normothermic perfusion.
    Nostedt JJ; Churchill T; Ghosh S; Thiesen A; Hopkins J; Lees MC; Adam B; Freed DH; Shapiro AMJ; Bigam DL
    PLoS One; 2019; 14(8):e0220786. PubMed ID: 31386697
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Normothermic Machine Perfusion Protects Against Liver Ischemia-Reperfusion Injury During Reduced-Size Liver Transplantation in Pigs.
    Zhang ZB; Gao W; Liu L; Shi Y; Ma N; Huai MS; Shen ZY
    Ann Transplant; 2019 Jan; 24():9-17. PubMed ID: 30607000
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prolonged Controlled Oxygenated Rewarming Improves Immediate Tubular Function and Energetic Recovery of Porcine Kidneys During Normothermic Machine Perfusion.
    Ogurlu B; Pamplona CC; Van Tricht IM; Hamelink TL; Lantinga VA; Leuvenink HGD; Moers C; Pool MBF
    Transplantation; 2023 Mar; 107(3):639-647. PubMed ID: 36525548
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Controlled Oxygenated Rewarming Compensates for Cold Storage-induced Dysfunction in Kidney Grafts.
    von Horn C; Zlatev H; Kaths M; Paul A; Minor T
    Transplantation; 2022 May; 106(5):973-978. PubMed ID: 34172643
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Preliminary Single-Center Canadian Experience of Human Normothermic Ex Vivo Liver Perfusion: Results of a Clinical Trial.
    Bral M; Gala-Lopez B; Bigam D; Kneteman N; Malcolm A; Livingstone S; Andres A; Emamaullee J; Russell L; Coussios C; West LJ; Friend PJ; Shapiro AM
    Am J Transplant; 2017 Apr; 17(4):1071-1080. PubMed ID: 27639262
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Use of ex vivo normothermic machine perfusion after normothermic regional perfusion to salvage a poorly perfused DCD kidney.
    Georgiades F; Hosgood SA; Butler AJ; Nicholson ML
    Am J Transplant; 2019 Dec; 19(12):3415-3419. PubMed ID: 31355509
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ex vivo normothermic machine perfusion is safe, simple, and reliable: results from a large animal model.
    Nassar A; Liu Q; Farias K; D'Amico G; Tom C; Grady P; Bennett A; Diago Uso T; Eghtesad B; Kelly D; Fung J; Abu-Elmagd K; Miller C; Quintini C
    Surg Innov; 2015 Feb; 22(1):61-9. PubMed ID: 24694840
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Normothermic machine perfusion of the kidney.
    Weissenbacher A; Hunter J
    Curr Opin Organ Transplant; 2017 Dec; 22(6):571-576. PubMed ID: 28901972
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Assessment of Mitochondrial Function and Oxygen Consumption Measured During
    Hunter JP; Faro LL; Rozenberg K; Dengu F; Ogbemudia A; Weissenbacher A; Mulvey JF; Knijff L; Gopalakrishnan K; Ploeg RJ
    Transpl Int; 2022; 35():10420. PubMed ID: 35711321
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Physiological effects of altering oxygenation during kidney normothermic machine perfusion.
    Adams TD; Hosgood SA; Nicholson ML
    Am J Physiol Renal Physiol; 2019 May; 316(5):F823-F829. PubMed ID: 30785351
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cytochrome P450 2E1 predicts liver functional recovery from donation after circulatory death using air-ventilated normothermic machine perfusion.
    Shi JH; Yang DJ; Jin Q; Cheng N; Shi YB; Bai Y; Yu DS; Guo WZ; Ge GB; Zhang SJ
    Sci Rep; 2022 May; 12(1):7446. PubMed ID: 35523980
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Liver Transplantation After Ex Vivo Normothermic Machine Preservation: A Phase 1 (First-in-Man) Clinical Trial.
    Ravikumar R; Jassem W; Mergental H; Heaton N; Mirza D; Perera MT; Quaglia A; Holroyd D; Vogel T; Coussios CC; Friend PJ
    Am J Transplant; 2016 Jun; 16(6):1779-87. PubMed ID: 26752191
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Infusing Mesenchymal Stromal Cells into Porcine Kidneys during Normothermic Machine Perfusion: Intact MSCs Can Be Traced and Localised to Glomeruli.
    Pool M; Eertman T; Sierra Parraga J; 't Hart N; Roemeling-van Rhijn M; Eijken M; Jespersen B; Reinders M; Hoogduijn M; Ploeg R; Leuvenink H; Moers C
    Int J Mol Sci; 2019 Jul; 20(14):. PubMed ID: 31340593
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Initial perfusate purification during subnormothermic machine perfusion for porcine liver donated after cardiac death.
    Obara H; Morito N; Matsuno N; Yoshikawa R; Nakajo T; Gochi M; Otani M; Shonaka T; Furukawa H; Hirano T; Enosawa S
    J Artif Organs; 2020 Mar; 23(1):62-69. PubMed ID: 31392524
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pilot, Open, Randomized, Prospective Trial for Normothermic Machine Perfusion Evaluation in Liver Transplantation From Older Donors.
    Ghinolfi D; Rreka E; De Tata V; Franzini M; Pezzati D; Fierabracci V; Masini M; Cacciatoinsilla A; Bindi ML; Marselli L; Mazzotti V; Morganti R; Marchetti P; Biancofiore G; Campani D; Paolicchi A; De Simone P
    Liver Transpl; 2019 Mar; 25(3):436-449. PubMed ID: 30362649
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.