295 related articles for article (PubMed ID: 37558748)
1. Image-free handheld robotic-assisted technology improved the accuracy of implant positioning compared to conventional instrumentation in patients undergoing simultaneous bilateral total knee arthroplasty, without additional benefits in improvement of clinical outcomes.
Albelooshi A; Hamie M; Bollars P; Althani S; Salameh R; Almasri M; Schotanus MGM; Meshram P
Knee Surg Sports Traumatol Arthrosc; 2023 Nov; 31(11):4833-4841. PubMed ID: 37558748
[TBL] [Abstract][Full Text] [Related]
2. Improved accuracy of implant placement with an imageless handheld robotic system compared to conventional instrumentation in patients undergoing total knee arthroplasty: a prospective randomized controlled trial using CT-based assessment of radiological outcomes.
Bollars P; Janssen D; De Weerdt W; Albelooshi A; Meshram P; Nguyen TD; Lacour MT; Schotanus MGM
Knee Surg Sports Traumatol Arthrosc; 2023 Dec; 31(12):5446-5452. PubMed ID: 37796307
[TBL] [Abstract][Full Text] [Related]
3. Early Clinical and Radiographic Outcomes of Robot-Assisted Versus Conventional Manual Total Knee Arthroplasty: A Randomized Controlled Study.
Xu J; Li L; Fu J; Xu C; Ni M; Chai W; Hao L; Zhang G; Chen J
Orthop Surg; 2022 Sep; 14(9):1972-1980. PubMed ID: 35848154
[TBL] [Abstract][Full Text] [Related]
4. Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial.
Vaidya NV; Deshpande AN; Panjwani T; Patil R; Jaysingani T; Patil P
Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):621-626. PubMed ID: 33165631
[TBL] [Abstract][Full Text] [Related]
5. Does Robotic-assisted TKA Result in Better Outcome Scores or Long-Term Survivorship Than Conventional TKA? A Randomized, Controlled Trial.
Kim YH; Yoon SH; Park JW
Clin Orthop Relat Res; 2020 Feb; 478(2):266-275. PubMed ID: 31389889
[TBL] [Abstract][Full Text] [Related]
6. Functional positioning principles for image-based robotic-assisted TKA achieved a higher Forgotten Joint Score at 1 year compared to conventional TKA with restricted kinematic alignment.
Kafelov M; Batailler C; Shatrov J; Al-Jufaili J; Farhat J; Servien E; Lustig S
Knee Surg Sports Traumatol Arthrosc; 2023 Dec; 31(12):5591-5602. PubMed ID: 37851026
[TBL] [Abstract][Full Text] [Related]
7. Image-Free Robotic-Assisted Total Knee Arthroplasty Improves Implant Alignment Accuracy: A Cadaveric Study.
Doan GW; Courtis RP; Wyss JG; Green EW; Clary CW
J Arthroplasty; 2022 Apr; 37(4):795-801. PubMed ID: 34979253
[TBL] [Abstract][Full Text] [Related]
8. Better accuracy and implant survival in medial imageless robotic-assisted unicompartmental knee arthroplasty compared to conventional unicompartmental knee arthroplasty: two- to eleven-year follow-up of three hundred fifty-six consecutive knees.
Foissey C; Batailler C; Vahabi A; Fontalis A; Servien E; Lustig S
Int Orthop; 2023 Feb; 47(2):533-541. PubMed ID: 36434294
[TBL] [Abstract][Full Text] [Related]
9. Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurements.
Kaneko T; Igarashi T; Takada K; Yoshizawa S; Ikegami H; Musha Y
Knee; 2021 Aug; 31():64-76. PubMed ID: 34118583
[TBL] [Abstract][Full Text] [Related]
10. Robotic-assisted total knee arthroplasty improves implant position and early functional recovery for the knee with severe varus/valgus deformity.
Yang Y; Jiang L; Zhou X; Zhou X; Chen H; Chen Z
BMC Musculoskelet Disord; 2024 Jan; 25(1):92. PubMed ID: 38267884
[TBL] [Abstract][Full Text] [Related]
11. Comparison of imageless robotic assisted total knee arthroplasty and conventional total knee arthroplasty: early clinical and radiological outcomes of 200 knees.
Rajasekaran S; Soundarrajan D; Singh R; Shiferaw BA; Rajasekaran RB; Dhanasekararaja P; Rajkumar N
J Robot Surg; 2024 Apr; 18(1):151. PubMed ID: 38564044
[TBL] [Abstract][Full Text] [Related]
12. Functional alignment with robotic‑arm assisted total knee arthroplasty demonstrated better patient-reported outcomes than mechanical alignment with manual total knee arthroplasty.
Choi BS; Kim SE; Yang M; Ro DH; Han HS
Knee Surg Sports Traumatol Arthrosc; 2023 Mar; 31(3):1072-1080. PubMed ID: 36378291
[TBL] [Abstract][Full Text] [Related]
13. [Effect of robotic-arm assisted total knee arthroplasty on femoral rotation alignment and its short-term effectiveness].
Sun M; Yang L; Guo L; He R
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Jul; 35(7):807-812. PubMed ID: 34308585
[TBL] [Abstract][Full Text] [Related]
14. How does the use of quantified gap-balancing affect component positioning and limb alignment in robotic total knee arthroplasty using functional alignment philosophy? A comparison of two robotic platforms.
Murphy GT; Shatrov J; Duong J; Fritsch BA
Int Orthop; 2023 May; 47(5):1221-1232. PubMed ID: 36740610
[TBL] [Abstract][Full Text] [Related]
15. Robotic-Assisted Total Knee Arthroplasty Utilizing NAVIO, CORI Imageless Systems and Manual TKA Accurately Restore Femoral Rotational Alignment and Yield Satisfactory Clinical Outcomes: A Randomized Controlled Trial.
Adamska O; Modzelewski K; Szymczak J; Świderek J; Maciąg B; Czuchaj P; Poniatowska M; Wnuk A
Medicina (Kaunas); 2023 Jan; 59(2):. PubMed ID: 36837438
[No Abstract] [Full Text] [Related]
16. Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques.
Deckey DG; Rosenow CS; Verhey JT; Brinkman JC; Mayfield CK; Clarke HD; Bingham JS
Bone Joint J; 2021 Jun; 103-B(6 Supple A):74-80. PubMed ID: 34053292
[TBL] [Abstract][Full Text] [Related]
17. An anatomo-functional implant positioning technique with robotic assistance for primary TKA allows the restoration of the native knee alignment and a natural functional ligament pattern, with a faster recovery at 6 months compared to an adjusted mechanical technique.
Parratte S; Van Overschelde P; Bandi M; Ozturk BY; Batailler C
Knee Surg Sports Traumatol Arthrosc; 2023 Apr; 31(4):1334-1346. PubMed ID: 35552475
[TBL] [Abstract][Full Text] [Related]
18. Image-Free Robotic-Assisted Total Knee Arthroplasty Results in Quicker Recovery but Equivalent One-Year Outcomes Compared to Conventional Total Knee Arthroplasty.
Khan IA; Vaile JR; DeSimone CA; Parsell DE; Heinze JD; Alessi A; Xu W; Shah RP; Pickering T; Cafferky NL; Lonner JH
J Arthroplasty; 2023 Jun; 38(6S):S232-S237. PubMed ID: 36801477
[TBL] [Abstract][Full Text] [Related]
19. Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study.
Batailler C; Anderson MB; Flecher X; Ollivier M; Parratte S
Arch Orthop Trauma Surg; 2023 Mar; 143(3):1599-1609. PubMed ID: 35536354
[TBL] [Abstract][Full Text] [Related]
20. Improved Component Placement Accuracy with Robotic-Arm Assisted Total Knee Arthroplasty.
Mahoney O; Kinsey T; Sodhi N; Mont MA; Chen AF; Orozco F; Hozack W
J Knee Surg; 2022 Feb; 35(3):337-344. PubMed ID: 32869232
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]