These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 37559221)

  • 1. Do Long-Segment Blocking Screws Increase the Stability of Intramedullary Nail Fixation in Proximal Tibia Fractures, Eliminating the "Bell-Clapper Effect?".
    Stenquist DS; McCaskey M; Diaz M; Munassi SD; Ayala G; Donohue D; Mir HR
    J Orthop Trauma; 2024 Jan; 38(1):e4-e8. PubMed ID: 37559221
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the "Bell-Clapper Effect".
    Auston D; Donohue D; Stoops K; Cox J; Diaz M; Santoni B; Mir H
    J Orthop Trauma; 2018 Nov; 32(11):559-564. PubMed ID: 30086037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model.
    Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M
    Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A New Technique for Placement of Blocking Screws and its Mechanical Effect on Stability of Tibia Fractures with Distal Fragments after Insertion of Small-Diameter Intramedullary Nails.
    Zhang CM; Sun L; Wang Q; Huang Q; Lin H; Duan N; Zhang CC; Ma T; Xue HZ; Zhang K; Li Z
    Orthop Surg; 2021 Oct; 13(7):2127-2136. PubMed ID: 34596359
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails.
    Krettek C; Miclau T; Schandelmaier P; Stephan C; Möhlmann U; Tscherne H
    J Orthop Trauma; 1999 Nov; 13(8):550-3. PubMed ID: 10714781
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing.
    Chan DS; Nayak AN; Blaisdell G; James CR; Denard A; Miles J; Santoni BG
    J Orthop Trauma; 2015 Feb; 29(2):98-104. PubMed ID: 25072288
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of locked distal screws in retrograde nailing of osteoporotic distal femur fractures: a laboratory study using cadaver femurs.
    Tejwani NC; Park S; Iesaka K; Kummer F
    J Orthop Trauma; 2005 Jul; 19(6):380-3. PubMed ID: 16003196
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimal blocking screw placement for retrograde IM nail fixation of distal femur fracture: a standardized biomechanical study of "osteoporotic" synthetic bone.
    Yakkanti R; Kitchen J; Voor M; Nyland J; Hartley B
    Arch Orthop Trauma Surg; 2022 Dec; 142(12):3827-3835. PubMed ID: 34981191
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.
    Lowenberg DW; DeBaun MR; Behn A; Sox-Harris A
    Eur J Orthop Surg Traumatol; 2020 Oct; 30(7):1205-1213. PubMed ID: 32367222
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws.
    Ricci WM; O'Boyle M; Borrelli J; Bellabarba C; Sanders R
    J Orthop Trauma; 2001 May; 15(4):264-70. PubMed ID: 11371791
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.
    Kandemir U; Herfat S; Herzog M; Viscogliosi P; Pekmezci M
    J Orthop Trauma; 2017 Feb; 31(2):e49-e54. PubMed ID: 28129271
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fixation of distal tibia fracture through plating, nailing, and nailing with Poller screws: A comparative biomechanical-based experimental and numerical investigation.
    Baseri A; Bagheri MA; Rouhi G; Aghighi MR; Bagheri N
    Proc Inst Mech Eng H; 2020 Oct; 234(10):1129-1138. PubMed ID: 32650692
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modified tibial nails for treating distal tibia fractures.
    Gorczyca JT; McKale J; Pugh K; Pienkowski D
    J Orthop Trauma; 2002 Jan; 16(1):18-22. PubMed ID: 11782627
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fixation of Proximal Tibial Fractures with Intramedullary Nail and Immediate Weightbearing: A Beneficial Alternative.
    Force A; Tarpada S; Follett L; Dedhia N; Dimitroulias A; Sen MK
    Injury; 2024 Jun; 55(6):111530. PubMed ID: 38637188
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Proximal tibial fracture stability with intramedullary nail fixation using oblique interlocking screws.
    Laflamme GY; Heimlich D; Stephen D; Kreder HJ; Whyne CM
    J Orthop Trauma; 2003 Aug; 17(7):496-502. PubMed ID: 12902787
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.