These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 37562275)

  • 21. Does Barbed Suture Repair Negate the Benefit of Peripheral Repair in Porcine Flexor Tendon?
    Sull A; Inceoglu S; Wongworawat MD
    Hand (N Y); 2016 Dec; 11(4):479-483. PubMed ID: 28149218
    [No Abstract]   [Full Text] [Related]  

  • 22. Evaluation of a new 4-strand flexor tendon repair in a cadaveric porcine model.
    Manchio JV; Shashikant MP; Shrivastava A; Weinzweig J; Vernadakis AJ
    J Hand Surg Am; 2009 Jan; 34(1):102-7. PubMed ID: 19058923
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The consistency and reliability of six-strand and four-strand flexor tendon repairs: a comparative porcine cadaveric study.
    Kuronen JAE; Riski B; Leppänen OV; Karjalainen T; Linnanmäki L
    J Hand Surg Eur Vol; 2022 May; 47(5):501-506. PubMed ID: 35001715
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The Impact of Suture Caliber and Looped Configurations on the Suture-Tendon Interface in Zone II Flexor Tendon Repair.
    Bernstein DT; Alexander JJ; Petersen NJ; Lambert BS; Noble PC; Netscher DT
    J Hand Surg Am; 2019 Feb; 44(2):156.e1-156.e8. PubMed ID: 29891271
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effects of tension across the tendon repair site on tendon gap and ultimate strength.
    Wu YF; Tang JB
    J Hand Surg Am; 2012 May; 37(5):906-12. PubMed ID: 22386548
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of four methods of flexor tendon repair for postoperative active mobilization.
    Tang JB; Gu YT; Rice K; Chen F; Pan CZ
    Plast Reconstr Surg; 2001 Mar; 107(3):742-9. PubMed ID: 11304600
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The mechanical interaction between three geometric types of nylon core suture and a running epitenon suture in repair of porcine flexor tendons.
    de Wit T; Walbeehm ET; Hovius SE; McGrouther DA
    J Hand Surg Eur Vol; 2013 Sep; 38(7):788-94. PubMed ID: 23649010
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of Flexor Tendon Suture Techniques Including 1 Using 10 Strands.
    Lee HI; Lee JS; Kim TH; Chang SH; Park MJ; Lee GJ
    J Hand Surg Am; 2015 Jul; 40(7):1369-76. PubMed ID: 26050206
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of the Optimal Asymmetry on the Strength of Six-Strand Tendon Repair: An Ex Vivo Biomechanical Study.
    Kozono N; Okada T; Takeuchi N; Shimoto T; Higaki H; Nakashima Y
    J Hand Surg Am; 2017 Apr; 42(4):250-256. PubMed ID: 28242243
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Asymmetric 6-Strand Flexor Tendon Repair - Biomechanical Analysis Using Barbed Suture.
    Lee JS; Wong YR; Tay SC
    J Hand Surg Asian Pac Vol; 2019 Sep; 24(3):297-302. PubMed ID: 31438796
    [No Abstract]   [Full Text] [Related]  

  • 31. Influence of the direction of suture strands on the tensile strength after flexor tendon repairs.
    Moriya K; Maki Y; Koda H; Kuroda T; Tsubokawa N
    J Hand Surg Eur Vol; 2023 Nov; 48(10):1074-1079. PubMed ID: 37416995
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy.
    Sull A; Inceoglu S; August A; Gregorius S; Wongworawat MD
    Hand (N Y); 2016 Dec; 11(4):475-478. PubMed ID: 28149217
    [No Abstract]   [Full Text] [Related]  

  • 33. The effect of barbed suture tendon repair on work of flexion.
    Ben-Amotz O; Kargel J; Mailey B; Sammer DM
    J Hand Surg Am; 2015 May; 40(5):969-74. PubMed ID: 25817753
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A knotless bidirectional-barbed tendon repair is inferior to conventional 4-strand repairs in cyclic loading.
    O'Brien FP; Parks BG; Tsai MA; Means KR
    J Hand Surg Eur Vol; 2016 Oct; 41(8):809-14. PubMed ID: 26936746
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Gliding characteristics and gap formation for locking and grasping tendon repairs: a biomechanical study in a human cadaver model.
    Tanaka T; Amadio PC; Zhao C; Zobitz ME; Yang C; An KN
    J Hand Surg Am; 2004 Jan; 29(1):6-14. PubMed ID: 14751096
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The role of multiple strands and locking sutures on gap formation of flexor tendon repairs during cyclical loading.
    Barrie KA; Tomak SL; Cholewicki J; Wolfe SW
    J Hand Surg Am; 2000 Jul; 25(4):714-20. PubMed ID: 10913213
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Flexor tendons repair: effect of core sutures caliber with increased number of suture strands and peripheral sutures. A sheep model.
    Uslu M; Isik C; Ozsahin M; Ozkan A; Yasar M; Orhan Z; Erkan Inanmaz M; Sarman H
    Orthop Traumatol Surg Res; 2014 Oct; 100(6):611-6. PubMed ID: 25130761
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical analysis of flexor tendon repair using knotted Kessler and Bunnell techniques and the knotless Bunnell technique.
    Jordan MC; Schmidt K; Meffert RH; Hoelscher-Doht S
    J Hand Surg Am; 2015 Jan; 40(1):115-20. PubMed ID: 25446999
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A 3-Dimensional Suture Technique for Flexor Tendon Repair: A Biomechanical Study.
    Castoldi M; Solla F; Camuzard O; Pithioux M; Rampal V; Rosello O
    J Hand Surg Am; 2023 Feb; 48(2):194.e1-194.e9. PubMed ID: 34848101
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair.
    Wieskötter B; Herbort M; Langer M; Raschke MJ; Wähnert D
    Arch Orthop Trauma Surg; 2018 Jan; 138(1):139-145. PubMed ID: 29134318
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.