BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 37574664)

  • 21. Superior objective and subjective image quality of deep learning reconstruction for low-dose abdominal CT imaging in comparison with model-based iterative reconstruction and filtered back projection.
    Tamura A; Mukaida E; Ota Y; Kamata M; Abe S; Yoshioka K
    Br J Radiol; 2021 Jul; 94(1123):20201357. PubMed ID: 34142867
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of moyamoya disease in CT angiography using ultra-high-resolution computed tomography: Application of deep learning reconstruction.
    Fukushima Y; Fushimi Y; Funaki T; Sakata A; Hinoda T; Nakajima S; Sakamoto R; Yoshida K; Miyamoto S; Nakamoto Y
    Eur J Radiol; 2022 Jun; 151():110294. PubMed ID: 35427840
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Model-based iterative reconstruction for 320-detector row CT angiography reduces radiation exposure in infants with complex congenital heart disease.
    Yamasaki Y; Kamitani T; Sagiyama K; Matsuura Y; Hida T; Nagata H
    Diagn Interv Radiol; 2021 Jan; 27(1):42-49. PubMed ID: 33290239
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Deep-learning reconstruction for ultra-low-dose lung CT: Volumetric measurement accuracy and reproducibility of artificial ground-glass nodules in a phantom study.
    Mikayama R; Shirasaka T; Kojima T; Sakai Y; Yabuuchi H; Kondo M; Kato T
    Br J Radiol; 2022 Feb; 95(1130):20210915. PubMed ID: 34908478
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Abdominopelvic CT Image Quality: Evaluation of Thin (0.5-mm) Slices Using Deep Learning Reconstruction.
    Oostveen LJ; Smit EJ; Dekker HM; Buckens CF; Pegge SAH; de Lange F; Sechopoulos I; Prokop M
    AJR Am J Roentgenol; 2023 Mar; 220(3):381-388. PubMed ID: 36259592
    [No Abstract]   [Full Text] [Related]  

  • 26. Value of deep learning reconstruction at ultra-low-dose CT for evaluation of urolithiasis.
    Zhang G; Zhang X; Xu L; Bai X; Jin R; Xu M; Yan J; Jin Z; Sun H
    Eur Radiol; 2022 Sep; 32(9):5954-5963. PubMed ID: 35357541
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Combination of Deep Learning-Based Denoising and Iterative Reconstruction for Ultra-Low-Dose CT of the Chest: Image Quality and Lung-RADS Evaluation.
    Hata A; Yanagawa M; Yoshida Y; Miyata T; Tsubamoto M; Honda O; Tomiyama N
    AJR Am J Roentgenol; 2020 Dec; 215(6):1321-1328. PubMed ID: 33052702
    [No Abstract]   [Full Text] [Related]  

  • 28. Noise power spectrum properties of deep learning-based reconstruction and iterative reconstruction algorithms: Phantom and clinical study.
    Funama Y; Nakaura T; Hasegawa A; Sakabe D; Oda S; Kidoh M; Nagayama Y; Hirai T
    Eur J Radiol; 2023 Aug; 165():110914. PubMed ID: 37295358
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Image quality improvement with deep learning-based reconstruction on abdominal ultrahigh-resolution CT: A phantom study.
    Shirasaka T; Kojima T; Funama Y; Sakai Y; Kondo M; Mikayama R; Hamasaki H; Kato T; Ushijima Y; Asayama Y; Nishie A
    J Appl Clin Med Phys; 2021 Jul; 22(7):286-296. PubMed ID: 34159736
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT.
    Akagi M; Nakamura Y; Higaki T; Narita K; Honda Y; Zhou J; Yu Z; Akino N; Awai K
    Eur Radiol; 2019 Nov; 29(11):6163-6171. PubMed ID: 30976831
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography.
    Oda S; Utsunomiya D; Funama Y; Yonenaga K; Namimoto T; Nakaura T; Yamashita Y
    AJR Am J Roentgenol; 2012 May; 198(5):1126-31. PubMed ID: 22528903
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning.
    Felmly LM; De Cecco CN; Schoepf UJ; Varga-Szemes A; Mangold S; McQuiston AD; Litwin SE; Bayer RR; Vogl TJ; Wichmann JL
    Eur Radiol; 2017 May; 27(5):1944-1953. PubMed ID: 27553939
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol.
    Ippolito D; Riva L; Talei Franzesi C; De Vito A; Cangiotti C; Crespi A; Corso R; Sironi S
    J Comput Assist Tomogr; 2020; 44(1):13-19. PubMed ID: 31939876
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Radiation dose optimization potential of deep learning-based reconstruction for multiphase hepatic CT: A clinical and phantom study.
    Nagayama Y; Goto M; Sakabe D; Emoto T; Shigematsu S; Taguchi N; Maruyama N; Takada S; Uchimura R; Hayashi H; Kidoh M; Oda S; Nakaura T; Funama Y; Hatemura M; Hirai T
    Eur J Radiol; 2022 Jun; 151():110280. PubMed ID: 35381567
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of four computed tomography reconstruction algorithms using a coronary artery phantom.
    Sawamura S; Kato S; Funama Y; Oda S; Mochizuki H; Inagaki S; Takeuchi Y; Morioka T; Izumi T; Ota Y; Kawagoe H; Cheng S; Nakayama N; Fukui K; Tsutsumi T; Iwasawa T; Utsunomiya D
    Quant Imaging Med Surg; 2024 Apr; 14(4):2870-2883. PubMed ID: 38617144
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical Advantages of Using Low Tube Voltage in Third-Generation 192-Slice Dual-Source Computed Tomographic Angiography Before Transcatheter Aortic Valve Implantation.
    Onoda H; Ueno H; Hashimoto M; Kuwahara H; Sobajima M; Kinugawa K
    Int Heart J; 2019 Sep; 60(5):1091-1097. PubMed ID: 31484865
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction.
    Brady SL; Trout AT; Somasundaram E; Anton CG; Li Y; Dillman JR
    Radiology; 2021 Jan; 298(1):180-188. PubMed ID: 33201790
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Image quality assessment of artificial intelligence iterative reconstruction for low dose aortic CTA: A feasibility study of 70 kVp and reduced contrast medium volume.
    Li W; You Y; Zhong S; Shuai T; Liao K; Yu J; Zhao J; Li Z; Lu C
    Eur J Radiol; 2022 Apr; 149():110221. PubMed ID: 35196615
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window.
    Wang J; Sui X; Zhao R; Du H; Wang J; Wang Y; Qin R; Lu X; Ma Z; Xu Y; Jin Z; Song L; Song W
    Eur Radiol; 2024 Feb; 34(2):1053-1064. PubMed ID: 37581663
    [TBL] [Abstract][Full Text] [Related]  

  • 40. High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses.
    Li W; Diao K; Wen Y; Shuai T; You Y; Zhao J; Liao K; Lu C; Yu J; He Y; Li Z
    Eur Radiol; 2022 May; 32(5):2912-2920. PubMed ID: 35059803
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.