220 related articles for article (PubMed ID: 3757531)
1. Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance.
Bernstein DP
Crit Care Med; 1986 Oct; 14(10):898-901. PubMed ID: 3757531
[TBL] [Abstract][Full Text] [Related]
2. A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography.
Marik PE; Pendelton JE; Smith R
Crit Care Med; 1997 Sep; 25(9):1545-50. PubMed ID: 9295830
[TBL] [Abstract][Full Text] [Related]
3. Reproducibility and comparison of cardiac output measurement by transthoracic bioimpedance and thermodilution methods in critically ill patients.
Ng HW; Coleman N; Walley TJ; Mostafa SM; Breckenridge AM
Clin Intensive Care; 1993; 4(5):217-21. PubMed ID: 10146700
[TBL] [Abstract][Full Text] [Related]
4. Continuous non-invasive measurement of stroke volume and cardiac index in infants and children: comparison of Impedance Cardiography NICaS® vs CardioQ® method.
Beck R; Milella L; Labellarte C
Clin Ter; 2018; 169(3):e110-e113. PubMed ID: 29938742
[TBL] [Abstract][Full Text] [Related]
5. Determination of cardiac output during positive end-expiratory pressure--noninvasive electrical bioimpedance compared with standard thermodilution.
Castor G; Molter G; Helms J; Niedermark I; Altmayer P
Crit Care Med; 1990 May; 18(5):544-6. PubMed ID: 2183967
[TBL] [Abstract][Full Text] [Related]
6. Cardiac Output Measurement in Neonates and Children Using Noninvasive Electrical Bioimpedance Compared With Standard Methods: A Systematic Review and Meta-Analysis.
Mansfield RC; Kaza N; Charalambous A; Milne AC; Sathiyamurthy S; Banerjee J
Crit Care Med; 2022 Jan; 50(1):126-137. PubMed ID: 34325447
[TBL] [Abstract][Full Text] [Related]
7. Transthoracic electrical bioimpedence cardiac output: comparison with multigated equillibrium radionuclide cardiography.
Gujjar AR; Muralidhar K; Bhandopadhyaya A; Sathyaprabha TN; Janaki P; Mahalla BK; Gupta R; Banakal S; Jairaj PS
J Clin Monit Comput; 2010 Apr; 24(2):155-9. PubMed ID: 20229061
[TBL] [Abstract][Full Text] [Related]
8. Cardiac output measurement in critical care patients: Thoracic Electrical Bioimpedance versus thermodilution.
Clancy TV; Norman K; Reynolds R; Covington D; Maxwell JG
J Trauma; 1991 Aug; 31(8):1116-20; discussion 1120-1. PubMed ID: 1875438
[TBL] [Abstract][Full Text] [Related]
9. The accuracy of bioimpedance cardiography in the measurement of cardiac output in comparison with thermodilution method.
Wong KL; Hou PC
Acta Anaesthesiol Sin; 1996 Jun; 34(2):55-9. PubMed ID: 9084523
[TBL] [Abstract][Full Text] [Related]
10. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation.
Preiser JC; Daper A; Parquier JN; Contempré B; Vincent JL
Intensive Care Med; 1989; 15(4):221-3. PubMed ID: 2745864
[TBL] [Abstract][Full Text] [Related]
11. Cardiac output determinations in the pig--thoracic electrical bioimpedance versus thermodilution.
Jivegård L; Frid I; Haljamäe H; Holm J; Holm S; Wickström I
Crit Care Med; 1990 Sep; 18(9):995-8. PubMed ID: 2394124
[TBL] [Abstract][Full Text] [Related]
12. Comparison of thermodilution and transthoracic electrical bioimpedance cardiac outputs.
Woo MA; Hamilton M; Stevenson LW; Vredevoe DL
Heart Lung; 1991 Jul; 20(4):357-62. PubMed ID: 2071427
[TBL] [Abstract][Full Text] [Related]
13. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution.
Suttner S; Schöllhorn T; Boldt J; Mayer J; Röhm KD; Lang K; Piper SN
Intensive Care Med; 2006 Dec; 32(12):2053-8. PubMed ID: 17039348
[TBL] [Abstract][Full Text] [Related]
14. Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution.
Jewkes C; Sear JW; Verhoeff F; Sanders DJ; Foëx P
Br J Anaesth; 1991 Dec; 67(6):788-94. PubMed ID: 1768552
[TBL] [Abstract][Full Text] [Related]
15. The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review.
Newman DG; Callister R
Aviat Space Environ Med; 1999 Aug; 70(8):780-9. PubMed ID: 10447052
[TBL] [Abstract][Full Text] [Related]
16. [Noninvasive evaluation of cardiac index and ejection fraction in ischemic heart disease. Comparison of thoracic bioimpedance, thermodilution and cineventriculography].
Talarico G; Saino A; Lotto A
Minerva Cardioangiol; 1992 Jun; 40(6):203-9. PubMed ID: 1407614
[TBL] [Abstract][Full Text] [Related]
17. Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy.
Belardinelli R; Ciampani N; Costantini C; Blandini A; Purcaro A
Am J Cardiol; 1996 Jun; 77(15):1293-301. PubMed ID: 8677869
[TBL] [Abstract][Full Text] [Related]
18. Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations.
Pickett BR; Buell JC
Am J Cardiol; 1992 May; 69(16):1354-8. PubMed ID: 1585872
[TBL] [Abstract][Full Text] [Related]
19. Signal processing technique for non-invasive real-time estimation of cardiac output by inductance cardiography (thoracocardiography).
Bucklar GB; Kaplan V; Bloch KE
Med Biol Eng Comput; 2003 May; 41(3):302-9. PubMed ID: 12803295
[TBL] [Abstract][Full Text] [Related]
20. Noninvasive whole-body electrical bioimpedance cardiac output and invasive thermodilution cardiac output in high-risk surgical patients.
Imhoff M; Lehner JH; Löhlein D
Crit Care Med; 2000 Aug; 28(8):2812-8. PubMed ID: 10966255
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]