117 related articles for article (PubMed ID: 37578158)
1. Practical approaches to the detection of macrotroponin.
Lam L; Kyle C
Ann Clin Biochem; 2024 Mar; 61(2):122-132. PubMed ID: 37578158
[TBL] [Abstract][Full Text] [Related]
2. Effect of Macrotroponin in a Cohort of Community Patients with Elevated Cardiac Troponin.
Lam L; Tse R; Gladding P; Kyle C
Clin Chem; 2022 Oct; 68(10):1261-1271. PubMed ID: 35929566
[TBL] [Abstract][Full Text] [Related]
3. Change in troponin concentrations in patients with macrotroponin: An in vitro mixing study.
Lam L; Heron C; Aspin L; Ha L; Kyle CV
Clin Biochem; 2020 Nov; 85():43-48. PubMed ID: 32861681
[TBL] [Abstract][Full Text] [Related]
4. Effect of macrotroponin on the utility of cardiac troponin I as a prognostic biomarker for long term total and cardiovascular disease mortality.
Lam L; Ha L; Gladding P; Tse R; Kyle C
Pathology; 2021 Dec; 53(7):860-866. PubMed ID: 34272050
[TBL] [Abstract][Full Text] [Related]
5. Identification of macrotroponin T: findings from a case report and non-reproducible troponin T results.
Lam L; Ha L; Heron C; Chiu W; Kyle C
Clin Chem Lab Med; 2021 Nov; 59(12):1972-1980. PubMed ID: 34496163
[TBL] [Abstract][Full Text] [Related]
6. Discrepancy between Cardiac Troponin Assays Due to Endogenous Antibodies.
Lam L; Aspin L; Heron RC; Ha L; Kyle C
Clin Chem; 2020 Mar; 66(3):445-454. PubMed ID: 32031592
[TBL] [Abstract][Full Text] [Related]
7. Macrotroponins cause discrepancy in high-sensitivity examination.
Broz P; Racek J; Prokop P; Novak J; Rajdl D; Trefil L
Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2024 Jun; 168(2):187-190. PubMed ID: 36628561
[TBL] [Abstract][Full Text] [Related]
8. Analytical assessment of ortho clinical diagnostics high-sensitivity cardiac troponin I assay.
Kavsak PA; Edge T; Roy C; Malinowski P; Bamford K; Clark L; Lamers S; Hill S; Worster A
Clin Chem Lab Med; 2021 Mar; 59(4):749-755. PubMed ID: 33079697
[TBL] [Abstract][Full Text] [Related]
9. High incidence of macrotroponin I with a high-sensitivity troponin I assay.
Warner JV; Marshall GA
Clin Chem Lab Med; 2016 Nov; 54(11):1821-1829. PubMed ID: 27092651
[TBL] [Abstract][Full Text] [Related]
10. False positive troponin result caused by a true macrotroponin.
Michielsen EC; Bisschops PG; Janssen MJ
Clin Chem Lab Med; 2011 May; 49(5):923-5. PubMed ID: 21388341
[TBL] [Abstract][Full Text] [Related]
11. Clinical Validation of a Novel High-Sensitivity Cardiac Troponin I Assay for Early Diagnosis of Acute Myocardial Infarction.
Boeddinghaus J; Twerenbold R; Nestelberger T; Badertscher P; Wildi K; Puelacher C; du Fay de Lavallaz J; Keser E; Rubini Giménez M; Wussler D; Kozhuharov N; Rentsch K; Miró Ò; Martin-Sanchez FJ; Morawiec B; Stefanelli S; Geigy N; Keller DI; Reichlin T; Mueller C;
Clin Chem; 2018 Sep; 64(9):1347-1360. PubMed ID: 29941469
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Siemens ADVIA Centaur high-sensitivity cardiac troponin I assay in serum.
Kavsak PA; Worster A; Hill SA; Jaffe AS
Clin Chim Acta; 2018 Dec; 487():216-221. PubMed ID: 30296440
[TBL] [Abstract][Full Text] [Related]
13. Clinical Evaluation of a New High-Sensitivity Cardiac Troponin I Assay for Diagnosis and Risk Assessment of Patients with Suspected Acute Myocardial Infarction.
Shiozaki M; Inoue K; Suwa S; Lee CC; Chiang SJ; Sato A; Fukuda K; Kubota N; Tamura H; Fujiwara Y; Yamaguchi K; Sato T; Sumiyoshi M; Daida H
Cardiology; 2021; 146(2):172-178. PubMed ID: 33461202
[TBL] [Abstract][Full Text] [Related]
14. Sample matrix and high-sensitivity cardiac troponin I assays.
Kavsak PA; Roy C; Malinowski P; Clark L; Lamers S; Bamford K; Hill S; Worster A; Jaffe AS
Clin Chem Lab Med; 2019 Apr; 57(5):745-751. PubMed ID: 30838842
[TBL] [Abstract][Full Text] [Related]
15. Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay.
Kavsak PA; MacCuish J; Boreyko J; Roy C; Lamers S; Clark L
Clin Biochem; 2019 Jul; 69():52-56. PubMed ID: 31063741
[TBL] [Abstract][Full Text] [Related]
16. Macrocomplexes and discordant high-sensitivity cardiac troponin concentrations.
Kavsak PA; Roy C; Malinowski P; Mark CT; Scott T; Clark L; Lamers S; Ainsworth C
Ann Clin Biochem; 2018 Jul; 55(4):500-504. PubMed ID: 28920468
[TBL] [Abstract][Full Text] [Related]
17. Monthly reference change value of cardiac troponin in hemodialysis patients as a useful tool for long-term cardiovascular management.
Badiou S; Boudet A; Leray-Moragues H; Rodriguez A; Bargnoux AS; Dupuy AM; Cristol JP
Clin Biochem; 2016 Oct; 49(15):1195-1198. PubMed ID: 27209376
[TBL] [Abstract][Full Text] [Related]
18. Independent and combined effects of biotin and hemolysis on high-sensitivity cardiac troponin assays.
Harley K; Bissonnette S; Inzitari R; Schulz K; Apple FS; Kavsak PA; Gunsolus IL
Clin Chem Lab Med; 2021 Jul; 59(8):1431-1443. PubMed ID: 33761581
[TBL] [Abstract][Full Text] [Related]
19. Analytical comparison of three different versions of a high-sensitivity cardiac troponin I assay over 10years.
Kavsak PA; Worster A; Hill SA; MacRae AR; Jaffe AS
Clin Chim Acta; 2017 Dec; 475():51-55. PubMed ID: 29017768
[TBL] [Abstract][Full Text] [Related]
20. Reference population and marathon runner sera assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and I assays.
Mingels A; Jacobs L; Michielsen E; Swaanenburg J; Wodzig W; van Dieijen-Visser M
Clin Chem; 2009 Jan; 55(1):101-8. PubMed ID: 18988757
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]