These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 37578926)

  • 41. A Cross-Subject SSVEP-BCI Based on Task Related Component Analysis.
    Liu W; Ke Y; Liu P; Du J; Kong L; Liu S; An X; Ming D
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():3022-3025. PubMed ID: 31946525
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Cross Domain Correlation Maximization for Enhancing the Target Recognition of SSVEP-Based Brain-Computer Interfaces.
    Lan W; Wang R; He Y; Zong Y; Leng Y; Iramina K; Zheng W; Ge S
    IEEE Trans Neural Syst Rehabil Eng; 2023; 31():3545-3555. PubMed ID: 37639414
    [TBL] [Abstract][Full Text] [Related]  

  • 43. An amplitude-modulated visual stimulation for reducing eye fatigue in SSVEP-based brain-computer interfaces.
    Chang MH; Baek HJ; Lee SM; Park KS
    Clin Neurophysiol; 2014 Jul; 125(7):1380-91. PubMed ID: 24368034
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Periodic component analysis as a spatial filter for SSVEP-based brain-computer interface.
    Kiran Kumar GR; Ramasubba Reddy M
    J Neurosci Methods; 2018 Sep; 307():164-174. PubMed ID: 29890196
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Spatial Filtering in SSVEP-Based BCIs: Unified Framework and New Improvements.
    Wong CM; Wang B; Wang Z; Lao KF; Rosa A; Wan F
    IEEE Trans Biomed Eng; 2020 Nov; 67(11):3057-3072. PubMed ID: 32091986
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Adaptive Window Method Based on FBCCA for Optimal SSVEP Recognition.
    Lee T; Nam S; Hyun DJ
    IEEE Trans Neural Syst Rehabil Eng; 2023; 31():78-86. PubMed ID: 36306303
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A calibration-free c-VEP based BCI employing narrow-band random sequences.
    Zheng L; Dong Y; Tian S; Pei W; Gao X; Wang Y
    J Neural Eng; 2024 Apr; 21(2):. PubMed ID: 38513290
    [No Abstract]   [Full Text] [Related]  

  • 48. Enhancing detection of steady-state visual evoked potentials using individual training data.
    Wang Y; Nakanishi M; Wang YT; Jung TP
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():3037-40. PubMed ID: 25570631
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A L1 normalization enhanced dynamic window method for SSVEP-based BCIs.
    Zhou W; Liu A; Wu L; Chen X
    J Neurosci Methods; 2022 Oct; 380():109688. PubMed ID: 35973644
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Multi-scale noise transfer and feature frequency detection in SSVEP based on FitzHugh-Nagumo neuron system.
    Chen R; Xu G; Zhang X; Han C; Zhang S
    J Neural Eng; 2021 Oct; 18(5):. PubMed ID: 34592716
    [No Abstract]   [Full Text] [Related]  

  • 51. Complex sparse spatial filter for decoding mixed frequency and phase coded steady-state visually evoked potentials.
    Morikawa N; Tanaka T; Islam MR
    J Neurosci Methods; 2018 Jul; 304():1-10. PubMed ID: 29653130
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Denoising Autoencoder-Based Feature Extraction to Robust SSVEP-Based BCIs.
    Chen YJ; Chen PC; Chen SC; Wu CM
    Sensors (Basel); 2021 Jul; 21(15):. PubMed ID: 34372256
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Novel spatial filter for SSVEP-based BCI: A generated reference filter approach.
    Sözer AT; Fidan CB
    Comput Biol Med; 2018 May; 96():98-105. PubMed ID: 29554548
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Align and Pool for EEG Headset Domain Adaptation (ALPHA) to Facilitate Dry Electrode Based SSVEP-BCI.
    Liu B; Chen X; Li X; Wang Y; Gao X; Gao S
    IEEE Trans Biomed Eng; 2022 Feb; 69(2):795-806. PubMed ID: 34406934
    [TBL] [Abstract][Full Text] [Related]  

  • 55. An efficient CNN-LSTM network with spectral normalization and label smoothing technologies for SSVEP frequency recognition.
    Pan Y; Chen J; Zhang Y; Zhang Y
    J Neural Eng; 2022 Sep; 19(5):. PubMed ID: 36041426
    [No Abstract]   [Full Text] [Related]  

  • 56. Bidirectional Siamese correlation analysis method for enhancing the detection of SSVEPs.
    Zhang X; Qiu S; Zhang Y; Wang K; Wang Y; He H
    J Neural Eng; 2022 Aug; 19(4):. PubMed ID: 35853437
    [No Abstract]   [Full Text] [Related]  

  • 57. Sequence detection analysis based on canonical correlation for steady-state visual evoked potential brain computer interfaces.
    Cao L; Ju Z; Li J; Jian R; Jiang C
    J Neurosci Methods; 2015 Sep; 253():10-7. PubMed ID: 26014663
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A Training Data-Driven Canonical Correlation Analysis Algorithm for Designing Spatial Filters to Enhance Performance of SSVEP-Based BCIs.
    Wei Q; Zhu S; Wang Y; Gao X; Guo H; Wu X
    Int J Neural Syst; 2020 May; 30(5):2050020. PubMed ID: 32380925
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Eliciting dual-frequency SSVEP using a hybrid SSVEP-P300 BCI.
    Chang MH; Lee JS; Heo J; Park KS
    J Neurosci Methods; 2016 Jan; 258():104-13. PubMed ID: 26561770
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of Steady-State Visual Evoked Potential (SSVEP) with LCD vs. LED Stimulation.
    Mu J; Grayden DB; Tan Y; Oetomo D
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():2946-2949. PubMed ID: 33018624
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.